메뉴 건너뛰기




Volumn 26, Issue 1, 2012, Pages 1-11

New Developments in the Prevention of Intravascular Catheter Associated Infections

Author keywords

Bloodstream infection; Catheter related bloodstream infection; Central venous catheter; Intravascular catheter

Indexed keywords

CHLORHEXIDINE; MINOCYCLINE; RIFAMPICIN; SULFADIAZINE SILVER;

EID: 84856271020     PISSN: 08915520     EISSN: 15579824     Source Type: Journal    
DOI: 10.1016/j.idc.2011.09.002     Document Type: Review
Times cited : (23)

References (44)
  • 1
    • 79551713369 scopus 로고    scopus 로고
    • Central line-associated bloodstream infections: prevention and management
    • Weber D.J., Rutala W.A. Central line-associated bloodstream infections: prevention and management. Infect Dis Clin North Am 2011, 25(1):77-102.
    • (2011) Infect Dis Clin North Am , vol.25 , Issue.1 , pp. 77-102
    • Weber, D.J.1    Rutala, W.A.2
  • 2
    • 71449094486 scopus 로고    scopus 로고
    • National Healthcare Safety Network (NHSN) report: data for 2006 through 2008, issued December 2009
    • Edwards J.R., Peterson K.D., Banerjee S., et al. National Healthcare Safety Network (NHSN) report: data for 2006 through 2008, issued December 2009. Am J Infect Control 2009, 37:783-805.
    • (2009) Am J Infect Control , vol.37 , pp. 783-805
    • Edwards, J.R.1    Peterson, K.D.2    Banerjee, S.3
  • 3
    • 79957642420 scopus 로고    scopus 로고
    • Guidelines for the prevention of intravascular catheter-related infections
    • O'Grady N.P., Alexander M., Burns L.A., et al. Guidelines for the prevention of intravascular catheter-related infections. Clin Infect Dis 2011, 52(9):e162-e193.
    • (2011) Clin Infect Dis , vol.52 , Issue.9
    • O'Grady, N.P.1    Alexander, M.2    Burns, L.A.3
  • 4
    • 79952643764 scopus 로고    scopus 로고
    • Centers for Disease Control and Prevention (CDC) Vital signs: central line-associated blood stream infections-United States, 2001, 2008, and 2009
    • Centers for Disease Control and Prevention (CDC) Vital signs: central line-associated blood stream infections-United States, 2001, 2008, and 2009. MMWR Morb Mortal Wkly Rep 2011, 60(8):243-248.
    • (2011) MMWR Morb Mortal Wkly Rep , vol.60 , Issue.8 , pp. 243-248
  • 5
    • 84856264128 scopus 로고    scopus 로고
    • Infections of intravascular catheters and vascular devices
    • Wiley-Blackwell, Chichester, West Sussex, K.B. Crossley, K.K. Jefferson, G. Archer (Eds.)
    • Yanagi H., Sherertz R.J. Infections of intravascular catheters and vascular devices. Staphylococci in human disease 2009, 363-377. Wiley-Blackwell, Chichester, West Sussex. 2nd edition. K.B. Crossley, K.K. Jefferson, G. Archer (Eds.).
    • (2009) Staphylococci in human disease , pp. 363-377
    • Yanagi, H.1    Sherertz, R.J.2
  • 6
    • 84856264132 scopus 로고    scopus 로고
    • Microbial adherence
    • Churchill Livingstone Elsevier, Philadelphia, G.L. Mandell, J.E. Bennett, R.G. Douglas (Eds.)
    • Petri W.A., Mann B.J., Huston C.D. Microbial adherence. Principles and practice of infectious diseases' 2009, 15-25. Churchill Livingstone Elsevier, Philadelphia. 7th edition. G.L. Mandell, J.E. Bennett, R.G. Douglas (Eds.).
    • (2009) Principles and practice of infectious diseases' , pp. 15-25
    • Petri, W.A.1    Mann, B.J.2    Huston, C.D.3
  • 7
    • 0036228505 scopus 로고    scopus 로고
    • Biofilms: survival mechanisms of clinically relevant microorganisms
    • Donlan R.M., Costerton J.W. Biofilms: survival mechanisms of clinically relevant microorganisms. Clin Microbiol Rev 2002, 15:167-193.
    • (2002) Clin Microbiol Rev , vol.15 , pp. 167-193
    • Donlan, R.M.1    Costerton, J.W.2
  • 8
    • 77953236848 scopus 로고    scopus 로고
    • Current concepts in biofilm formation of Staphylococcus epidermidis
    • Fey P.D., Olson M.E. Current concepts in biofilm formation of Staphylococcus epidermidis. Future Microbiol 2010, 5:917-933.
    • (2010) Future Microbiol , vol.5 , pp. 917-933
    • Fey, P.D.1    Olson, M.E.2
  • 9
    • 33750594895 scopus 로고    scopus 로고
    • Persiters: specialized cells responsible for biofilm tolerance
    • Taylor & Francis, Boca Raton (FL), J.L. Pace, M.E. Rupp, R.G. Finch (Eds.)
    • Lewis K., Spoering A.L., Kaldalu N., et al. Persiters: specialized cells responsible for biofilm tolerance. Biofilms, infection, and antimicrobial therapy 2006, 241-256. Taylor & Francis, Boca Raton (FL). J.L. Pace, M.E. Rupp, R.G. Finch (Eds.).
    • (2006) Biofilms, infection, and antimicrobial therapy , pp. 241-256
    • Lewis, K.1    Spoering, A.L.2    Kaldalu, N.3
  • 10
    • 66949140382 scopus 로고    scopus 로고
    • Clinical practice guidelines for the diagnosis and management of intravascular catheter-related infection: 2009 update by the infectious diseases society of America
    • Mermel L.A., Allon M., Bouza E., et al. Clinical practice guidelines for the diagnosis and management of intravascular catheter-related infection: 2009 update by the infectious diseases society of America. Clin Infect Dis 2009, 49:1-45.
    • (2009) Clin Infect Dis , vol.49 , pp. 1-45
    • Mermel, L.A.1    Allon, M.2    Bouza, E.3
  • 11
    • 0036916816 scopus 로고    scopus 로고
    • Guidelines for the prevention of intravascular catheter-related infections
    • O'Grady N.P., Alexander M., Dellinger E.P., et al. Guidelines for the prevention of intravascular catheter-related infections. Infect Control Hosp Epidemiol 2002, 23(12):759-769.
    • (2002) Infect Control Hosp Epidemiol , vol.23 , Issue.12 , pp. 759-769
    • O'Grady, N.P.1    Alexander, M.2    Dellinger, E.P.3
  • 12
    • 26944472473 scopus 로고    scopus 로고
    • Centers for Disease Control and Prevention (CDC) Reduction in central line-associated bloodstream infections among patients in intensive care units-Pennsylvania, April 2001-March 2005
    • Centers for Disease Control and Prevention (CDC) Reduction in central line-associated bloodstream infections among patients in intensive care units-Pennsylvania, April 2001-March 2005. MMWR Morb Mortal Wkly Rep 2005, 54(40):1013-1016.
    • (2005) MMWR Morb Mortal Wkly Rep , vol.54 , Issue.40 , pp. 1013-1016
  • 13
    • 33845880922 scopus 로고    scopus 로고
    • An intervention to decrease catheter-related bloodstream infections in the ICU
    • Pronovost P., Needham D., Berenholtz S., et al. An intervention to decrease catheter-related bloodstream infections in the ICU. NEngl J Med 2006, 355(26):2725-2732.
    • (2006) NEngl J Med , vol.355 , Issue.26 , pp. 2725-2732
    • Pronovost, P.1    Needham, D.2    Berenholtz, S.3
  • 14
    • 77649206944 scopus 로고    scopus 로고
    • Sustaining reductions in catheter related bloodstream infections in Michigan intensive care units: observational study
    • Pronovost P.J., Goeschel C.A., Colantuoni E., et al. Sustaining reductions in catheter related bloodstream infections in Michigan intensive care units: observational study. BMJ 2010, 340:c309.
    • (2010) BMJ , vol.340
    • Pronovost, P.J.1    Goeschel, C.A.2    Colantuoni, E.3
  • 15
    • 79551635296 scopus 로고    scopus 로고
    • Impact of a statewide intensive care unit quality improvement initiative on hospital mortality and length of stay: retrospective comparative analysis
    • Lipitz-Snyderman A., Steinwachs D., Needham D.M., et al. Impact of a statewide intensive care unit quality improvement initiative on hospital mortality and length of stay: retrospective comparative analysis. BMJ 2011, 342:d219.
    • (2011) BMJ , vol.342
    • Lipitz-Snyderman, A.1    Steinwachs, D.2    Needham, D.M.3
  • 16
    • 0030095189 scopus 로고    scopus 로고
    • The role of understaffing in central venous catheter-associated bloodstream infections
    • Fridkin S.K., Pear S.M., Williamson T.H., et al. The role of understaffing in central venous catheter-associated bloodstream infections. Infect Control Hosp Epidemiol 1996, 17(3):150-158.
    • (1996) Infect Control Hosp Epidemiol , vol.17 , Issue.3 , pp. 150-158
    • Fridkin, S.K.1    Pear, S.M.2    Williamson, T.H.3
  • 17
    • 62849123840 scopus 로고    scopus 로고
    • Ultrasound-guided central venous catheter placement decreases complications and decreases placement attempts compared with the landmark technique in patients in a pediatric intensive care unit
    • Froehlich C.D., Rigby M.R., Rosenberg E.S., et al. Ultrasound-guided central venous catheter placement decreases complications and decreases placement attempts compared with the landmark technique in patients in a pediatric intensive care unit. Crit Care Med 2009, 37(3):1090-1096.
    • (2009) Crit Care Med , vol.37 , Issue.3 , pp. 1090-1096
    • Froehlich, C.D.1    Rigby, M.R.2    Rosenberg, E.S.3
  • 18
    • 0043234290 scopus 로고    scopus 로고
    • Ultrasonic locating devices for central venous cannulation: meta-analysis
    • Hind D., Calvert N., McWilliams R., et al. Ultrasonic locating devices for central venous cannulation: meta-analysis. BMJ 2003, 327(7411):361.
    • (2003) BMJ , vol.327 , Issue.7411 , pp. 361
    • Hind, D.1    Calvert, N.2    McWilliams, R.3
  • 19
    • 0029906824 scopus 로고    scopus 로고
    • Ultrasound guidance for placement of central venous catheters: a meta-analysis of the literature
    • Randolph A.G., Cook D.J., Gonzales C.A., et al. Ultrasound guidance for placement of central venous catheters: a meta-analysis of the literature. Crit Care Med 1996, 24(12):2053-2058.
    • (1996) Crit Care Med , vol.24 , Issue.12 , pp. 2053-2058
    • Randolph, A.G.1    Cook, D.J.2    Gonzales, C.A.3
  • 20
    • 79959662270 scopus 로고    scopus 로고
    • Real-time ultrasound-guided subclavian vein cannulation versus the landmark method in critical care patients: a prospective randomized study
    • Fragou M., Gravvanis A., Dimitriou V., et al. Real-time ultrasound-guided subclavian vein cannulation versus the landmark method in critical care patients: a prospective randomized study. Crit Care Med 2011, 39(7):1607-1612.
    • (2011) Crit Care Med , vol.39 , Issue.7 , pp. 1607-1612
    • Fragou, M.1    Gravvanis, A.2    Dimitriou, V.3
  • 21
    • 0037018953 scopus 로고    scopus 로고
    • Chlorhexidine compared with povidone-iodine solution for vascular catheter-site care: a meta-analysis
    • Chaiyakunapruk N., Veenstra D.L., Lipsky B.A., et al. Chlorhexidine compared with povidone-iodine solution for vascular catheter-site care: a meta-analysis. Ann Intern Med 2002, 136(11):792-801.
    • (2002) Ann Intern Med , vol.136 , Issue.11 , pp. 792-801
    • Chaiyakunapruk, N.1    Veenstra, D.L.2    Lipsky, B.A.3
  • 22
    • 78449258029 scopus 로고    scopus 로고
    • The past, present, and future of healthcare-associated infection prevention in pediatrics: catheter-associated bloodstream infections
    • Bryant K.A., Zerr D.M., Huskins W.C., et al. The past, present, and future of healthcare-associated infection prevention in pediatrics: catheter-associated bloodstream infections. Infect Control Hosp Epidemiol 2010, 31(Suppl 1):S27-S31.
    • (2010) Infect Control Hosp Epidemiol , vol.31 , Issue.SUPPL. 1
    • Bryant, K.A.1    Zerr, D.M.2    Huskins, W.C.3
  • 23
    • 59049090422 scopus 로고    scopus 로고
    • Prevention of central venous catheter related infections with chlorhexidine gluconate impregnated wound dressings: a randomized controlled trial
    • Ruschulte H., Franke M., Gastmeier P., et al. Prevention of central venous catheter related infections with chlorhexidine gluconate impregnated wound dressings: a randomized controlled trial. Ann Hematol 2009, 88(3):267-272.
    • (2009) Ann Hematol , vol.88 , Issue.3 , pp. 267-272
    • Ruschulte, H.1    Franke, M.2    Gastmeier, P.3
  • 24
    • 63349094816 scopus 로고    scopus 로고
    • Chlorhexidine-impregnated sponges and less frequent dressing changes for prevention of catheter-related infections in critically ill adults: a randomized controlled trial
    • Timsit J.F., Schwebel C., Bouadma L., et al. Chlorhexidine-impregnated sponges and less frequent dressing changes for prevention of catheter-related infections in critically ill adults: a randomized controlled trial. JAMA 2009, 301(12):1231-1241.
    • (2009) JAMA , vol.301 , Issue.12 , pp. 1231-1241
    • Timsit, J.F.1    Schwebel, C.2    Bouadma, L.3
  • 25
    • 0033585457 scopus 로고    scopus 로고
    • Efficacy of antiseptic-impregnated central venous catheters in preventing catheter-related bloodstream infection: a meta-analysis
    • Veenstra D.L., Saint S., Saha S., et al. Efficacy of antiseptic-impregnated central venous catheters in preventing catheter-related bloodstream infection: a meta-analysis. JAMA 1999, 281:261-267.
    • (1999) JAMA , vol.281 , pp. 261-267
    • Veenstra, D.L.1    Saint, S.2    Saha, S.3
  • 26
    • 0033531147 scopus 로고    scopus 로고
    • Acomparison of two antimicrobial-impregnated central venous catheters. Catheter Study Group
    • Darouiche R.O., Raad I.I., Heard S.O., et al. Acomparison of two antimicrobial-impregnated central venous catheters. Catheter Study Group. NEngl J Med 1999, 340:1-8.
    • (1999) NEngl J Med , vol.340 , pp. 1-8
    • Darouiche, R.O.1    Raad, I.I.2    Heard, S.O.3
  • 27
    • 0030753776 scopus 로고    scopus 로고
    • Central venous catheters coated with minocycline and rifampin for the prevention of catheter-related colonization and bloodstream infections. A randomized, double-blind trial. The Texas Medical Center Catheter Study Group
    • Raad I., Darouiche R., Dupuis J., et al. Central venous catheters coated with minocycline and rifampin for the prevention of catheter-related colonization and bloodstream infections. A randomized, double-blind trial. The Texas Medical Center Catheter Study Group. Ann Intern Med 1997, 127:267-274.
    • (1997) Ann Intern Med , vol.127 , pp. 267-274
    • Raad, I.1    Darouiche, R.2    Dupuis, J.3
  • 28
    • 79251549398 scopus 로고    scopus 로고
    • Clinical effectiveness and risk of emerging resistance associated with prolonged use of antibiotic-impregnated catheters: more than 0.5 million catheter days and 7 years of clinical experience
    • Ramos E.R., Reitzel R., Jiang Y., et al. Clinical effectiveness and risk of emerging resistance associated with prolonged use of antibiotic-impregnated catheters: more than 0.5 million catheter days and 7 years of clinical experience. Crit Care Med 2011, 39(2):245-251.
    • (2011) Crit Care Med , vol.39 , Issue.2 , pp. 245-251
    • Ramos, E.R.1    Reitzel, R.2    Jiang, Y.3
  • 29
    • 79251507686 scopus 로고    scopus 로고
    • Ethanol-lock therapy for the prevention of central venous access device infections in pediatric patients with intestinal failure
    • Cober M.P. Ethanol-lock therapy for the prevention of central venous access device infections in pediatric patients with intestinal failure. JPEN J Parenter Enteral Nutr 2011, 35(1):67.
    • (2011) JPEN J Parenter Enteral Nutr , vol.35 , Issue.1 , pp. 67
    • Cober, M.P.1
  • 30
    • 79251474918 scopus 로고    scopus 로고
    • Prevention of dialysis catheter malfunction with recombinant tissue plasminogen activator
    • Hemmelgarn B.R. Prevention of dialysis catheter malfunction with recombinant tissue plasminogen activator. NEngl J Med 2011, 364(4):303.
    • (2011) NEngl J Med , vol.364 , Issue.4 , pp. 303
    • Hemmelgarn, B.R.1
  • 31
    • 52949108510 scopus 로고    scopus 로고
    • Aprospective double-blind randomized trial comparing intraluminal ethanol with heparinized saline for the prevention of catheter-associated bloodstream infection in immunosuppressed haematology patients
    • Sanders J. Aprospective double-blind randomized trial comparing intraluminal ethanol with heparinized saline for the prevention of catheter-associated bloodstream infection in immunosuppressed haematology patients. JAntimicrob Chemother 2008, 62(4):809.
    • (2008) JAntimicrob Chemother , vol.62 , Issue.4 , pp. 809
    • Sanders, J.1
  • 32
    • 79953204575 scopus 로고    scopus 로고
    • Anovel antimicrobial and antithrombotic lock solution for hemodialysis catheters: a multi-center, controlled, randomized trial
    • Maki D.G., Ash S.R., Winger R.K., et al. Anovel antimicrobial and antithrombotic lock solution for hemodialysis catheters: a multi-center, controlled, randomized trial. Crit Care Med 2011, 39(4):613.
    • (2011) Crit Care Med , vol.39 , Issue.4 , pp. 613
    • Maki, D.G.1    Ash, S.R.2    Winger, R.K.3
  • 33
    • 35648938269 scopus 로고    scopus 로고
    • Effectiveness of chlorhexidine bathing to reduce catheter-associated bloodstream infections in medical intensive care unit patients
    • Bleasdale S.C. Effectiveness of chlorhexidine bathing to reduce catheter-associated bloodstream infections in medical intensive care unit patients. Arch Intern Med 2007, 167(19):2073.
    • (2007) Arch Intern Med , vol.167 , Issue.19 , pp. 2073
    • Bleasdale, S.C.1
  • 34
    • 70350004872 scopus 로고    scopus 로고
    • Effectiveness of routine patient cleansing with chlorhexidine gluconate for infection prevention in the medical intensive care unit
    • Popovich K.J. Effectiveness of routine patient cleansing with chlorhexidine gluconate for infection prevention in the medical intensive care unit. Infect Control Hosp Epidemiol 2009, 30(10):959.
    • (2009) Infect Control Hosp Epidemiol , vol.30 , Issue.10 , pp. 959
    • Popovich, K.J.1
  • 35
    • 71949099817 scopus 로고    scopus 로고
    • Prevention of bloodstream infections by use of daily chlorhexidine baths for patients at a long-term acute care hospital
    • Munoz-Price L.S. Prevention of bloodstream infections by use of daily chlorhexidine baths for patients at a long-term acute care hospital. Infect Control Hosp Epidemiol 2009, 30(11):1031.
    • (2009) Infect Control Hosp Epidemiol , vol.30 , Issue.11 , pp. 1031
    • Munoz-Price, L.S.1
  • 36
    • 79952394549 scopus 로고    scopus 로고
    • Impact of chlorhexidine bathing on hospital-acquired infections among general medical patients
    • Kassakian S.Z., Mermel L.A., Jefferson J.A., et al. Impact of chlorhexidine bathing on hospital-acquired infections among general medical patients. Infect Control Hosp Epidemiol 2011, 32(3):238-243.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , Issue.3 , pp. 238-243
    • Kassakian, S.Z.1    Mermel, L.A.2    Jefferson, J.A.3
  • 37
    • 34250786073 scopus 로고    scopus 로고
    • Increased rate of catheter-related bloodstream infection associated with use of a needleless mechanical valve device at a long-term acute care hospital
    • Salgado C.D., Chinnes L., Paczesny T.H., et al. Increased rate of catheter-related bloodstream infection associated with use of a needleless mechanical valve device at a long-term acute care hospital. Infect Control Hosp Epidemiol 2007, 28(6):684-688.
    • (2007) Infect Control Hosp Epidemiol , vol.28 , Issue.6 , pp. 684-688
    • Salgado, C.D.1    Chinnes, L.2    Paczesny, T.H.3
  • 38
    • 72049126603 scopus 로고    scopus 로고
    • Health care-associated bloodstream infections associated with negative- or positive-pressure or displacement mechanical valve needleless connectors
    • Jarvis W.R., Murphy C., Hall K.K., et al. Health care-associated bloodstream infections associated with negative- or positive-pressure or displacement mechanical valve needleless connectors. Clin Infect Dis 2009, 49(12):1821-1827.
    • (2009) Clin Infect Dis , vol.49 , Issue.12 , pp. 1821-1827
    • Jarvis, W.R.1    Murphy, C.2    Hall, K.K.3
  • 39
    • 34249080865 scopus 로고    scopus 로고
    • Outbreak of bloodstream infection temporally associated with the use of an intravascular needleless valve
    • Rupp M.E., Sholtz L.A., Jourdan D.R., et al. Outbreak of bloodstream infection temporally associated with the use of an intravascular needleless valve. Clin Infect Dis 2007, 44(11):1408-1414.
    • (2007) Clin Infect Dis , vol.44 , Issue.11 , pp. 1408-1414
    • Rupp, M.E.1    Sholtz, L.A.2    Jourdan, D.R.3
  • 40
    • 77953004088 scopus 로고    scopus 로고
    • Invitro studies of a novel antimicrobial luer-activated needleless connector for prevention of catheter-related bloodstream infection
    • Maki D.G. Invitro studies of a novel antimicrobial luer-activated needleless connector for prevention of catheter-related bloodstream infection. Clin Infect Dis 2010, 50(12):1580.
    • (2010) Clin Infect Dis , vol.50 , Issue.12 , pp. 1580
    • Maki, D.G.1
  • 41
    • 0036147906 scopus 로고    scopus 로고
    • Sutureless securement device reduces complications of peripherally inserted central venous catheters
    • Yamamoto A.J., Solomon J.A., Soulen M.C., et al. Sutureless securement device reduces complications of peripherally inserted central venous catheters. JVasc Interv Radiol 2002, 13(1):77-81.
    • (2002) JVasc Interv Radiol , vol.13 , Issue.1 , pp. 77-81
    • Yamamoto, A.J.1    Solomon, J.A.2    Soulen, M.C.3
  • 42
    • 84856270269 scopus 로고    scopus 로고
    • Centers for Medicare and Medicaid Services. Hospital-acquired conditions. Available at: Accessed April 25
    • Centers for Medicare and Medicaid Services. Hospital-acquired conditions. Available at: Accessed April 25, 2011. http://www.cms.gov/HospitalAcqCond/06_Hospital-Acquired_Conditions.asp.
    • (2011)
  • 43
    • 18844455262 scopus 로고    scopus 로고
    • Guidance on public reporting of healthcare-associated infections: recommendations of the Healthcare Infection Control Practices Advisory Committee
    • McKibben L., Horan T., Tokars J.I., et al. Guidance on public reporting of healthcare-associated infections: recommendations of the Healthcare Infection Control Practices Advisory Committee. Am J Infect Control 2005, 33(4):217-226.
    • (2005) Am J Infect Control , vol.33 , Issue.4 , pp. 217-226
    • McKibben, L.1    Horan, T.2    Tokars, J.I.3
  • 44
    • 23744489549 scopus 로고    scopus 로고
    • Risk of catheter-related bloodstream infection with peripherally inserted central venous catheters used in hospitalized patients
    • Safdar N., Maki D.G. Risk of catheter-related bloodstream infection with peripherally inserted central venous catheters used in hospitalized patients. Chest 2005, 128(2):489-495.
    • (2005) Chest , vol.128 , Issue.2 , pp. 489-495
    • Safdar, N.1    Maki, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.