메뉴 건너뛰기




Volumn 40, Issue 1, 2012, Pages 142-149

Ventilator versus manual hyperinflation in clearing sputum in ventilated intensive care unit patients

Author keywords

Hyperventilation; Intensive care; Manual; Sputum removal; Ventilation; Ventilator

Indexed keywords

ADULT; AGED; AIRWAY PRESSURE; ARTERIAL OXYGEN TENSION; ARTICLE; ARTIFICIAL VENTILATION; BLOOD OXYGENATION; BREATHING RATE; CLINICAL ARTICLE; CLINICAL PROTOCOL; CONTROLLED STUDY; CROSSOVER PROCEDURE; FEMALE; HEART RATE; HUMAN; HYPERINFLATION; INTENSIVE CARE UNIT; LUNG COLLAPSE; LUNG COMPLIANCE; MALE; MANUAL HYPERINFLATION; MEAN ARTERIAL PRESSURE; OUTCOME ASSESSMENT; PHYSIOTHERAPY; RANDOMIZED CONTROLLED TRIAL; SPUTUM; SPUTUM REMOVAL; TERTIARY HEALTH CARE; TIDAL VOLUME; VENTILATED PATIENT; VENTILATOR;

EID: 84856466006     PISSN: 0310057X     EISSN: 14480271     Source Type: Journal    
DOI: 10.1177/0310057x1204000117     Document Type: Article
Times cited : (43)

References (12)
  • 1
    • 0033641579 scopus 로고    scopus 로고
    • Manual hyperinflation - Effects on respiratory parameters
    • Patman S, Jenkins S, Stiller K. Manual hyperinflation - effects on respiratory parameters. Physiother Res Int 2000; 5:157-171.
    • (2000) Physiother Res Int , vol.5 , pp. 157-171
    • Patman, S.1    Jenkins, S.2    Stiller, K.3
  • 2
    • 0032884899 scopus 로고    scopus 로고
    • A survey of manual hyperinflation in Australian hospitals
    • Hodgson C, Carroll S, Denehy L. A survey of manual hyperinflation in Australian hospitals. Aust J Physiother 1999; 45:185-193.
    • (1999) Aust J Physiother , vol.45 , pp. 185-193
    • Hodgson, C.1    Carroll, S.2    Denehy, L.3
  • 3
    • 0036050944 scopus 로고    scopus 로고
    • A comparison of the effects of manual and ventilator hyperinflation on static lung compliance and sputum production in intubated and ventilated intensive care patients
    • Berney S, Denehy L. A comparison of the effects of manual and ventilator hyperinflation on static lung compliance and sputum production in intubated and ventilated intensive care patients. Physiother Res Int 2002; 7:100-108.
    • (2002) Physiother Res Int , vol.7 , pp. 100-108
    • Berney, S.1    Denehy, L.2
  • 4
    • 33748305651 scopus 로고    scopus 로고
    • Comparison of the effectiveness of manual and ventilator hyperinflation at different levels of positive end-expiratory pressure in artificially ventilated and intubated intensive care patients
    • Savian C, Paratz J, Davies A. Comparison of the effectiveness of manual and ventilator hyperinflation at different levels of positive end-expiratory pressure in artificially ventilated and intubated intensive care patients. Heart Lung 2006; 35:334-341.
    • (2006) Heart Lung , vol.35 , pp. 334-341
    • Savian, C.1    Paratz, J.2    Davies, A.3
  • 5
    • 72649101564 scopus 로고    scopus 로고
    • Hyperinflation using pressure support ventilation improves secretion clearance and respiratory mechanics in ventilated patients with pulmonary infection: A randomised crossover trial
    • Lemes DA, Zin WA, Guimaraes FS. Hyperinflation using pressure support ventilation improves secretion clearance and respiratory mechanics in ventilated patients with pulmonary infection: a randomised crossover trial. Aust J Physiother 2009; 55:249-254.
    • (2009) Aust J Physiother , vol.55 , pp. 249-254
    • Lemes, D.A.1    Zin, W.A.2    Guimaraes, F.S.3
  • 6
    • 79953022854 scopus 로고    scopus 로고
    • A survey of the use of ventilator hyperinflation in Australian tertairy intensive care units
    • Dennis DM, Jacob WJ, Samuel FD. A survey of the use of ventilator hyperinflation in Australian tertairy intensive care units. Crit Care Resusc 2010; 12:262-268.
    • (2010) Crit Care Resusc , vol.12 , pp. 262-268
    • Dennis, D.M.1    Jacob, W.J.2    Samuel, F.D.3
  • 8
    • 33947112459 scopus 로고    scopus 로고
    • The Mapleson C circuit clears more secretions than the Laerdal circuit during manual hyperinflation in mechanically-ventilated patients: A randomised cross-over trial
    • Hodgson C, Ntoumenopoulos G, Dawson H, Paratz J. The Mapleson C circuit clears more secretions than the Laerdal circuit during manual hyperinflation in mechanically-ventilated patients: a randomised cross-over trial. Aust J Physiother 2007; 53:33-38.
    • (2007) Aust J Physiother , vol.53 , pp. 33-38
    • Hodgson, C.1    Ntoumenopoulos, G.2    Dawson, H.3    Paratz, J.4
  • 9
    • 15344348485 scopus 로고    scopus 로고
    • Effects of manual hyperinflation and suctioning in respiratory mechanics in mechanically ventilated patients with ventilator-associated pneumonia
    • Choi JS, Jones AY. Effects of manual hyperinflation and suctioning in respiratory mechanics in mechanically ventilated patients with ventilator-associated pneumonia. Aust J Physiother 2005; 51:25-30.
    • (2005) Aust J Physiother , vol.51 , pp. 25-30
    • Choi, J.S.1    Jones, A.Y.2
  • 10
    • 79957849315 scopus 로고    scopus 로고
    • A randomised controlled trial of an open lung strategy with staircase recruitment, titrated PEEP and targeted low airway pressures in patients with acute respiratory distress syndrome
    • Hodgson CL, Tuxen DV, Davies AR, Bailey MJ, Higgins AM, Holland AE et al. A randomised controlled trial of an open lung strategy with staircase recruitment, titrated PEEP and targeted low airway pressures in patients with acute respiratory distress syndrome. Crit Care 2011; 15:R133.
    • (2011) Crit Care , vol.15
    • Hodgson, C.L.1    Tuxen, D.V.2    Davies, A.R.3    Bailey, M.J.4    Higgins, A.M.5    Holland, A.E.6
  • 11
    • 67649390754 scopus 로고    scopus 로고
    • Manual hyperinflation of intubated and mechanically ventilated patients in Dutch intensive care units - A survey into current practice and knowledge
    • Paulus F, Binnekade JM, Middelhoek P, Schuitz MJ, Vroom MB. Manual hyperinflation of intubated and mechanically ventilated patients in Dutch intensive care units - a survey into current practice and knowledge. Intensive Crit Care Nurs 2009; 25:199-207.
    • (2009) Intensive Crit Care Nurs , vol.25 , pp. 199-207
    • Paulus, F.1    Binnekade, J.M.2    Middelhoek, P.3    Schuitz, M.J.4    Vroom, M.B.5
  • 12
    • 68449092753 scopus 로고    scopus 로고
    • Performance of manual hyperinflation: A skills lab study among trained intensive care unit nurses
    • Paulus F, Binnekade JM, Middelhoek P, Vroom MB, Schultz MJ. Performance of manual hyperinflation: a skills lab study among trained intensive care unit nurses. Med Sci Monit 2009; 15:CR418-242.
    • (2009) Med Sci Monit , vol.15
    • Paulus, F.1    Binnekade, J.M.2    Middelhoek, P.3    Vroom, M.B.4    Schultz, M.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.