메뉴 건너뛰기




Volumn 20, Issue 3, 2012, Pages 2681-2692

Dual-beam-scan Doppler optical coherence angiography for birefringence-artifact-free vasculature imaging

Author keywords

[No Author keywords available]

Indexed keywords

ANGIOGRAPHY; HISTOLOGY; POLARIZATION; TISSUE;

EID: 84856484013     PISSN: None     EISSN: 10944087     Source Type: Journal    
DOI: 10.1364/OE.20.002681     Document Type: Article
Times cited : (7)

References (32)
  • 3
    • 0000063298 scopus 로고    scopus 로고
    • In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomography
    • J. A. Izatt, M. D. Kulkarni, S. Yazdanfar, J. K. Barton, and A. J. Welch, "In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomography," Opt. Lett. 22, 1439-1441(1997). (Pubitemid 127565229)
    • (1997) Optics Letters , vol.22 , Issue.18 , pp. 1439-1441
    • Izatt, J.A.1    Kulkarni, M.D.2    Yazdanfar, S.3    Barton, J.K.4    Welch, A.J.5
  • 4
    • 2942703836 scopus 로고    scopus 로고
    • Real-time assessment of retinal blood flow with ultrafast acquisition by color Doppler Fourier domain optical coherence tomography
    • R. Leitgeb, L. Schmetterer, W. Drexler, A. Fercher, R. Zawadzki, and T. Bajraszewski, "Real-time assessment of retinal blood flow with ultrafast acquisition by color Doppler Fourier domain optical coherence tomography," Opt. Express 11, 3116-3121(2003).
    • (2003) Opt. Express , vol.11 , pp. 3116-3121
    • Leitgeb, R.1    Schmetterer, L.2    Drexler, W.3    Fercher, A.4    Zawadzki, R.5    Bajraszewski, T.6
  • 6
    • 33747769290 scopus 로고    scopus 로고
    • Optical coherence angiography
    • DOI 10.1364/OE.14.007821
    • S. Makita, Y. Hong, M. Yamanari, T. Yatagai, and Y. Yasuno, "Optical coherence angiography," Opt. Express 14, 7821-7840(2006). (Pubitemid 44277517)
    • (2006) Optics Express , vol.14 , Issue.17 , pp. 7821-7840
    • Makita, S.1    Hong, Y.2    Yamanari, M.3    Yatagai, T.4    Yasuno, Y.5
  • 7
    • 34548454570 scopus 로고    scopus 로고
    • Mapping of cerebro-vascular blood perfusion in mice with skin and skull intact by Optical Micro-AngioGraphy at 1.3μm wavelength
    • DOI 10.1364/OE.15.011402
    • R. K. Wang and S. Hurst, "Mapping of cerebro-vascular blood perfusion in mice with skin and skull intact by optical micro-angiography at 1.3 μm wavelength," Opt. Express 15, 11402-11412(2007). (Pubitemid 47360576)
    • (2007) Optics Express , vol.15 , Issue.18 , pp. 11402-11412
    • Wang, R.K.1    Hurst, S.2
  • 8
    • 43049093773 scopus 로고    scopus 로고
    • Flow velocity estimation using joint Spectral and Time domain Optical Coherence Tomography
    • DOI 10.1364/OE.16.006008
    • M. Szkulmowski, A. Szkulmowska, T. Bajraszewski, A. Kowalczyk, and M. Wojtkowski, "Flow velocity estimation using joint spectral and time domain optical coherence tomography," Opt. Express 16, 6008-6025(2008). (Pubitemid 351623313)
    • (2008) Optics Express , vol.16 , Issue.9 , pp. 6008-6025
    • Szkulmowski, M.1    Szkulmowska, A.2    Bajraszewski, T.3    Kowalczyk, A.4    Wojtkowski, M.5
  • 9
    • 49149121261 scopus 로고    scopus 로고
    • Single-pass volumetric bidirectional blood flow imaging spectral domain optical coherence tomography using a modified hilbert transform
    • Y. K. Tao, A. M. Davis, and J. A. Izatt, "Single-pass volumetric bidirectional blood flow imaging spectral domain optical coherence tomography using a modified hilbert transform," Opt. Express 16, 12350-12361(2008).
    • (2008) Opt. Express , vol.16 , pp. 12350-12361
    • Tao, Y.K.1    Davis, A.M.2    Izatt, J.A.3
  • 12
    • 72449129943 scopus 로고    scopus 로고
    • Volumetric microvascular imaging of human retina using optical coherence tomography with a novel motion contrast technique
    • J. Fingler, R. J. Zawadzki, J. S. Werner, D. Schwartz, and S. E. Fraser, "Volumetric microvascular imaging of human retina using optical coherence tomography with a novel motion contrast technique," Opt. Express 17, 22190-22200(2009).
    • (2009) Opt. Express , vol.17 , pp. 22190-22200
    • Fingler, J.1    Zawadzki, R.J.2    Werner, J.S.3    Schwartz, D.4    Fraser, S.E.5
  • 13
    • 77954714473 scopus 로고    scopus 로고
    • Depth-resolved imaging of capillary networks in retina and choroid using ultrahigh sensitive optical microangiography
    • R. K. Wang, L. An, P. Francis, and D. J. Wilson, "Depth-resolved imaging of capillary networks in retina and choroid using ultrahigh sensitive optical microangiography," Opt. Lett. 35, 1467-1469(2010).
    • (2010) Opt. Lett. , vol.35 , pp. 1467-1469
    • Wang, R.K.1    An, L.2    Francis, P.3    Wilson, D.J.4
  • 14
    • 84856464872 scopus 로고    scopus 로고
    • In vivo volumetric imaging of human retinal circulation with phase-variance optical coherence tomography
    • D. Y. Kim, J. Fingler, J. S. Werner, D. M. Schwartz, S. E. Fraser, and R. J. Zawadzki, "In vivo volumetric imaging of human retinal circulation with phase-variance optical coherence tomography," Biomed. Opt. Express 2, 1504-1513(2011).
    • (2011) Biomed. Opt. Express , vol.2 , pp. 1504-1513
    • Kim, D.Y.1    Fingler, J.2    Werner, J.S.3    Schwartz, D.M.4    Fraser, S.E.5    Zawadzki, R.J.6
  • 15
    • 78751519380 scopus 로고    scopus 로고
    • Comprehensive in vivo micro-vascular imaging of the human eye by dual-beam-scan Doppler optical coherence angiography
    • S. Makita, F. Jaillon, M. Yamanari, M. Miura, and Y. Yasuno, "Comprehensive in vivo micro-vascular imaging of the human eye by dual-beam-scan Doppler optical coherence angiography," Opt. Express 19, 1271-1283(2011).
    • (2011) Opt. Express , vol.19 , pp. 1271-1283
    • Makita, S.1    Jaillon, F.2    Yamanari, M.3    Miura, M.4    Yasuno, Y.5
  • 17
    • 79961161181 scopus 로고    scopus 로고
    • Enhanced imaging of choroidal vasculature by high-penetration and dual-velocity optical coherence angiography
    • F. Jaillon, S. Makita, E. J. Min, B. H. Lee, and Y. Yasuno, "Enhanced imaging of choroidal vasculature by high-penetration and dual-velocity optical coherence angiography," Biomed. Opt. Express 2, 1147-1158(2011).
    • (2011) Biomed. Opt. Express , vol.2 , pp. 1147-1158
    • Jaillon, F.1    Makita, S.2    Min, E.J.3    Lee, B.H.4    Yasuno, Y.5
  • 18
    • 0000071379 scopus 로고    scopus 로고
    • Light scattering and form birefringence of parallel cylindrical arrays that represent cellular organelles of the retinal nerve fiber layer
    • Q. Zhou and R. W. Knighton, "Light scattering and form birefringence of parallel cylindrical arrays that represent cellular organelles of the retinal nerve fiber layer," Appl. Opt. 36, 2273-2285(1997). (Pubitemid 127625417)
    • (1997) Applied Optics , vol.36 , Issue.10 , pp. 2273-2285
    • Zhou, Q.1    Knighton, R.W.2
  • 20
    • 33751331248 scopus 로고    scopus 로고
    • Quantification of the wound healing using polarization-sensitive optical coherence tomography
    • J. T. Oh, S. W. Lee, Y. S. Kim, K. B. Suhr, and B. M. Kim, "Quantification of the wound healing using polarization-sensitive optical coherence tomography," J. Biomed. Opt. 11, 041124(2006).
    • (2006) J. Biomed. Opt. , vol.11 , pp. 041124
    • Oh, J.T.1    Lee, S.W.2    Kim, Y.S.3    Suhr, K.B.4    Kim, B.M.5
  • 22
    • 33745873723 scopus 로고    scopus 로고
    • Fiber-based polarization-sensitive Fourier domain optical coherence tomography using B-scan-oriented polarization modulation method
    • DOI 10.1364/OE.14.006502
    • M. Yamanari, S. Makita, V. Madjarova, T. Yatagai, and Y. Yasuno, "Fiber-based polarization-sensitive Fourier domain optical coherence tomography using B-scan-oriented polarization modulation method," Opt. Express 14, 6502-6515(2006). (Pubitemid 44036384)
    • (2006) Optics Express , vol.14 , Issue.14 , pp. 6502-6515
    • Yamanari, M.1    Makita, S.2    Madjarova, V.D.3    Yatagai, T.4    Yasuno, Y.5
  • 23
    • 0036629489 scopus 로고    scopus 로고
    • Jones-matrix imaging of biological tissues with quadruple-channel optical coherence tomography
    • S. Jiao and L. V. Wang, "Jones-matrix imaging of biological tissues with quadruple-channel optical coherence tomography," J. Biomed. Opt. 7, 350-358(2002).
    • (2002) J. Biomed. Opt. , vol.7 , pp. 350-358
    • Jiao, S.1    Wang, L.V.2
  • 25
    • 47549090614 scopus 로고    scopus 로고
    • Phase-resolved Doppler optical coherence tomography-limitations and improvements
    • A. Szkulmowska, M. Szkulmowski, A. Kowalczyk, and M. Wojtkowski, "Phase-resolved Doppler optical coherence tomography-limitations and improvements," Opt. Lett. 33, 1425-1427(2008).
    • (2008) Opt. Lett. , vol.33 , pp. 1425-1427
    • Szkulmowska, A.1    Szkulmowski, M.2    Kowalczyk, A.3    Wojtkowski, M.4
  • 26
    • 0014374770 scopus 로고
    • Selective atrophy of the radial peripapillary capillaries in chronic glaucoma
    • A. L. Kornzweig, I. Eliasoph, and M. Feldstein, "Selective atrophy of the radial peripapillary capillaries in chronic glaucoma," Arch. Ophthalmol. 80, 696-702(1968).
    • (1968) Arch. Ophthalmol. , vol.80 , pp. 696-702
    • Kornzweig, A.L.1    Eliasoph, I.2    Feldstein, M.3
  • 27
    • 0014236399 scopus 로고
    • Radial peripapillary capillaries of the retina. II. Possible role in Bjerrum scotoma
    • M. Alterman and P. Henkind, "Radial peripapillary capillaries of the retina. II. Possible role in Bjerrum scotoma," Br. J. Ophthalmol. 52, 26-31(1968).
    • (1968) Br. J. Ophthalmol. , vol.52 , pp. 26-31
    • Alterman, M.1    Henkind, P.2
  • 28
    • 0033858678 scopus 로고    scopus 로고
    • Effect of corneal polarization axis on assessment of retinal nerve fiber layer thickness by scanning laser polarimetry
    • DOI 10.1016/S0002-9394(00)00353-6, PII S0002939400003536
    • D. S. Greenfield, R. W. Knighton, and X. R. Huang, "Effect of corneal polarization axis on assessment of retinal nerve fiber layer thickness by scanning laser polarimetry," Am. J. Ophthalmol. 129, 715-722(2000). (Pubitemid 30604148)
    • (2000) American Journal of Ophthalmology , vol.129 , Issue.6 , pp. 715-722
    • Greenfield, D.S.1    Knighton, R.W.2    Huang, X.-R.3
  • 29
    • 0032606424 scopus 로고    scopus 로고
    • Differential phase contrast in optical coherence tomography
    • C. K. Hitzenberger and A. F. Fercher, "Differential phase contrast in optical coherence tomography," Opt. Lett. 24, 622-624(1999). (Pubitemid 129306881)
    • (1999) Optics Letters , vol.24 , Issue.9 , pp. 622-624
    • Hitzenberger, C.K.1    Fercher, A.F.2
  • 30
    • 0001545734 scopus 로고    scopus 로고
    • Optical low-coherence reflectometer for differential phase measurement
    • D. P. Davé and T. E. Milner, "Optical low-coherence reflectometer for differential phase measurement," Opt. Lett. 25, 227-229(2000). (Pubitemid 33638828)
    • (2000) Optics Letters , vol.25 , Issue.4 , pp. 227-229
    • Dave, D.P.1    Milner, T.E.2
  • 31
    • 0347093548 scopus 로고    scopus 로고
    • Differential phase optical coherence probe for depth-resolved detection of photothermal response in tissue
    • DOI 10.1088/0031-9155/49/1/008, PII S0031915504670412
    • S. A. Telenkov, D. P. Dave, S. Sethuraman, T. Akkin, and T. E. Milner, "Differential phase optical coherence probe for depth-resolved detection of photothermal response in tissue," Phys. Med. Biol. 49, 111-119(2004). (Pubitemid 38100626)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.1 , pp. 111-119
    • Telenkov, S.A.1    Dave, D.P.2    Sethuraman, S.3    Akkin, T.4    Milner, T.E.5
  • 32
    • 78650815307 scopus 로고    scopus 로고
    • Sample motion-insensitive, full-range, complex, spectral-domain optical-coherence tomography
    • S. Zotter, M. Pircher, E. Götzinger, T. Torzicky, M. Bonesi, and C. K. Hitzenberger, "Sample motion-insensitive, full-range, complex, spectral-domain optical-coherence tomography," Opt. Lett. 35, 3913-3915(2010).
    • (2010) Opt. Lett. , vol.35 , pp. 3913-3915
    • Zotter, S.1    Pircher, M.2    Götzinger, E.3    Torzicky, T.4    Bonesi, M.5    Hitzenberger, C.K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.