메뉴 건너뛰기




Volumn 8, Issue 1, 2012, Pages 40-47

Targeted cardiac post-mortem computed tomography angiography: A pictorial review

Author keywords

Angiography; Autopsy; Computed tomography; Forensic; Post mortem; Targeted

Indexed keywords

CONTRAST MEDIUM;

EID: 84856212686     PISSN: 1547769X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s12024-011-9267-0     Document Type: Review
Times cited : (27)

References (16)
  • 1
    • 0020660178 scopus 로고
    • Post-mortem computed tomography in a diving fatality
    • Krant P, Holtas S. Post-mortem computed tomography in a diving fatality. J Comput Assist Tomogr. 1983; 7: 132-4.
    • (1983) J Comput Assist Tomogr , vol.7 , pp. 132-134
    • Krant, P.1    Holtas, S.2
  • 2
    • 79960701531 scopus 로고    scopus 로고
    • The criminal justice system's consideration of so-called "near virtual autopsies"; the east midlands experience
    • (in press)
    • Jeffery A, Morgan B, Raj V, West K, Rutty GN. The criminal justice system's consideration of so-called "near virtual autopsies"; the east midlands experience. J Clin Pathol. 2011; (in press).
    • (2011) J Clin Pathol
    • Jeffery, A.1    Morgan, B.2    Raj, V.3    West, K.4    Rutty, G.N.5
  • 7
    • 41149093071 scopus 로고    scopus 로고
    • Whole body post-mortem angiography with a high viscosity contrast agent solution using poly ethylene glycol as contrast agent dissolver
    • Jackowski C, Persson A, Thali MJ. Whole body post-mortem angiography with a high viscosity contrast agent solution using poly ethylene glycol as contrast agent dissolver. J Forensic Sci. 2008; 53: 465-8.
    • (2008) J Forensic Sci , vol.53 , pp. 465-468
    • Jackowski, C.1    Persson, A.2    Thali, M.J.3
  • 8
    • 24644491195 scopus 로고    scopus 로고
    • Virtopsy: post-mortem minimally invasive angiography using cross section techniques-implementation and preliminary results
    • Jackowski C, Sonnenschein M, Thali MJ, Aghayev E, von Allmen G, Yen K, et al. Virtopsy: post-mortem minimally invasive angiography using cross section techniques-implementation and preliminary results. J Forensic Sci. 2005; 50: 1175-86.
    • (2005) J Forensic Sci , vol.50 , pp. 1175-1186
    • Jackowski, C.1    Sonnenschein, M.2    Thali, M.J.3    Aghayev, E.4    von Allmen, G.5    Yen, K.6
  • 9
    • 39049156814 scopus 로고    scopus 로고
    • Virtual autopsy using imaging: bridging radiologic and forensic sciences. A review of the virtopsy and similar projects
    • Bolliger SA, Thali MJ, Ross S, Buck U, Naether S, Vock P. Virtual autopsy using imaging: bridging radiologic and forensic sciences. A review of the virtopsy and similar projects. Eur Radiol. 2008; 18: 273-82.
    • (2008) Eur Radiol , vol.18 , pp. 273-282
    • Bolliger, S.A.1    Thali, M.J.2    Ross, S.3    Buck, U.4    Naether, S.5    Vock, P.6
  • 11
    • 79960961547 scopus 로고    scopus 로고
    • Post-mortem computed tomography angiography: past, present and future
    • doi: 10. 1007/s12024-010-9208-3
    • Saunders S, Morgan B, Raj V, Rutty G. Post-mortem computed tomography angiography: past, present and future. Forensic Sci Med Pathol. 2010; doi: 10. 1007/s12024-010-9208-3.
    • (2010) Forensic Sci Med Pathol
    • Saunders, S.1    Morgan, B.2    Raj, V.3    Rutty, G.4
  • 12
    • 79960280594 scopus 로고    scopus 로고
    • Targeted post-mortem computed tomography cardiac angiography; proof of concept
    • Saunders S, Morgan B, Robinson C, Raj V, Rutty G. Targeted post-mortem computed tomography cardiac angiography; proof of concept. Int J Legal Med. 2011; 125(4): 609-16.
    • (2011) Int J Legal Med , vol.125 , Issue.4 , pp. 609-616
    • Saunders, S.1    Morgan, B.2    Robinson, C.3    Raj, V.4    Rutty, G.5
  • 13
    • 79957698095 scopus 로고    scopus 로고
    • Diagnosis of coronary artery disease using a minimally invasive autopsy: evaluation of a novel method of post-mortem coronary CT angiography
    • Roberts ISD, Benamore RE, Peebles C, Roobottom C, Traill ZC. Diagnosis of coronary artery disease using a minimally invasive autopsy: evaluation of a novel method of post-mortem coronary CT angiography. Clin Radiol. 2011; 66(7): 645-50.
    • (2011) Clin Radiol , vol.66 , Issue.7 , pp. 645-650
    • Roberts, I.S.D.1    Benamore, R.E.2    Peebles, C.3    Roobottom, C.4    Traill, Z.C.5
  • 14
    • 79960554604 scopus 로고    scopus 로고
    • Post-mortem coronary CT angiography: a Leicester perspective
    • doi: 10. 1016/j. crad. 2011. 04. 005
    • Raj V, Saunders S, Morgan B, Rutty G. Post-mortem coronary CT angiography: a Leicester perspective. Clin Radiol. 2011; doi: 10. 1016/j. crad. 2011. 04. 005.
    • (2011) Clin Radiol
    • Raj, V.1    Saunders, S.2    Morgan, B.3    Rutty, G.4
  • 15
    • 79251644428 scopus 로고    scopus 로고
    • Demonstrating the origin of cardiac air embolism using post-mortem computed tomography; an illustrated case
    • Saunders S, Kotecha D, Morgan B, Raj V, Rutty G. Demonstrating the origin of cardiac air embolism using post-mortem computed tomography; an illustrated case. Leg Med (Tokyo). 2011; 13(2): 79-82.
    • (2011) Leg Med (Tokyo) , vol.13 , Issue.2 , pp. 79-82
    • Saunders, S.1    Kotecha, D.2    Morgan, B.3    Raj, V.4    Rutty, G.5
  • 16
    • 54949112447 scopus 로고    scopus 로고
    • Anthropological measurement of lower limb and foot bones using multi-detector computed tomography
    • Robinson C, Eisma R, Morgan B, Jeffery A, Graham EA, Black S, Rutty GN. Anthropological measurement of lower limb and foot bones using multi-detector computed tomography. J Forensic Sci. 2008; 6: 1289-95.
    • (2008) J Forensic Sci , vol.6 , pp. 1289-1295
    • Robinson, C.1    Eisma, R.2    Morgan, B.3    Jeffery, A.4    Graham, E.A.5    Black, S.6    Rutty, G.N.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.