메뉴 건너뛰기




Volumn 161, Issue 1, 2012, Pages 824-831

Ultra-sensitive detection of pathogenic microorganism using surface-engineered impedimetric immunosensor

Author keywords

Biosensors; E. coli O157:H7; Electroanalytical methods; Hyaluronic acid; Surface modification

Indexed keywords

BACTERIAL DETECTION; CAPTURE EFFICIENCY; E. COLI; E.COLI O157:H7; ELECTROANALYTICAL METHOD; ELECTROCHEMICAL IMMUNOSENSORS; ESCHERICHIA COLI O157:H7; GOLD ELECTRODES; HIGH CONCENTRATION; HIGHLY SENSITIVE; HYALURONIC ACIDS; IMPEDIMETRIC IMMUNOSENSORS; LABEL FREE; LIMIT OF DETECTION; NORMALIZED IMPEDANCE; PATHOGENIC BACTERIUM; PATHOGENIC MICROORGANISMS; QUANTITATIVE DETECTION; REDOX PROBE; SPECIFIC DETECTION; SPECIFIC NATURE; STAPHYLOCOCCUS AUREUS;

EID: 84856225863     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2011.11.041     Document Type: Article
Times cited : (35)

References (32)
  • 1
    • 0037106516 scopus 로고    scopus 로고
    • Immunobiosensor chips for detection of Escherichia coli O157:H7 using electrochemical impedance spectroscopy
    • C. Ruan, L. Yang, and Y. Li Immunobiosensor chips for detection of Escherichia coli O157:H7 using electrochemical impedance spectroscopy Analytical Chemistry 74 2002 4814 4820
    • (2002) Analytical Chemistry , vol.74 , pp. 4814-4820
    • Ruan, C.1    Yang, L.2    Li, Y.3
  • 2
    • 0142060222 scopus 로고    scopus 로고
    • Confirmation of viable E. coli O157:H7 by enrichment and PCR after rapid biosensor detection
    • DOI 10.1016/S0167-7012(03)00133-7
    • T.B. Tims, and D.V. Lim Confirmation of viable E. coli O157:H7 by enrichment and PCR after rapid biosensor detection Journal of Microbiological Methods 55 2003 141 147 (Pubitemid 37297653)
    • (2003) Journal of Microbiological Methods , vol.55 , Issue.1 , pp. 141-147
    • Tims, T.B.1    Lim, D.V.2
  • 3
    • 11144231293 scopus 로고    scopus 로고
    • A high density microelectrode array biosensor for detection of E. coli O157:H7
    • DOI 10.1016/j.bios.2004.07.021, PII S0956566304003355
    • S.M. Radke, and E.C. Alocilja A high density microelectrode array biosensor for detection of E. coli O157:H7 Biosensors and Bioelectronics 20 2005 1662 1667 (Pubitemid 40051257)
    • (2005) Biosensors and Bioelectronics , vol.20 , Issue.SPEC. ISS. 8 , pp. 1662-1667
    • Radke, S.M.1    Alocilja, E.C.2
  • 4
    • 33846448162 scopus 로고    scopus 로고
    • Pathogen detection: A perspective of traditional methods and biosensors
    • DOI 10.1016/j.bios.2006.06.036, PII S0956566306003071
    • O. Lazcka, F.J.D. Campo, and F.X. Munoz Pathogen detection: a perspective of traditional methods and biosensors Biosensors and Bioelectronics 22 2007 1205 1217 (Pubitemid 46138081)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.7 , pp. 1205-1217
    • Lazcka, O.1    Campo, F.J.D.2    Munoz, F.X.3
  • 7
    • 0017365816 scopus 로고
    • Characteristics of the microplate method of enzyme linked immunosorbent assay for the detection of plant viruses
    • M.F. Clark, and A.N. Adams Characteristics of the microplate method of enzyme-linked immunosorbent assay for the detection of plant viruses Journal of General Virology 34 1977 475 483 (Pubitemid 8051946)
    • (1977) Journal of General Virology , vol.34 , Issue.3 , pp. 475-483
    • Clark, M.F.1    Adams, A.N.2
  • 9
    • 33846344312 scopus 로고    scopus 로고
    • Self-assembled PEG monolayer based SPR immunosensor for label-free detection of insulin
    • DOI 10.1016/j.bios.2006.06.012, PII S0956566306002909
    • K.V. Gobi, H. Iwasaka, and N. Miura Self-assembled PEG monolayer based SPR immunosensor for label-free detection of insulin Biosensors and Bioelectronics 22 2007 1382 1389 (Pubitemid 46135994)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.7 , pp. 1382-1389
    • Gobi, K.V.1    Iwasaka, H.2    Miura, N.3
  • 12
    • 45849116521 scopus 로고    scopus 로고
    • The use of electrochemical impedance spectroscopy for biosensing
    • F. Lisdat, and D. Schäfer The use of electrochemical impedance spectroscopy for biosensing Analytical and Bioanalytical Chemistry 391 2008 1555 1567
    • (2008) Analytical and Bioanalytical Chemistry , vol.391 , pp. 1555-1567
    • Lisdat, F.1    Schäfer, D.2
  • 13
    • 38349133990 scopus 로고    scopus 로고
    • Electrical/electrochemical impedance for rapid detection of foodborne pathogenic bacteria
    • L. Yang, and R. Bashir Electrical/electrochemical impedance for rapid detection of foodborne pathogenic bacteria Biotechnology Advances 26 2008 135 150
    • (2008) Biotechnology Advances , vol.26 , pp. 135-150
    • Yang, L.1    Bashir, R.2
  • 14
    • 29144535795 scopus 로고    scopus 로고
    • Impedance spectroscopy: A powerful tool for rapid biomolecular screening and cell culture monitoring
    • DOI 10.1002/elan.200503371
    • I.O. K'Owino, and O.A. Sadik Impedance spectroscopy: a powerful tool for rapid biomolecular screening and cell culture monitoring Electroanalysis 17 2005 2101 2113 (Pubitemid 41810053)
    • (2005) Electroanalysis , vol.17 , Issue.23 , pp. 2101-2113
    • K'Owino, I.O.1    Sadik, O.A.2
  • 16
    • 33845661145 scopus 로고    scopus 로고
    • Hyaluronic acid: A natural biopolymer with a broad range of biomedical and industrial applications
    • DOI 10.1007/s10529-006-9219-z
    • G. Kogan, L. Soltes, R. Stern, and P. Gemeiner Hyaluronic acid: a natural biopolymer with a broad range of biomedical and industrial applications Biotechnology Letters 29 2007 17 25 (Pubitemid 44950153)
    • (2007) Biotechnology Letters , vol.29 , Issue.1 , pp. 17-25
    • Kogan, G.1    Soltes, L.2    Stern, R.3    Gemeiner, P.4
  • 17
    • 0037444256 scopus 로고    scopus 로고
    • Atomic force microscopy evaluation of aqueous interfaces of immobilized hyaluronan
    • DOI 10.1016/S0021-9797(02)00204-7
    • M. Morra, C. Cassinelli, A. Pavesio, and D. Renier Atomic force microscopy evaluation of aqueous interfaces of immobilized hyaluronan Journal of Colloid and Interface Science 259 2003 236 243 (Pubitemid 36349311)
    • (2003) Journal of Colloid and Interface Science , vol.259 , Issue.2 , pp. 236-243
    • Morra, M.1    Cassinelli, C.2    Pavesio, A.3    Renier, D.4
  • 18
    • 78651172018 scopus 로고
    • Effects of dihydrostreptomycin treatment on the growth of Escherichia coli after removal of extracellular antibiotic
    • M. Kogut, J.W. Lightbown, and P. Isaacson Effects of dihydrostreptomycin treatment on the growth of Escherichia coli after removal of extracellular antibiotic Microbiology 39 1965 165 183
    • (1965) Microbiology , vol.39 , pp. 165-183
    • Kogut, M.1    Lightbown, J.W.2    Isaacson, P.3
  • 19
    • 37049079283 scopus 로고
    • A novel hydrogel matrix on gold surfaces in surface plasmon resonance sensors for fast and efficient covalent immobilization of ligands
    • S. Lofas, and B. Johnsson A novel hydrogel matrix on gold surfaces in surface plasmon resonance sensors for fast and efficient covalent immobilization of ligands Journal of the Chemical Society, Chemical Communications 1990 1526 1528
    • (1990) Journal of the Chemical Society, Chemical Communications , pp. 1526-1528
    • Lofas, S.1    Johnsson, B.2
  • 20
    • 31944433134 scopus 로고    scopus 로고
    • Determination of environmental organic pollutants with a portable optical immunosensor
    • DOI 10.1016/j.talanta.2005.09.049, PII S0039914005006624
    • E. Mauriz, A. Calle, A. Montoya, and L.M. Lechuga Determination of environmental organic pollutants with a portable optical immunosensor Talanta 69 2006 359 364 (Pubitemid 43190183)
    • (2006) Talanta , vol.69 , Issue.SPEC. ISS. 2 , pp. 359-364
    • Mauriz, E.1    Calle, A.2    Montoya, A.3    Lechuga, L.M.4
  • 21
    • 0038699076 scopus 로고    scopus 로고
    • Covalently coupling the antibody on an amine-self-assembled gold surface to probe hyaluronan-binding protein with capacitance measurement
    • DOI 10.1016/S0956-5663(02)00253-1, PII S0956566302002531
    • D. Jiang, J. Tang, B. Liu, P. Yang, X. Shen, and J. Kong Covalently coupling the antibody on an amine-self-assembled gold surface to probe hyaluronan-binding protein with capacitance measurement Biosensors and Bioelectronics 18 2003 1183 1191 (Pubitemid 36638669)
    • (2003) Biosensors and Bioelectronics , vol.18 , Issue.9 , pp. 1183-1191
    • Jiang, D.1    Tang, J.2    Liu, B.3    Yang, P.4    Shen, X.5    Kong, J.6
  • 22
    • 33947713763 scopus 로고    scopus 로고
    • Interdigitated array microelectrode based impedance biosensor coupled with magnetic nanoparticle-antibody conjugates for detection of Escherichia coli O157:H7 in food samples
    • DOI 10.1016/j.bios.2006.08.030, PII S095656630600409X
    • M. Varshney, and Y. Li Interdigitated array microelectrode based impedance biosensor coupled with magnetic nanoparticle-antibody conjugates for detection of Escherichia coli O157:H7 in food samples Biosensors and Bioelectronics 22 2007 2408 2414 (Pubitemid 46505255)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.11 , pp. 2408-2414
    • Varshney, M.1    Li, Y.2
  • 23
    • 33845184543 scopus 로고
    • Formation of monolayers by the coadsorption of thiols on gold: Variation in the head group, tail group, and solvent
    • C.D. Bain, J. Evall, and G.M. Whitesides Formation of monolayers by the coadsorption of thiols on gold: variation in the head group, tail group, and solvent Journal of the American Chemical Society 111 1989 7155 7164
    • (1989) Journal of the American Chemical Society , vol.111 , pp. 7155-7164
    • Bain, C.D.1    Evall, J.2    Whitesides, G.M.3
  • 25
    • 79960563551 scopus 로고    scopus 로고
    • Influence of attached bacteria and biofilm on double-layer capacitance during biofilm monitoring by electrochemical impedance spectroscopy
    • T. Kim, J. Kang, J.H. Lee, and J. Yoon Influence of attached bacteria and biofilm on double-layer capacitance during biofilm monitoring by electrochemical impedance spectroscopy Water Research 45 2011 4615 4622
    • (2011) Water Research , vol.45 , pp. 4615-4622
    • Kim, T.1    Kang, J.2    Lee, J.H.3    Yoon, J.4
  • 26
    • 0029029571 scopus 로고
    • Self-assembled monolayers and enzyme electrodes: Progress, problems and prospects
    • S.E. Creager, and K.G. Olsen Self-assembled monolayers and enzyme electrodes: progress, problems and prospects Analytical Chimica Acta 307 1995 277 289
    • (1995) Analytical Chimica Acta , vol.307 , pp. 277-289
    • Creager, S.E.1    Olsen, K.G.2
  • 28
    • 35748931751 scopus 로고    scopus 로고
    • A label-free, microfluidics and interdigitated array microelectrode-based impedance biosensor in combination with nanoparticles immunoseparation for detection of Escherichia coli O157:H7 in food samples
    • DOI 10.1016/j.snb.2007.03.045, PII S0925400507003887
    • M. Varshney, Y. Li, B. Srinivasan, and S. Tung A label-free, microfluidics and interdigitated array microelectrode-based impedance biosensor in combination with nanoparticles immunoseparation for detection of Escherichia coli O157:H7 in food sample Sensors and Actuators B 128 2007 99 107 (Pubitemid 350051796)
    • (2007) Sensors and Actuators, B: Chemical , vol.128 , Issue.1 , pp. 99-107
    • Varshney, M.1    Li, Y.2    Srinivasan, B.3    Tung, S.4
  • 29
    • 29144528944 scopus 로고    scopus 로고
    • A mixed self-assembled monolayer-based surface plasmon immunosensor for detection of E. coli O157:H7
    • DOI 10.1016/j.bios.2005.03.007, PII S0956566305000904
    • A. Subramanian, J. Irudayaraj, and T. Ryan A mixed self-assembled monolayer-based surface plasmon immunosensor for detection of E. coli O157:H7 Biosensors and Bioelectronics 21 2006 998 1006 (Pubitemid 41815107)
    • (2006) Biosensors and Bioelectronics , vol.21 , Issue.7 , pp. 998-1006
    • Subramanian, A.1    Irudayaraj, J.2    Ryan, T.3
  • 30
    • 62649102712 scopus 로고    scopus 로고
    • Detection of Salmonella typhimurium using an electrochemical immunosensor
    • F. Salam, and I.E. Tothill Detection of Salmonella typhimurium using an electrochemical immunosensor Biosensors and Bioelectronics 24 2009 2630 2636
    • (2009) Biosensors and Bioelectronics , vol.24 , pp. 2630-2636
    • Salam, F.1    Tothill, I.E.2
  • 31
    • 0034087466 scopus 로고    scopus 로고
    • Development of a fluorogenic probe-based PCR assay for detection of Bacillus cereus in nonfat dry milk
    • DOI 10.1128/AEM.66.4.1453-1459.2000
    • Y.R. Kim, J. Czajka, and C.A. Batt Development of a fluorogenic probe-based PCR assay for detection of Bacillus cereus in nonfat dry milk Applied and Environmental Microbiology 66 2000 1453 1459 (Pubitemid 30185616)
    • (2000) Applied and Environmental Microbiology , vol.66 , Issue.4 , pp. 1453-1459
    • Kim, Y.-R.1    Czajka, J.2    Batt, C.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.