1
-
-
0027415922
-
The Moncrief-Popovich catheter. A new peritoneal access technique for patients on peritoneal dialysis
-
Moncrief JW, Popovich RP, Broadrick LJ, He ZZ, Simmons EE, Tate RA. The Moncrief-Popovich catheter. A new peritoneal access technique for patients on peritoneal dialysis. ASAIOJ 1993; 39:62-5.
-
(1993)
ASAIOJ
, vol.39
, pp. 62-65
-
-
Moncrief, J.W.1
Popovich, R.P.2
Broadrick, L.J.3
He, Z.Z.4
Simmons, E.E.5
Tate, R.A.6
-
2
-
-
0034031865
-
A simple and inexpensive method of subcutaneous implantation of catheter distal segment using a Tenckhoff curled catheter
-
Page DE, Turpin C. A simple and inexpensive method of subcutaneous implantation of catheter distal segment using a Tenckhoff curled catheter. Perit Dial Int 2000; 20:85-7.
-
(2000)
Perit Dial Int
, vol.20
, pp. 85-87
-
-
Page, D.E.1
Turpin, C.2
-
3
-
-
0027934919
-
Moncrief-Popovich catheter: Implantation technique and clinical results
-
Moncrief JW, Popovich RP. Moncrief-Popovich catheter: implantation technique and clinical results. Perit Dial Int 1994; 14(Suppl 3):S56-8.
-
(1994)
Perit Dial Int
, vol.14
, Issue.SUPPL. 3
-
-
Moncrief, J.W.1
Popovich, R.P.2
-
4
-
-
0027184314
-
Reduction in peritonitis incidence in continuous ambulatory peritoneal dialysis with a new catheter and implantation technique
-
Moncrief JW, Popovich RP, Dasgupta M, Costerton JW, Simmons E, Moncrief B. Reduction in peritonitis incidence in continuous ambulatory peritoneal dialysis with a new catheter and implantation technique. Perit Dial Int 1993; 13(Suppl 2):S329-31.
-
(1993)
Perit Dial Int
, vol.13
, Issue.SUPPL. 2
-
-
Moncrief, J.W.1
Popovich, R.P.2
Dasgupta, M.3
Costerton, J.W.4
Simmons, E.5
Moncrief, B.6
-
5
-
-
0028696994
-
Moncrief's technique for peritoneal catheter placement: Experience of a CAPD unit
-
de Alvaro F, Selgas R, Bajo MA, Serrano P, Fernández-Reyes MJ, del Peso G, et al. Moncrief's technique for peritoneal catheter placement: experience of a CAPD unit. Adv Perit Dial 1994; 10:199-202.
-
(1994)
Adv Perit Dial
, vol.10
, pp. 199-202
-
-
de Alvaro, F.1
Selgas, R.2
Bajo, M.A.3
Serrano, P.4
Fernández-Reyes, M.J.5
del Peso, G.6
-
6
-
-
0027021921
-
Subcutaneously implanted catheters reduce the incidence of peritonitis during CAPD by infection by periluminal route
-
Han DC, Cha HK, So IN, Chung SH, Park MS, Lee SK, et al. Subcutaneously implanted catheters reduce the incidence of peritonitis during CAPD by infection by periluminal route. Adv Perit Dial 1992; 8:298-301.
-
(1992)
Adv Perit Dial
, vol.8
, pp. 298-301
-
-
Han, D.C.1
Cha, H.K.2
So, I.N.3
Chung, S.H.4
Park, M.S.5
Lee, S.K.6
-
7
-
-
0029952359
-
Peritoneal dialysis access technology: The Austin Diagnostic Clinic experience
-
Moncrief JW, Popovich RP, Seare W, Sorrels PA, Moncrief DB, Settle SM, et al. Peritoneal dialysis access technology: the Austin Diagnostic Clinic experience. Perit Dial Int 1996; 16(Suppl 1):S327-9.
-
(1996)
Perit Dial Int
, vol.16
, Issue.SUPPL. 1
-
-
Moncrief, J.W.1
Popovich, R.P.2
Seare, W.3
Sorrels, P.A.4
Moncrief, D.B.5
Settle, S.M.6
-
8
-
-
7344239308
-
Effect of prolonged subcutaneous implantation of peritoneal catheter on peritonitis rate during CAPD: A prospective randomized study
-
Park MS, Yim AS, Chung SH, Lee EY, Cha MK, Kim JH, et al. Effect of prolonged subcutaneous implantation of peritoneal catheter on peritonitis rate during CAPD: a prospective randomized study. Blood Purif 1998; 16:171-8.
-
(1998)
Blood Purif
, vol.16
, pp. 171-178
-
-
Park, M.S.1
Yim, A.S.2
Chung, S.H.3
Lee, E.Y.4
Cha, M.K.5
Kim, J.H.6
-
9
-
-
0036105119
-
A prospective randomized study of the effect of a subcutaneously "buried" peritoneal dialysis catheter technique versus standard technique on the incidence of peritonitis and exit-site infection
-
Danielsson A, Blohmé L, Tranæus A, Hylander B. A prospective randomized study of the effect of a subcutaneously "buried" peritoneal dialysis catheter technique versus standard technique on the incidence of peritonitis and exit-site infection. Perit Dial Int 2002; 22:211-19.
-
(2002)
Perit Dial Int
, vol.22
, pp. 211-219
-
-
Danielsson, A.1
Blohmé, L.2
Tranæus, A.3
Hylander, B.4
-
10
-
-
34447549126
-
A prospective study to compare subcutaneously buried peritoneal dialysis catheter technique with conventional technique
-
Wu CC, Su PF, Chiang SS. A prospective study to compare subcutaneously buried peritoneal dialysis catheter technique with conventional technique. Blood Purif 2007; 25:229-32.
-
(2007)
Blood Purif
, vol.25
, pp. 229-232
-
-
Wu, C.C.1
Su, P.F.2
Chiang, S.S.3
-
11
-
-
0036526551
-
Moncrief-Popovich catheter and implantation technique: The AV fistula of peritoneal dialysis
-
Dasgupta MK. Moncrief-Popovich catheter and implantation technique: the AV fistula of peritoneal dialysis. Adv Ren Replace Ther 2002; 9:116-24.
-
(2002)
Adv Ren Replace Ther
, vol.9
, pp. 116-124
-
-
Dasgupta, M.K.1
-
12
-
-
0033647845
-
Subcutaneously tunnelled peritoneal dialysis catheters with delayed externalization: Long-term follow-up
-
Esson ML, Quinn MJ, Hudson EL, Teitelbaum I. Subcutaneously tunnelled peritoneal dialysis catheters with delayed externalization: long-term follow-up. Adv Perit Dial 2000; 16:123-8.
-
(2000)
Adv Perit Dial
, vol.16
, pp. 123-128
-
-
Esson, M.L.1
Quinn, M.J.2
Hudson, E.L.3
Teitelbaum, I.4
-
13
-
-
46849118058
-
Complications and catheter survival with prolonged embedding of peritoneal dialysis catheters
-
Brown PA, McCormick BB, Knoll G, Su Y, Doucette S, Fergusson D, et al. Complications and catheter survival with prolonged embedding of peritoneal dialysis catheters. Nephrol Dial transplant 2008; 23:2299-303.
-
(2008)
Nephrol Dial transplant
, vol.23
, pp. 2299-2303
-
-
Brown, P.A.1
McCormick, B.B.2
Knoll, G.3
Su, Y.4
Doucette, S.5
Fergusson, D.6
-
14
-
-
77956238383
-
Moncrief-Popovich technique is an advantageous method of peritoneal dialysis catheter implantation
-
Brum S, Rodrigues A, Rocha S, Carvalho MJ, Nogueira C, Magalhães C, et al. Moncrief-Popovich technique is an advantageous method of peritoneal dialysis catheter implantation. Nephrol Dial Transplant 2010; 25:3070-5.
-
(2010)
Nephrol Dial Transplant
, vol.25
, pp. 3070-3075
-
-
Brum, S.1
Rodrigues, A.2
Rocha, S.3
Carvalho, M.J.4
Nogueira, C.5
Magalhães, C.6
-
15
-
-
34547646301
-
Peritoneal changes after exposure to sterile solutions by catheter
-
Flessner MF, Credit K, Henderson K, Vanpelt HM, Potter R, He Z, et al. Peritoneal changes after exposure to sterile solutions by catheter. J Am Soc Nephrol 2007; 18:2294-302.
-
(2007)
J Am Soc Nephrol
, vol.18
, pp. 2294-2302
-
-
Flessner, M.F.1
Credit, K.2
Henderson, K.3
Vanpelt, H.M.4
Potter, R.5
He, Z.6
-
16
-
-
16844387422
-
Peritoneal dialysis-related infections recommendations: 2005 update
-
Piraino B, Bailie GR, Bernardini J, Boeschoten E, Gupta A, Holmes C, et al. Peritoneal dialysis-related infections recommendations: 2005 update. Perit Dial Int 2005; 25:107-31.
-
(2005)
Perit Dial Int
, vol.25
, pp. 107-131
-
-
Piraino, B.1
Bailie, G.R.2
Bernardini, J.3
Boeschoten, E.4
Gupta, A.5
Holmes, C.6
-
17
-
-
0029161116
-
The standard peritoneal permeability analysis: A tool for the assessment of peritoneal permeability characteristics in CAPD patients
-
Pannekeet MM, Imholz AL, Struijk DG, Koomen GC, Langedijk MJ, Schouten N, et al. The standard peritoneal permeability analysis: a tool for the assessment of peritoneal permeability characteristics in CAPD patients. Kidney Int 1995; 48:866-75.
-
(1995)
Kidney Int
, vol.48
, pp. 866-875
-
-
Pannekeet, M.M.1
Imholz, A.L.2
Struijk, D.G.3
Koomen, G.C.4
Langedijk, M.J.5
Schouten, N.6
-
18
-
-
48949117511
-
Use of embedded peritoneal dialysis catheters-a UK perspective and a single center's experience
-
Junejo K, Jeboda F, Chawdhery MZ, Stoby-Field M, Fan SL. Use of embedded peritoneal dialysis catheters-a UK perspective and a single center's experience. Perit Dial Int 2008; 28:305-8.
-
(2008)
Perit Dial Int
, vol.28
, pp. 305-308
-
-
Junejo, K.1
Jeboda, F.2
Chawdhery, M.Z.3
Stoby-Field, M.4
Fan, S.L.5
|