메뉴 건너뛰기




Volumn 311, Issue , 2009, Pages 139-149

Using physical models for anomaly detection in control systems

Author keywords

Anomaly detection; Hydroelectric power plant; SCADA systems

Indexed keywords

CRITICAL INFRASTRUCTURES; FEEDBACK; HYDROELECTRIC POWER; HYDROELECTRIC POWER PLANTS; PUBLIC WORKS;

EID: 84856339254     PISSN: 18684238     EISSN: None     Source Type: Book Series    
DOI: 10.1007/978-3-642-04798-5_10     Document Type: Conference Paper
Times cited : (18)

References (22)
  • 4
    • 36248966550 scopus 로고    scopus 로고
    • Security analysis of multilayer SCADA protocols
    • E. Goetz and S. Shenoi (Eds.), Springer, Boston, Massachusetts
    • J. Edmonds, M. Papa and S. Shenoi, Security analysis of multilayer SCADA protocols, in Critical Infrastructure Protection, E. Goetz and S. Shenoi (Eds.), Springer, Boston, Massachusetts, pp. 205-221, 2007.
    • (2007) Critical Infrastructure Protection , pp. 205-221
    • Edmonds, J.1    Papa, M.2    Shenoi, S.3
  • 5
    • 20444400221 scopus 로고    scopus 로고
    • The design of robust multi-loop cascaded hydro governors
    • I. Eker, The design of robust multi-loop cascaded hydro governors, Engineering with Computers, vol. 20(1), pp. 45-53, 2004.
    • (2004) Engineering With Computers , vol.20 , Issue.1 , pp. 45-53
    • Eker, I.1
  • 6
    • 0035505625 scopus 로고    scopus 로고
    • Analysis of massive measurement loss in large-scale power system state estimation
    • C. Gonzalez-Perez and B. Wollenberg, Analysis of massive measurement loss in large-scale power system state estimation, IEEE Transactions on Power Systems, vol. 16(4), pp. 825-832, 2001.
    • (2001) IEEE Transactions On Power Systems , vol.16 , Issue.4 , pp. 825-832
    • Gonzalez-Perez, C.1    Wollenberg, B.2
  • 13
    • 1642307675 scopus 로고    scopus 로고
    • National Security Telecommunications Advisory Committee, Technical Report, Washington, DC
    • National Security Telecommunications Advisory Committee, Electric Power Risk Assessment, Technical Report, Washington, DC, 1997.
    • (1997) Electric Power Risk Assessment
  • 16
    • 36249007497 scopus 로고    scopus 로고
    • Intrusion detection and event monitoring in SCADA networks
    • E. Goetz and S. Shenoi (Eds.), Springer, Boston, Massachusetts
    • P. Oman and M. Phillips, Intrusion detection and event monitoring in SCADA networks, in Critical Infrastructure Protection, E. Goetz and S. Shenoi (Eds.), Springer, Boston, Massachusetts, pp. 161-173, 2007.
    • (2007) Critical Infrastructure Protection , pp. 161-173
    • Oman, P.1    Phillips, M.2
  • 19
    • 55549120913 scopus 로고    scopus 로고
    • Modeling and detecting anomalies in SCADA systems
    • M. Papa and S. Shenoi (Eds.), Springer, Boston, Massachusetts
    • N. Svendsen and S. Wolthusen, Modeling and detecting anomalies in SCADA systems, in Critical Infrastructure II, M. Papa and S. Shenoi (Eds.), Springer, Boston, Massachusetts, pp. 101-113, 2008.
    • (2008) Critical Infrastructure II , pp. 101-113
    • Svendsen, N.1    Wolthusen, S.2
  • 20
    • 0029674220 scopus 로고    scopus 로고
    • Fluid-structure interaction in liquid-filled pipe systems
    • A. Tijsseling, Fluid-structure interaction in liquid-filled pipe systems, Journal of Fluids and Structures, vol. 10(2), pp. 109-146, 1996.
    • (1996) Journal of Fluids and Structures , vol.10 , Issue.2 , pp. 109-146
    • Tijsseling, A.1
  • 21
    • 34248219140 scopus 로고    scopus 로고
    • Water hammer with fluid-structure interaction in thick-walled pipes
    • A. Tijsseling, Water hammer with fluid-structure interaction in thick-walled pipes, Computers and Structures, vol. 85 (11-14), pp. 844-851, 2007.
    • (2007) Computers and Structures , vol.85 , Issue.11-14 , pp. 844-851
    • Tijsseling, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.