Volumn 33, Issue 1, 2012, Pages 66-81

TGFβ3 immunoassay standardization: Comparison of NIBSC reference preparation code 98/608 with avotermin Lot 205-0505-005

Author keywords

clinical trials; immunoenzymometric assay; Juvista; method comparison; standardization; transforming growth factor beta 3

Indexed keywords

AVOTERMIN; TRANSFORMING GROWTH FACTOR BETA3;

EID: 84856241460     PISSN: 15321819     EISSN: 15324230     Source Type: Journal    
DOI: 10.1080/15321819.2011.600402     Document Type: Article
Times cited : (9)

References (8)
  • 2
    • 78650078703 scopus 로고    scopus 로고
    • Scar improving efficacy of avotermin administered into the wound margins of skin incisions as evaluated by a randomized, double blind, placebo-controlled, phase II, clinical trial
    • Bush, J.; Duncan, J.; Bond, J.; Durani, P.; So, K.; Mason, T.; O'Kane, S.; Ferguson, M. W. J. Scar improving efficacy of avotermin administered into the wound margins of skin incisions as evaluated by a randomized, double blind, placebo-controlled, phase II, clinical trial. Plast. Reconstr. Surg. 2010, 126, 1604-1615.
    • (2010) Plast. Reconstr. Surg. , vol.126 , pp. 1604-1615
    • Bush, J.1    Duncan, J.2    Bond, J.3    Durani, P.4    So, K.5    Mason, T.6    O'Kane, S.7    Ferguson, M.W.J.8
  • 3
    • 0003686264 scopus 로고
    • World Health Organization, Geneva, Switzerland, annex 4
    • WHO Technical Report Series No. 800 [Report]. World Health Organization, Geneva, Switzerland, 1990, annex 4.
    • (1990) WHO Technical Report Series No. 800 [Report]
  • 4
    • 0032708438 scopus 로고    scopus 로고
    • Comparison of pituitary and recombinant human thyroid stimulating hormone (rhTSH) in a multicentre collaborative study: Establishment of the first World Health Organization reference reagent for rhTSH
    • Rafferty, B.; Gaines Das, R. Comparison of pituitary and recombinant human thyroid stimulating hormone (rhTSH) in a multicentre collaborative study: establishment of the first World Health Organization reference reagent for rhTSH. Clin. Chem. 1999, 45, 2207-2215.
    • (1999) Clin. Chem. , vol.45 , pp. 2207-2215
    • Rafferty, B.1    Gaines Das, R.2
  • 5
    • 0021821086 scopus 로고
    • The second international reference preparation of thyroid-stimulating hormone, human, for immunoassay: Calibration by bioassay and immunoassay in an international collaborative study
    • Gaines Das, R. E.; Bristow, A. F. The second international reference preparation of thyroid-stimulating hormone, human, for immunoassay: Calibration by bioassay and immunoassay in an international collaborative study. J. Endocr. 1985, 104, 367-379. (Pubitemid 15078000)
    • (1985) Journal of Endocrinology , vol.104 , Issue.3 , pp. 367-379
    • Gaines Das, R.E.1    Bristow, A.F.2
  • 6
    • 7944228790 scopus 로고    scopus 로고
    • Standardization and calibration of cytokine immunoassays
    • Wadhwa, M.; Mire-Sluis, A.; Thorpe, R. Standardization and calibration of cytokine immunoassays. Revue de l'ACOMEN 1999, 5, 276-284.
    • (1999) Revue de l'Acomen , vol.5 , pp. 276-284
    • Wadhwa, M.1    Mire-Sluis, A.2    Thorpe, R.3
  • 7
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • DOI 10.1191/096228099673819272
    • Bland, J. M.; Altman, D. G. Measuring agreement in method comparison studies. Stat. Methods Med. Res. 1999, 8, 135-160. (Pubitemid 29425900)
    • (1999) Statistical Methods in Medical Research , vol.8 , Issue.2 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 8
    • 0019596036 scopus 로고
    • Evaluation of method-comparison data
    • Eksborg, S. Evaluation of method-comparison data. Clin. Chem. 1991, 27, 1311-1312.
    • (1991) Clin. Chem. , vol.27 , pp. 1311-1312
    • Eksborg, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.