메뉴 건너뛰기




Volumn 20, Issue 3, 2012, Pages 3082-3090

Enhancement of photoacoustic image quality by sound speed correction: Ex vivo evaluation

Author keywords

[No Author keywords available]

Indexed keywords

IMAGE QUALITY; OPTIMIZATION; SPEED; TISSUE;

EID: 84856444218     PISSN: None     EISSN: 10944087     Source Type: Journal    
DOI: 10.1364/OE.20.003082     Document Type: Article
Times cited : (71)

References (17)
  • 1
    • 33746152397 scopus 로고    scopus 로고
    • Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging
    • DOI 10.1038/nbt1220, PII NBT1220
    • H. F. Zhang, K. Maslov, G. Stoica, and L. V. Wang, "Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging," Nat. Biotechnol. 24(7), 848-851(2006). (Pubitemid 44086627)
    • (2006) Nature Biotechnology , vol.24 , Issue.7 , pp. 848-851
    • Zhang, H.F.1    Maslov, K.2    Stoica, G.3    Wang, L.V.4
  • 3
    • 33646434247 scopus 로고    scopus 로고
    • Photoacoustic imaging in biomedicine
    • M. Xu and L. V. Wang, "Photoacoustic imaging in biomedicine," Rev. Sci. Instrum. 77(4), 0411011(2006).
    • (2006) Rev. Sci. Instrum. , vol.77 , Issue.4 , pp. 0411011
    • Xu, M.1    Wang, L.V.2
  • 5
    • 79851514551 scopus 로고    scopus 로고
    • Photoacoustic imaging with a commercial ultrasound system and a custom probe
    • X. Wang, J. B. Fowlkes, J. M. Cannata, C. Hu, and P. L. Carson, "Photoacoustic imaging with a commercial ultrasound system and a custom probe," Ultrasound Med. Biol. 37(3), 484-492(2011).
    • (2011) Ultrasound Med. Biol. , vol.37 , Issue.3 , pp. 484-492
    • Wang, X.1    Fowlkes, J.B.2    Cannata, J.M.3    Hu, C.4    Carson, P.L.5
  • 6
    • 80054085825 scopus 로고    scopus 로고
    • The applicability of ultrasound dynamic receive beamformers to photoacoustic imaging
    • T. Harrison and R. J. Zemp, "The applicability of ultrasound dynamic receive beamformers to photoacoustic imaging," IEEE Trans. Ultrason. Ferroelectr. Freq. Control 58(10), 2259-2263(2011).
    • (2011) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.58 , Issue.10 , pp. 2259-2263
    • Harrison, T.1    Zemp, R.J.2
  • 7
    • 9144245647 scopus 로고    scopus 로고
    • Optoacoustic imaging with synthetic aperture focusing and coherence weighting
    • C.-K. Liao, M.-L. Li, and P.-C. Li, "Optoacoustic imaging with synthetic aperture focusing and coherence weighting," Opt. Lett. 29(21), 2506-2508(2004).
    • (2004) Opt. Lett. , vol.29 , Issue.21 , pp. 2506-2508
    • Liao, C.-K.1    Li, M.-L.2    Li, P.-C.3
  • 8
    • 46149114613 scopus 로고    scopus 로고
    • Adaptive beamforming for photoacoustic imaging
    • S. Park, A. B. Karpiouk, S. R. Aglyamov, and S. Y. Emelianov, "Adaptive beamforming for photoacoustic imaging," Opt. Lett. 33(12), 1291-1293(2008).
    • (2008) Opt. Lett. , vol.33 , Issue.12 , pp. 1291-1293
    • Park, S.1    Karpiouk, A.B.2    Aglyamov, S.R.3    Emelianov, S.Y.4
  • 9
    • 79957990376 scopus 로고    scopus 로고
    • In vitro estimation of mean sound speed based on minimum average phase variance in medical ultrasound imaging
    • C. Yoon, Y. Lee, J. H. Chang, T.-K. Song, and Y. Yoo, "In vitro estimation of mean sound speed based on minimum average phase variance in medical ultrasound imaging," Ultrasonics 51(7), 795-802(2011).
    • (2011) Ultrasonics , vol.51 , Issue.7 , pp. 795-802
    • Yoon, C.1    Lee, Y.2    Chang, J.H.3    Song, T.-K.4    Yoo, Y.5
  • 10
    • 80052539242 scopus 로고    scopus 로고
    • Automatic sound speed selection in photoacoustic image reconstruction using an autofocus approach
    • B. E. Treeby, T. K. Varslot, E. Z. Zhang, J. G. Laufer, and P. C. Beard, "Automatic sound speed selection in photoacoustic image reconstruction using an autofocus approach," J. Biomed. Opt. 16(9), 090501(2011).
    • (2011) J. Biomed. Opt. , vol.16 , Issue.9 , pp. 090501
    • Treeby, B.E.1    Varslot, T.K.2    Zhang, E.Z.3    Laufer, J.G.4    Beard, P.C.5
  • 11
    • 33947386610 scopus 로고    scopus 로고
    • Reflection mode photoacoustic measurement of speed of sound
    • DOI 10.1364/OE.15.003291
    • R. G. M. Kolkman, W. Steenbergen, and T. G. van Leeuwen, "Reflection mode photoacoustic measurement of speed of sound," Opt. Express 15(6), 3291-3300(2007). (Pubitemid 46457195)
    • (2007) Optics Express , vol.15 , Issue.6 , pp. 3291-3300
    • Kolkman, R.G.M.1    Steenbergen, W.2    Van Leeuwen, T.G.3
  • 12
    • 0038137178 scopus 로고    scopus 로고
    • Two-dimensional photoacoustic imaging by use of Fourier-transform image reconstruction and a detector with an anisotropic response
    • K. P. Köstli and P. C. Beard, "Two-dimensional photoacoustic imaging by use of Fourier-transform image reconstruction and a detector with an anisotropic response," Appl. Opt. 42(10), 1899-1908(2003).
    • (2003) Appl. Opt. , vol.42 , Issue.10 , pp. 1899-1908
    • Köstli, K.P.1    Beard, P.C.2
  • 13
    • 77956640945 scopus 로고    scopus 로고
    • κ-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields
    • B. E. Treeby and B. T. Cox, "κ-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields," J. Biomed. Opt. 15(2), 021314(2010).
    • (2010) J. Biomed. Opt. , vol.15 , Issue.2 , pp. 021314
    • Treeby, B.E.1    Cox, B.T.2
  • 14
    • 80055021249 scopus 로고    scopus 로고
    • Optimal laser wavelength for photoacoustic imaging of breast microcalcification
    • J. Kang, E. K. Kim, J. Y. Kwak, Y. Yoo, T.-K. Song, and J. H. Chang, "Optimal laser wavelength for photoacoustic imaging of breast microcalcification," Appl. Phys. Lett. 99(15), 153702(2011).
    • (2011) Appl. Phys. Lett. , vol.99 , Issue.15 , pp. 153702
    • Kang, J.1    Kim, E.K.2    Kwak, J.Y.3    Yoo, Y.4    Song, T.-K.5    Chang, J.H.6
  • 16
    • 0024111013 scopus 로고
    • Phase-aberration correction using signals from point reflector and diffuse scatterers: Basic principles
    • S. W. Flax and M. O'Donnell, "Phase-aberration correction using signals from point reflector and diffuse scatterers: basic principles," IEEE Trans. Ultrason. Ferroelectr. Freq. Control 35(6), 758-767(1988).
    • (1988) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.35 , Issue.6 , pp. 758-767
    • Flax, S.W.1    O'Donnell, M.2
  • 17
    • 77953265743 scopus 로고    scopus 로고
    • Wiener beamforming and the coherence factor in ultrasound imaging
    • C. I. Nilsen and S. Holm, "Wiener beamforming and the coherence factor in ultrasound imaging," IEEE Trans. Ultrason. Ferroelectr. Freq. Control 57(6), 1329-1346(2010).
    • (2010) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.57 , Issue.6 , pp. 1329-1346
    • Nilsen, C.I.1    Holm, S.2