메뉴 건너뛰기




Volumn 27, Issue 1, 2012, Pages 353-362

Rotor angle stability with high penetrations of wind generation

Author keywords

Reactive power; synchronous generators; transient analysis; wind power generation

Indexed keywords

ACTIVE POWER; ACTIVE POWER FLOW; ANGULAR SEPARATION; CONTINGENCY EVENTS; CONTROL VOLTAGES; DYNAMIC PHENOMENA; ROTOR ANGLE STABILITY; VARIABLE SPEED WIND TURBINES; WIND GENERATION;

EID: 84856263235     PISSN: 08858950     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRS.2011.2161097     Document Type: Article
Times cited : (232)

References (23)
  • 1
    • 33947418456 scopus 로고    scopus 로고
    • Direct active and reactive power control of DFIG for wind energy generation
    • Sep.
    • L. Xu and P. Cartwright, "Direct active and reactive power control of DFIG for wind energy generation," IEEE Trans. Energy Convers., vol. 21, no. 3, pp. 750.758, Sep. 2006.
    • (2006) IEEE Trans. Energy Convers. , vol.21 , Issue.3 , pp. 750758
    • Xu, L.1    Cartwright, P.2
  • 2
    • 29244448716 scopus 로고    scopus 로고
    • Modeling and experimental verification of grid interaction of a DFIG wind turbine
    • Dec.
    • A. Petersson, T. Thiringer, L. Harnefors, and T. Petr.u, "Modeling and experimental verification of grid interaction of a DFIG wind turbine," IEEE Trans. Energy Convers., vol. 20, no. 4, pp. 878.886, Dec. 2005.
    • (2005) IEEE Trans. Energy Convers. , vol.20 , Issue.4 , pp. 878886
    • Petersson, A.1    Thiringer, T.2    Harnefors, L.3    Petru, T.4
  • 3
    • 34249792921 scopus 로고    scopus 로고
    • Reactive power control strategies for DFIG-based plants
    • Jun.
    • M. Kayikçi and J. V. Milanović, "Reactive power control strategies for DFIG-based plants," IEEE Trans. Energy Convers., vol. 22, no. 2, pp. 389.396, Jun. 2007.
    • (2007) IEEE Trans. Energy Convers. , vol.22 , Issue.2 , pp. 389396
    • Kayikçi, M.1    Milanović, J.V.2
  • 4
    • 34247185867 scopus 로고    scopus 로고
    • Frequency support from doubly fed induction generator wind turbines
    • Mar.
    • G. Ramtharan, J. B. Ekanayake, and N. Jenkins, "Frequency support from doubly fed induction generator wind turbines," IET Renew. Power Gen., vol. 1, no. 1, pp. 3.9, Mar. 2007.
    • (2007) IET Renew. Power Gen. , vol.1 , Issue.1 , pp. 39
    • Ramtharan, G.1    Ekanayake, J.B.2    Jenkins, N.3
  • 5
    • 32144457162 scopus 로고    scopus 로고
    • Wind turbines emulating inertia and supporting primary frequency control
    • Feb.
    • J. Morren, S. W. H. de Haan, W. L. Kling, and J. A. Ferreria, "Wind turbines emulating inertia and supporting primary frequency control," IEEE Trans. Power Syst., vol. 21, no. 1, pp. 433.434, Feb. 2006.
    • (2006) IEEE Trans. Power Syst. , vol.21 , Issue.1 , pp. 433434
    • Morren, J.1    De Haan, S.W.H.2    Kling, W.L.3    Ferreria, J.A.4
  • 6
    • 76649114328 scopus 로고    scopus 로고
    • A steady-state voltage stability analysis of power systems with high penetrations of wind
    • Feb.
    • E. Vittal, M. O'Malley, and A. Keane, "A steady-state voltage stability analysis of power systems with high penetrations of wind," IEEE Trans. Power Syst., vol. 25, no. 1, pp. 433-442, Feb. 2010.
    • (2010) IEEE Trans. Power Syst. , vol.25 , Issue.1 , pp. 433-442
    • Vittal, E.1    O'Malley, M.2    Keane, A.3
  • 7
    • 36348950411 scopus 로고    scopus 로고
    • Voltage and transient stability support by wind farms complying with the E. ON netz grid code
    • Nov.
    • N. R. Ullah, T. Thiringer, and D. Karlsson, "Voltage and transient stability support by wind farms complying with the E. ON netz grid code," IEEE Trans. Power Syst., vol. 22, no. 4, pp. 1647-1656, Nov. 2007.
    • (2007) IEEE Trans. Power Syst. , vol.22 , Issue.4 , pp. 1647-1656
    • Ullah, N.R.1    Thiringer, T.2    Karlsson, D.3
  • 10
    • 34548047031 scopus 로고    scopus 로고
    • A large wind power system in almost island operation-A Danish case study
    • Aug.
    • V. Akhmatov and P. B. Eriksen, "A large wind power system in almost island operation-A Danish case study," IEEE Trans. Power Syst., vol. 22, no. 3, pp. 937-943, Aug. 2007.
    • (2007) IEEE Trans. Power Syst. , vol.22 , Issue.3 , pp. 937-943
    • Akhmatov, V.1    Eriksen, P.B.2
  • 11
    • 68349150311 scopus 로고    scopus 로고
    • Impact of increased penetrations of DFIG based wind turbine generators on transient and small signal stability
    • Aug.
    • D. Gautam, V. Vittal, and T. Harbour, "Impact of increased penetrations of DFIG based wind turbine generators on transient and small signal stability," IEEE Trans. Power Syst., vol. 24, no. 3, pp. 1426-1434, Aug. 2009.
    • (2009) IEEE Trans. Power Syst. , vol.24 , Issue.3 , pp. 1426-1434
    • Gautam, D.1    Vittal, V.2    Harbour, T.3
  • 12
    • 28244449042 scopus 로고    scopus 로고
    • Frequency control and wind turbine technologies
    • Nov.
    • G. Lalor, A. Mullane, and M. O'Malley, "Frequency control and wind turbine technologies," IEEE Trans. Power Syst., vol. 20, no. 4, pp. 1905-1913, Nov. 2005.
    • (2005) IEEE Trans. Power Syst. , vol.20 , Issue.4 , pp. 1905-1913
    • Lalor, G.1    Mullane, A.2    O'Malley, M.3
  • 14
    • 34249798182 scopus 로고    scopus 로고
    • Proportional-integral regulatorbased approach to wind farm reactive power management for secondary voltage control
    • Jun.
    • G. Tapia, A. Tapia, and J. X. Ostolazam, "Proportional-integral regulatorbased approach to wind farm reactive power management for secondary voltage control," IEEE Trans. Energy Convers., vol. 22, no. 2, pp. 488-498, Jun. 2007.
    • (2007) IEEE Trans. Energy Convers. , vol.22 , Issue.2 , pp. 488-498
    • Tapia, G.1    Tapia, A.2    Ostolazam, J.X.3
  • 15
    • 4544388007 scopus 로고    scopus 로고
    • Co-ordinated voltage control strategy for a doubly-fed induction generator (DFIG)-based wind farm
    • Jul.
    • P. Cartwright, L. Holdsworth, J. B. Ekanayake, and N. Jenkins, "Co-ordinated voltage control strategy for a doubly-fed induction generator (DFIG)-based wind farm," Proc. Inst. Elect. Eng., Gen., Transm., Distrib., vol. 151, no. 4, pp. 495-502, Jul. 2004.
    • (2004) Proc. Inst. Elect. Eng., Gen., Transm., Distrib. , vol.151 , Issue.4 , pp. 495-502
    • Cartwright, P.1    Holdsworth, L.2    Ekanayake, J.B.3    Jenkins, N.4
  • 18
    • 0029355022 scopus 로고
    • Standard load models for power flow and dynamic performance simulation
    • IEEE Task Force on Load Representation for Dynamic Performance, Aug.
    • IEEE Task Force on Load Representation for Dynamic Performance, "Standard load models for power flow and dynamic performance simulation," IEEE Trans. Power Syst., vol. 10, no. 3, pp. 1302-1313, Aug. 1995.
    • (1995) IEEE Trans. Power Syst. , vol.10 , Issue.3 , pp. 1302-1313
  • 20
    • 84856243070 scopus 로고    scopus 로고
    • Surrey, BC, Canada, DSATools User Manual
    • Powertech Labs Inc. Surrey, BC, Canada, DSATools User Manual.
    • Powertech Labs Inc