메뉴 건너뛰기




Volumn 161, Issue 1, 2012, Pages 669-674

Gold nanoparticles-modified screen-printed carbon electrodes for anodic stripping voltammetric determination of mercury in ambient water samples

Author keywords

Gold nanoparticles; Hg(II); Screen printed electrodes; SWASV; Water

Indexed keywords

AMBIENT WATERS; ANODIC STRIPPING; ELECTROCHEMICAL METHODS; ENVIRONMENTAL WATER; GOLD NANOPARTICLES; NANO STRUCTURATION; NANO-STRUCTURED; RAIN WATER; RIVER WATER; SAMPLE PRETREATMENT; SCREEN PRINTED ELECTRODES; SCREEN-PRINTED CARBON ELECTRODES; SQUARE WAVE ANODIC STRIPPING VOLTAMMETRY; STRIPPING METHODS; SWASV; VOLTAMMETRIC; VOLTAMMETRIC DETERMINATION; WATER STANDARDS;

EID: 84856208954     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2011.10.088     Document Type: Article
Times cited : (76)

References (17)
  • 1
    • 77951630440 scopus 로고    scopus 로고
    • Methods for the determination and speciation of mercury in natural waters - A review
    • K. Leopold, M. Foulkes, and P. Worsfold Methods for the determination and speciation of mercury in natural waters - a review Anal. Chim. Acta 663 2010 127 138
    • (2010) Anal. Chim. Acta , vol.663 , pp. 127-138
    • Leopold, K.1    Foulkes, M.2    Worsfold, P.3
  • 2
    • 0034668007 scopus 로고    scopus 로고
    • Room temperature sonolysis-based advanced oxidation process for degradation of organomercurials: Application to determination of inorganic and total mercury in waters by flow injection-cold vapor atomic absorption spectrometry
    • J.L. Capelo, I. Lavilla, and C. Bendicho Room temperature sonolysis-based advanced oxidation process for degradation of organomercurials: application to determination of inorganic and total mercury in waters by flow injection-cold vapor atomic absorption spectrometry Anal. Chem. 72 2000 4979 4984
    • (2000) Anal. Chem. , vol.72 , pp. 4979-4984
    • Capelo, J.L.1    Lavilla, I.2    Bendicho, C.3
  • 3
    • 38349057376 scopus 로고    scopus 로고
    • Determination of monomethylmercury in low- and high-polluted sediments by microwave extraction and gas chromatography with atomic fluorescence detection
    • J.J. Berzas Nevado, R.C. Rodríguez Martín-Doimeadios, F.J. Guzmán Bernardo, and M. Jiménez Moreno Determination of monomethylmercury in low- and high-polluted sediments by microwave extraction and gas chromatography with atomic fluorescence detection Anal. Chim. Acta 608 2008 30 37
    • (2008) Anal. Chim. Acta , vol.608 , pp. 30-37
    • Berzas Nevado, J.J.1    Rodríguez Martín-Doimeadios, R.C.2    Guzmán Bernardo, F.J.3    Jiménez Moreno, M.4
  • 4
    • 77955339516 scopus 로고    scopus 로고
    • Approach for rapid extraction and speciation of mercury using a microtip ultrasonic probe followed by LC-ICP-MS
    • I. López, S. Cuello, C. Cámara, and Y. Madrid Approach for rapid extraction and speciation of mercury using a microtip ultrasonic probe followed by LC-ICP-MS Talanta 82 2010 594 599
    • (2010) Talanta , vol.82 , pp. 594-599
    • López, I.1    Cuello, S.2    Cámara, C.3    Madrid, Y.4
  • 5
    • 38349037676 scopus 로고    scopus 로고
    • Determination of mercury by anodic stripping voltammetry with a gold nanoparticle-modified glassy carbon electrode
    • O. Abollino, A. Giacomino, M. Malandrino, G. Piscioneri, and E. Mentasti Determination of mercury by anodic stripping voltammetry with a gold nanoparticle-modified glassy carbon electrode Electroanalysis 20 2008 75 83
    • (2008) Electroanalysis , vol.20 , pp. 75-83
    • Abollino, O.1    Giacomino, A.2    Malandrino, M.3    Piscioneri, G.4    Mentasti, E.5
  • 6
    • 77958487920 scopus 로고    scopus 로고
    • Monodispersed Au nanoparticles decorated graphene as an enhanced sensing platform for ultrasensitive stripping voltammetric detection of mercury (II)
    • J. Gong, T. Zhou, D. Song, and L. Zhang Monodispersed Au nanoparticles decorated graphene as an enhanced sensing platform for ultrasensitive stripping voltammetric detection of mercury (II) Sens. Actuators B 150 2010 491 497
    • (2010) Sens. Actuators B , vol.150 , pp. 491-497
    • Gong, J.1    Zhou, T.2    Song, D.3    Zhang, L.4
  • 7
    • 0028066849 scopus 로고
    • Potentiometric stripping determination of mercury(II), selenium(IV), copper(II) and lead(II) at a gold film electrode in water samples
    • E. Pinilla Gil, and P. Ostapczuk Potentiometric stripping determination of mercury(II), selenium(IV), copper(II) and lead(II) at a gold film electrode in water samples Anal. Chim. Acta 293 1994 55
    • (1994) Anal. Chim. Acta , vol.293 , pp. 55
    • Pinilla Gil, E.1    Ostapczuk, P.2
  • 8
    • 0034623683 scopus 로고    scopus 로고
    • Trace determination of mercury by anodic stripping voltammetry at the rotating gold electrode
    • Y. Bonfil, M. Brand, and E. Kirowa-Eisner Trace determination of mercury by anodic stripping voltammetry at the rotating gold electrode Anal. Chim. Acta 424 2000 65 76
    • (2000) Anal. Chim. Acta , vol.424 , pp. 65-76
    • Bonfil, Y.1    Brand, M.2    Kirowa-Eisner, E.3
  • 10
    • 39649096060 scopus 로고    scopus 로고
    • Parameters affecting the determination of mercury by anodic stripping voltammetry using a gold electrode
    • A. Giacomino, O. Abollino, M. Malandrino, and E. Mentasti Parameters affecting the determination of mercury by anodic stripping voltammetry using a gold electrode Talanta 75 2008 266 273
    • (2008) Talanta , vol.75 , pp. 266-273
    • Giacomino, A.1    Abollino, O.2    Malandrino, M.3    Mentasti, E.4
  • 11
    • 72849140901 scopus 로고    scopus 로고
    • The use of nanoparticles in electroanalysis: An updated review
    • F.W. Campbell, and R.G. Compton The use of nanoparticles in electroanalysis: an updated review Anal. Bioanal. Chem. 396 2010 241 259
    • (2010) Anal. Bioanal. Chem. , vol.396 , pp. 241-259
    • Campbell, F.W.1    Compton, R.G.2
  • 12
    • 70349865240 scopus 로고    scopus 로고
    • Voltammetric determination of methylmercury and inorganic mercury with an home made gold nanoparticle electrode
    • O. Abollino, A. Giacomino, M. Malandrino, S. Marro, and E. Mentasti Voltammetric determination of methylmercury and inorganic mercury with an home made gold nanoparticle electrode J. Appl. Electrochem. 39 2009 2209 2216
    • (2009) J. Appl. Electrochem. , vol.39 , pp. 2209-2216
    • Abollino, O.1    Giacomino, A.2    Malandrino, M.3    Marro, S.4    Mentasti, E.5
  • 13
    • 34547737396 scopus 로고    scopus 로고
    • Recent developments in the field of screen-printed electrodes and their related applications
    • O. Domínguez Renedo, M.A. Alonso-Lomillo, and M.J. Arcos Martínez Recent developments in the field of screen-printed electrodes and their related applications Talanta 73 2007 202 219
    • (2007) Talanta , vol.73 , pp. 202-219
    • Domínguez Renedo, O.1    Alonso-Lomillo, M.A.2    Arcos Martínez, M.J.3
  • 14
    • 33244469462 scopus 로고    scopus 로고
    • Gold-based screen-printed sensor for detection of trace lead
    • DOI 10.1016/j.snb.2005.05.028, PII S0925400505005502
    • S. Laschi, I. Palchetti, and M. Mascini Gold-based screen-printed sensor for detection of trace lead Sens. Actuators B 114 2006 460 465 (Pubitemid 43276214)
    • (2006) Sensors and Actuators, B: Chemical , vol.114 , Issue.1 , pp. 460-465
    • Laschi, S.1    Palchetti, I.2    Mascini, M.3
  • 15
    • 57049127627 scopus 로고    scopus 로고
    • An optimized digestion method coupled to electrochemical sensor for the determination of Cd, Cu, Pb and Hg in fish by square wave anodic stripping voltammetry
    • V. Meucci, S. Laschi, M. Minunni, C. Pretti, L. Intorre, G. Soldani, and M. Mascini An optimized digestion method coupled to electrochemical sensor for the determination of Cd, Cu, Pb and Hg in fish by square wave anodic stripping voltammetry Talanta 77 2009 1143 1148
    • (2009) Talanta , vol.77 , pp. 1143-1148
    • Meucci, V.1    Laschi, S.2    Minunni, M.3    Pretti, C.4    Intorre, L.5    Soldani, G.6    Mascini, M.7
  • 16
    • 77956179873 scopus 로고    scopus 로고
    • Stripping voltammetric determination of mercury(II) and lead(II) using screen-printed electrodes modified with gold films, and metal ion preconcentration with thiol-modified magnetic particles
    • A. Mandil, L. Idrissi, and A. Amine Stripping voltammetric determination of mercury(II) and lead(II) using screen-printed electrodes modified with gold films, and metal ion preconcentration with thiol-modified magnetic particles Microchim. Acta 170 2010 299 305
    • (2010) Microchim. Acta , vol.170 , pp. 299-305
    • Mandil, A.1    Idrissi, L.2    Amine, A.3
  • 17
    • 79951684094 scopus 로고    scopus 로고
    • Determination of mercury in ambient water samples by anodic stripping voltammetry on screen-printed gold electrodes
    • E. Bernalte, C. Marín Sánchez, and E. Pinilla Gil Determination of mercury in ambient water samples by anodic stripping voltammetry on screen-printed gold electrodes Anal. Chim. Acta 689 2011 60 64
    • (2011) Anal. Chim. Acta , vol.689 , pp. 60-64
    • Bernalte, E.1    Marín Sánchez, C.2    Pinilla Gil, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.