Relationship between measurement site and motion artifacts in wearable reflected photoplethysmography

Author keywords

Anatomical site; Green light; Infrared light; Motion artifact; PPG

Indexed keywords

ADULT; ANATOMY; ARTIFACT; CONFERENCE PAPER; ELECTROCARDIOGRAPHY; FOREARM; GREEN LIGHT; HUMAN; HUMAN EXPERIMENT; INFRARED LIGHT; JUMPING; LIGHT; MALE; MEASUREMENT; MOTION; MOTION ARTIFACT; NORMAL HUMAN; PHOTOELECTRIC PLETHYSMOGRAPHY; PULSE RATE; RR INTERVAL; SKIN BLOOD FLOW;

EID: 84856211922     PISSN: 01485598     EISSN: 1573689X     Source Type: Journal    
DOI: 10.1007/s10916-010-9505-0     Document Type: Conference Paper
Times cited : (150)

References (11)
  • 1
    • 34247467602 scopus 로고    scopus 로고
    • Photoplethysmography and its application in clinical physiological measurement
    • 10.1088/0967-3334/28/3/R01
    • J Allen 2007 Photoplethysmography and its application in clinical physiological measurement Physiol. Meas. 28 R1 R39 10.1088/0967-3334/28/3/R01
    • (2007) Physiol. Meas. , vol.28
    • Allen, J.1
  • 2
    • 33344472354 scopus 로고    scopus 로고
    • Motion artifact reduction in photoplethysmography using independent component analysis
    • 10.1109/TBME.2005.869784
    • BS Kim SK Yoo 2006 Motion artifact reduction in photoplethysmography using independent component analysis IEEE Trans. Biomed. Eng. 53 566 568 10.1109/TBME.2005.869784
    • (2006) IEEE Trans. Biomed. Eng. , vol.53 , pp. 566-568
    • Kim, B.S.1    Yoo, S.K.2
  • 3
    • 0000573306 scopus 로고    scopus 로고
    • Artifact Reduction in Photoplethysmography
    • 10.1364/AO.37.007437
    • MJ Hayes PR Smith 1998 Artifact Reduction in Photoplethysmography Appl. Opt. 37 7437 7446 10.1364/AO.37.007437
    • (1998) Appl. Opt. , vol.37 , pp. 7437-7446
    • Hayes, M.J.1    Smith, P.R.2
  • 4
    • 18044373423 scopus 로고    scopus 로고
    • Reduction of motion artifact in pulse oximetry by smoothed pseudo Wigner-Ville distribution
    • 10.1186/1743-0003-2-3 Open access
    • Y Yan C Poon Y Zhang 2005 Reduction of motion artifact in pulse oximetry by smoothed pseudo Wigner-Ville distribution J. Neuro Eng. Rehabil. 2 3 10.1186/1743-0003-2-3 Open access
    • (2005) J. Neuro Eng. Rehabil. , vol.2 , pp. 3
    • Yan, Y.1    Poon, C.2    Zhang, Y.3
  • 6
    • 0000696490 scopus 로고
    • The blood supply of various skin areas as estimated by the photoelectric plethysmograph
    • AB Hertzman 1938 The blood supply of various skin areas as estimated by the photoelectric plethysmograph Am. J. Physiol. 124 323 340
    • (1938) Am. J. Physiol. , vol.124 , pp. 323-340
    • Hertzman, A.B.1
  • 7
    • 0042905513 scopus 로고
    • Relations between cutaneous blood flow and blood content in the finger pad, forearm and forehead
    • AB Hertzman WC Randall KE Jochim 1947 Relations between cutaneous blood flow and blood content in the finger pad, forearm and forehead Am. J. Physiol. 150 122 132
    • (1947) Am. J. Physiol. , vol.150 , pp. 122-132
    • Hertzman, A.B.1    Randall, W.C.2    Jochim, K.E.3
  • 8
    • 0006742816 scopus 로고
    • Regional differences in the basal and maxima rates of blood flow in skin
    • AB Hertzman WC Randakk 1948 Regional differences in the basal and maxima rates of blood flow in skin J. Appl. Physiol. 151 234 241
    • (1948) J. Appl. Physiol. , vol.151 , pp. 234-241
    • Hertzman, A.B.1    Randakk, W.C.2
  • 9
    • 0021088458 scopus 로고
    • Basal perfusion of the cutaneous microcirculation: Measurements as a function of anatomical position
    • 10.1111/1523-1747.ep12522619
    • E Tur M Tur HI Maibach RH Guy 1983 Basal perfusion of the cutaneous microcirculation: measurements as a function of anatomical position J. Invetst. Dermatol. 81 442 446 10.1111/1523-1747.ep12522619
    • (1983) J. Invetst. Dermatol. , vol.81 , pp. 442-446
    • Tur, E.1    Tur, M.2    Maibach, H.I.3    Guy, R.H.4
  • 10
    • 0034313775 scopus 로고    scopus 로고
    • Variability of photoplethysmograpy peripheral pulse measurements at the ears, thumbs and toes
    • 10.1049/ip-smt:20000846
    • J Allen A Murray 2000 Variability of photoplethysmograpy peripheral pulse measurements at the ears, thumbs and toes IEE Proc. Sci. Measu. Technol. 147 403 407 10.1049/ip-smt:20000846
    • (2000) IEE Proc. Sci. Measu. Technol. , vol.147 , pp. 403-407
    • Allen, J.1    Murray, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.