메뉴 건너뛰기




Volumn 119, Issue 2, 2012, Pages 272-277

Correlation between preoperative biometry and posterior chamber phakic visian Implantable Collamer Lens vaulting

Author keywords

[No Author keywords available]

Indexed keywords

ACHIEVED VAULT; ADULT; ANTERIOR LENS CAPSULE; ARTICLE; BIOMETRY; COMPARATIVE STUDY; COMPRESSION; CORNEA ENDOTHELIUM; CORRELATION ANALYSIS; CORRELATION COEFFICIENT; EXPECTED VAULT; FEMALE; HORIZONTAL SULCUS TO SULCUS DISTANCE; HORIZONTAL WHITE TO WHITE DISTANCE; HUMAN; IRIS; LENS IMPLANTATION; MAJOR CLINICAL STUDY; MALE; MYOPIA; PARAMETERS; PHAKIC INTRAOCULAR LENS; POSTERIOR EYE CHAMBER; POSTOPERATIVE PERIOD; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; RETROSPECTIVE STUDY; STEP WISE MULTIPLE REGRESSION; VAULT ERROR;

EID: 84856520300     PISSN: 01616420     EISSN: 15494713     Source Type: Journal    
DOI: 10.1016/j.ophtha.2011.07.047     Document Type: Article
Times cited : (109)

References (25)
  • 1
    • 67650462941 scopus 로고    scopus 로고
    • Four-year follow-up of posterior chamber phakic intraocular lens implantation for moderate to high myopia
    • K. Kamiya, K. Shimizu, A. Igarashi Four-year follow-up of posterior chamber phakic intraocular lens implantation for moderate to high myopia Arch Ophthalmol 127 2009 845 850
    • (2009) Arch Ophthalmol , vol.127 , pp. 845-850
    • Kamiya, K.1    Shimizu, K.2    Igarashi, A.3
  • 2
    • 34250634721 scopus 로고    scopus 로고
    • Matched population comparison of the visian implantable collamer lens and standard LASIK for myopia of -3.00 to -7.88 diopters
    • D.R. Sanders Matched population comparison of the Visian Implantable Collamer Lens and standard LASIK for myopia of -3.00 to -7.88 diopters J Refract Surg 23 2007 537 553 (Pubitemid 46932374)
    • (2007) Journal of Refractive Surgery , vol.23 , Issue.6 , pp. 537-553
    • Sanders, D.R.1
  • 3
    • 4444238096 scopus 로고    scopus 로고
    • United States Food and Drug Administration clinical trial of the Implantable Collamer Lens (ICL) for moderate to high myopia: Three-year follow-up
    • ICL in Treatment of Myopia (ITM) Study Group
    • ICL in Treatment of Myopia (ITM) Study Group United States Food and Drug Administration clinical trial of the Implantable Collamer Lens (ICL) for moderate to high myopia: three-year follow-up Ophthalmology 111 2004 1683 1692
    • (2004) Ophthalmology , vol.111 , pp. 1683-1692
  • 4
    • 0031779851 scopus 로고    scopus 로고
    • Posterior chamber phakic intraocular lens for myopia of -8 to -19 diopters
    • R. Zaldivar, J.M. Davidorf, S. Oscherow Posterior chamber phakic intraocular lens for myopia of -8 to -19 diopters J Refract Surg 14 1998 294 305 (Pubitemid 28265752)
    • (1998) Journal of Refractive Surgery , vol.14 , Issue.3 , pp. 294-305
    • Zaldivar, R.1    Davidorf, J.M.2    Oscherow, S.3
  • 5
    • 63449118736 scopus 로고    scopus 로고
    • Changes in iridocorneal angle structure and trabecular pigmentation with STAAR implantable collamer lens during 2 years
    • T.Y. Chung, S.C. Park, M.O. Lee Changes in iridocorneal angle structure and trabecular pigmentation with STAAR implantable collamer lens during 2 years J Refract Surg 25 2009 251 258
    • (2009) J Refract Surg , vol.25 , pp. 251-258
    • Chung, T.Y.1    Park, S.C.2    Lee, M.O.3
  • 6
    • 0035175152 scopus 로고    scopus 로고
    • Safety of posterior chamber phakic intraocular lenses for the correction of high myopia: Anterior segment changes after posterior chamber phakic intraocular lens implantation
    • DOI 10.1016/S0161-6420(00)00403-6, PII S0161642000004036
    • I. Jimenez-Alfaro, J.M. Benitez del Castillo, J. Garcia-Feijoo Safety of posterior chamber phakic intraocular lenses for the correction of high myopia: anterior segment changes after posterior chamber phakic intraocular lens implantation Ophthalmology 108 2001 90 99 (Pubitemid 32059541)
    • (2001) Ophthalmology , vol.108 , Issue.1 , pp. 90-99
    • Jimenez-Alfaro, I.1    Benitez Del Castillo, J.M.2    Garcia-Feijoo, J.3    Gil De Bernabe, J.G.4    Serrano De La Iglesia, J.M.5
  • 8
    • 33746286336 scopus 로고    scopus 로고
    • Cataractous Changes due to Posterior Chamber Flattening with a Posterior Chamber Phakic Intraocular Lens Secondary to the Administration of Pilocarpine
    • DOI 10.1016/j.ophtha.2006.03.053, PII S0161642006005513
    • M.J. Maldonado, J. Garcia-Feijoo, J.M. Benitez del Castillo, P. Teutsch Cataractous changes due to posterior chamber flattening with a posterior chamber phakic intraocular lens secondary to the administration of pilocarpine Ophthalmology 113 2006 1283 1288 (Pubitemid 44108193)
    • (2006) Ophthalmology , vol.113 , Issue.8 , pp. 1283-1288
    • Maldonado, M.J.1    Garcia-Feijoo, J.2    Benitez Del Castillo, J.M.3    Teutsch, P.4
  • 10
    • 45249119483 scopus 로고    scopus 로고
    • Anterior subcapsular opacities and cataracts 5 years after surgery in the Visian Implantable Collamer Lens FDA trial
    • D.R. Sanders Anterior subcapsular opacities and cataracts 5 years after surgery in the Visian Implantable Collamer Lens FDA trial J Refract Surg 24 2008 566 570 (Pubitemid 351842080)
    • (2008) Journal of Refractive Surgery , vol.24 , Issue.6 , pp. 566-570
    • Sanders, D.R.1
  • 11
    • 0036857084 scopus 로고    scopus 로고
    • Incidence of lens opacities and clinically significant cataracts with the implantable contact lens: Comparison of two lens designs
    • D.R. Sanders, J.A. Vukich ICL in Treatment of Myopia (ITM) Study Group Incidence of lens opacities and clinically significant cataracts with the implantable contact lens: comparison of two lens designs J Refract Surg 18 2002 673 682 (Pubitemid 35429193)
    • (2002) Journal of Refractive Surgery , vol.18 , Issue.6 , pp. 673-682
    • Sanders, D.R.1    Vukich, J.A.2    Smith, D.3
  • 12
    • 67349195991 scopus 로고    scopus 로고
    • Objective versus subjective vault measurement after myopic implantable collamer lens implantation
    • J.F. Alfonso, C. Lisa, A. Palacios Objective versus subjective vault measurement after myopic implantable collamer lens implantation Am J Ophthalmol 147 2009 978 983
    • (2009) Am J Ophthalmol , vol.147 , pp. 978-983
    • Alfonso, J.F.1    Lisa, C.2    Palacios, A.3
  • 13
    • 34247277737 scopus 로고    scopus 로고
    • Ultrasound biomicroscopy for determining Visian implantable contact lens length in phakic IOL implantation
    • K.H. Choi, S.E. Chung, T.Y. Chung, E.S. Chung Ultrasound biomicroscopy for determining Visian implantable contact lens length in phakic IOL implantation J Refract Surg 23 2007 362 367
    • (2007) J Refract Surg , vol.23 , pp. 362-367
    • Choi, K.H.1    Chung, S.E.2    Chung, T.Y.3    Chung, E.S.4
  • 14
    • 0043207749 scopus 로고    scopus 로고
    • Actual and theoretical risks for visual loss following use of the implantable contact lens for moderate to high myopia
    • DOI 10.1016/S0886-3350(02)02040-0
    • D.R. Sanders Actual and theoretical risks for visual loss following use of the implantable contact lens for moderate to high myopia J Cataract Refract Surg 29 2003 1323 1332 (Pubitemid 36935873)
    • (2003) Journal of Cataract and Refractive Surgery , vol.29 , Issue.7 , pp. 1323-1332
    • Sanders, D.R.1
  • 17
    • 0034907871 scopus 로고    scopus 로고
    • Predicting sulcus size using ocular measurements
    • DOI 10.1016/S0886-3350(00)00830-0, PII S0886335001008300
    • M. Pop, Y. Payette, M. Mansour Predicting sulcus size using ocular measurements J Cataract Refract Surg 27 2001 1033 1038 (Pubitemid 32734153)
    • (2001) Journal of Cataract and Refractive Surgery , vol.27 , Issue.7 , pp. 1033-1038
    • Pop, M.1    Payette, Y.2    Mansour, M.3
  • 18
    • 60849115870 scopus 로고    scopus 로고
    • Correlation of anterior chamber angle and ciliary sulcus diameters with white-to-white corneal diameter in high myopes using Artemis VHF digital ultrasound
    • D.Z. Reinstein, T.J. Archer, R.H. Silverman Correlation of anterior chamber angle and ciliary sulcus diameters with white-to-white corneal diameter in high myopes using Artemis VHF digital ultrasound J Refract Surg 25 2009 185 194
    • (2009) J Refract Surg , vol.25 , pp. 185-194
    • Reinstein, D.Z.1    Archer, T.J.2    Silverman, R.H.3
  • 19
    • 34548226462 scopus 로고    scopus 로고
    • Direct Measurement of the Ciliary Sulcus Diameter by 35-Megahertz Ultrasound Biomicroscopy
    • DOI 10.1016/j.ophtha.2006.12.018, PII S0161642006016678
    • J. Oh, H.H. Shin, J.H. Kim Direct measurement of the ciliary sulcus diameter by 35-megahertz ultrasound biomicroscopy Ophthalmology 114 2007 1685 1688 (Pubitemid 47332664)
    • (2007) Ophthalmology , vol.114 , Issue.9 , pp. 1685-1688
    • Oh, J.1    Shin, H.-H.2    Kim, J.-H.3    Kim, H.-M.4    Song, J.-S.5
  • 20
    • 63449134268 scopus 로고    scopus 로고
    • Factors affecting vaulting after implantable collamer lens implantation
    • K. Kamiya, K. Shimizu, M. Komatsu Factors affecting vaulting after implantable collamer lens implantation J Refract Surg 25 2009 259 264
    • (2009) J Refract Surg , vol.25 , pp. 259-264
    • Kamiya, K.1    Shimizu, K.2    Komatsu, M.3
  • 21
    • 77955466368 scopus 로고    scopus 로고
    • Long-term changes in posterior chamber phakic intraocular collamer lens vaulting in myopic patients
    • G. Schmidinger, B. Lackner, S. Pieh, C. Skorpik Long-term changes in posterior chamber phakic intraocular collamer lens vaulting in myopic patients Ophthalmology 117 2010 1506 1511
    • (2010) Ophthalmology , vol.117 , pp. 1506-1511
    • Schmidinger, G.1    Lackner, B.2    Pieh, S.3    Skorpik, C.4
  • 22
    • 33750444898 scopus 로고    scopus 로고
    • Anterior segment OCT and phakic intraocular lenses: A perspective
    • DOI 10.1016/j.jcrs.2006.08.025, PII S0886335006011175
    • G. Baikoff Anterior segment OCT and phakic intraocular lenses: a perspective J Cataract Refract Surg 32 2006 1827 1835 (Pubitemid 44647791)
    • (2006) Journal of Cataract and Refractive Surgery , vol.32 , Issue.11 , pp. 1827-1835
    • Baikoff, G.1
  • 23
    • 35548944505 scopus 로고    scopus 로고
    • Optical Coherence Tomography of the Anterior Segment in Eyes with Phakic Refractive Lenses
    • DOI 10.1016/j.ophtha.2007.06.020, PII S0161642007007178
    • A. Koivula, M. Kugelberg Optical coherence tomography of the anterior segment in eyes with phakic refractive lenses Ophthalmology 114 2007 2031 2037 (Pubitemid 350016380)
    • (2007) Ophthalmology , vol.114 , Issue.11 , pp. 2031-2037
    • Koivula, A.1    Kugelberg, M.2
  • 24
    • 1642271534 scopus 로고    scopus 로고
    • Comparison of manual and automated methods to determine horizontal corneal diameter
    • DOI 10.1016/j.jcrs.2003.06.004, PII S0886335003007211
    • M. Baumeister, E. Terzi, Y. Ekici, T. Kohnen Comparison of manual and automated methods to determine horizontal corneal diameter J Cataract Refract Surg 30 2004 374 380 (Pubitemid 38366363)
    • (2004) Journal of Cataract and Refractive Surgery , vol.30 , Issue.2 , pp. 374-380
    • Baumeister, M.1    Terzi, E.2    Ekici, Y.3    Kohnen, T.4
  • 25
    • 69449103836 scopus 로고    scopus 로고
    • Comparison of horizontal corneal diameter measurements using Galilei, EyeSys and Orbscan II systems
    • R. Salouti, M.H. Nowroozzadeh, M. Zamani, M. Ghoreyshi Comparison of horizontal corneal diameter measurements using Galilei, EyeSys and Orbscan II systems Clin Exp Optom 92 2009 429 433
    • (2009) Clin Exp Optom , vol.92 , pp. 429-433
    • Salouti, R.1    Nowroozzadeh, M.H.2    Zamani, M.3    Ghoreyshi, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.