메뉴 건너뛰기




Volumn 202, Issue 4, 2011, Pages 404-408

Hypotension is 100 mm Hg on the battlefield

Author keywords

Base deficit; Combat; Hypotension; Mortality; Shock; Systolic blood pressure; Trauma

Indexed keywords

ACIDOSIS; ARMY; ARTICLE; BATTLE INJURY; CONTROLLED STUDY; DATA ANALYSIS; DISEASE REGISTRY; HUMAN; HYPOTENSION; MAJOR CLINICAL STUDY; MEDICAL RECORD REVIEW; MILITARY MEDICINE; MORTALITY; PERFUSION; PRIORITY JOURNAL; SYSTOLIC BLOOD PRESSURE; UNITED STATES; INJURY; REGISTER; RETROSPECTIVE STUDY; SYSTOLE; WAR;

EID: 84856367065     PISSN: 00029610     EISSN: 18791883     Source Type: Journal    
DOI: 10.1016/j.amjsurg.2010.10.012     Document Type: Article
Times cited : (48)

References (21)
  • 2
    • 43349088258 scopus 로고    scopus 로고
    • Injury severity and causes of death from operation Iraqi freedom and operation enduring freedom: 2003-2004 versus 2006
    • Kelly JF, Ritenour AE, McLaughlin DF, et al. Injury severity and causes of death from Operation Iraqi Freedom and Operation Enduring Freedom: 2003-2004 versus 2006. J Trauma 2008;64:S21-6.
    • (2008) J Trauma , vol.64
    • Kelly, J.F.1    Ritenour, A.E.2    McLaughlin, D.F.3
  • 3
    • 43349087466 scopus 로고    scopus 로고
    • A predictive model for massive transfusion in combat casualty patients
    • McLaughlin DF, Niles SE, Salinas J, et al. A predictive model for massive transfusion in combat casualty patients. J Trauma 2008;64: S57-63.
    • (2008) J Trauma , vol.64
    • McLaughlin, D.F.1    Niles, S.E.2    Salinas, J.3
  • 6
    • 34547854414 scopus 로고    scopus 로고
    • Hypotension begins at 110 mm Hg: Redefining "hypotension," with data
    • Eastridge BJ, Salinas J, McManus JG, et al. Hypotension begins at 110 mm Hg: redefining "hypotension" with data. J Trauma 2007;63:291-9.
    • (2007) J Trauma , vol.63 , pp. 291-299
    • Eastridge, B.J.1    Salinas, J.2    McManus, J.G.3
  • 7
    • 0023752119 scopus 로고
    • Central venous blood oxygen saturation: An early, accurate measurement of volume during hemorrhage
    • Scalea TM, Holman M, Fuortes M, et al. Central venous blood oxygen saturation: an early, accurate measurement of volume during hemorrhage. J Trauma 1988;28:725-32.
    • (1988) J Trauma , vol.28 , pp. 725-732
    • Scalea, T.M.1    Holman, M.2    Fuortes, M.3
  • 9
    • 33748750333 scopus 로고    scopus 로고
    • Arterial pulse pressure and its association with reduced stroke volume during progressive central hypovolemia
    • DOI 10.1097/01.ta.0000196663.34175.33, PII 0000537320060900000018
    • Convertino VA, Cooke W, Holcomb JB. Arterial pulse pressure and its association with reduced stroke volume during progressive central hypovolemia. J Trauma 2006;61:629-34. (Pubitemid 44400946)
    • (2006) Journal of Trauma - Injury, Infection and Critical Care , vol.61 , Issue.3 , pp. 629-634
    • Convertino, V.A.1    Cooke, W.H.2    Holcomb, J.B.3
  • 11
    • 0028896078 scopus 로고
    • Do prehospital trauma center triage criteria identify major trauma victims?
    • Esposito TJ, Offner PJ, Jurkovich GJ, et al. Do prehospital trauma center triage criteria identify major trauma victims? Arch Surg 1995; 130:171-6.
    • (1995) Arch Surg , vol.130 , pp. 171-176
    • Esposito, T.J.1    Offner, P.J.2    Jurkovich, G.J.3
  • 13
    • 0025273312 scopus 로고
    • Early physiologic predictors of injury severity and death in blunt multiple trauma
    • Siegel JH, Rivkind AI, Dalal S, et al. Early physiologic predictors of injury severity and death in blunt multiple trauma. Arch Surg 1990; 125:498-508. (Pubitemid 20119151)
    • (1990) Archives of Surgery , vol.125 , Issue.4 , pp. 498-508
    • Siegel, J.H.1    Rivkind, A.I.2    Dalal, S.3    Goodarzi, S.4
  • 18
    • 0024542042 scopus 로고
    • The sensitivity of vital signs in identifying major thoracoabdominal hemorrhage
    • DOI 10.1016/0002-9610(89)90649-1
    • Luna GK, Eddy AC, Copass M. The sensitivity of vital signs in identifying major thoracoabdominal hemorrhage. Am J Surg 1989; 157:512-5. (Pubitemid 19127472)
    • (1989) American Journal of Surgery , vol.157 , Issue.5 , pp. 512-515
    • Luna, G.K.1    Eddy, A.C.2    Copass, M.3
  • 19
    • 33846223813 scopus 로고    scopus 로고
    • Post-traumatic hypotension: Should systolic blood pressure of 90-109 mmHg be included?
    • DOI 10.1097/01.shk.0000239772.18151.18, PII 0002438220070200000004
    • Edelman DA, White MT, Tyburski JG, et al. Post-traumatic hypotension: should systolic blood pressure of 90-109 mm Hg be included? Shock 2007;27:134-8. (Pubitemid 46105828)
    • (2007) Shock , vol.27 , Issue.2 , pp. 134-138
    • Edelman, D.A.1    White, M.T.2    Tyburski, J.G.3    Wilson, R.F.4
  • 21
    • 0027415523 scopus 로고
    • Unreliability of blood pressure and heart rate to evaluate cardiac output in emergency resuscitation and critical illness
    • Wo CC, Shoemaker WC, Appel PL, et al. Unreliability of blood pressure and heart rate to evaluate cardiac output in emergency resuscitation and critical illness. Crit Care Med 1993;21:218-23. (Pubitemid 23062835)
    • (1993) Critical Care Medicine , vol.21 , Issue.2 , pp. 218-223
    • Wo, C.C.J.1    Shoemaker, W.C.2    Appel, P.L.3    Bishop, M.H.4    Kram, H.B.5    Hardin, E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.