Comparison of long-axis and short-axis PROPELLER-EPI for diffusion-weighted Magnetic Resonance Imaging;Vergleich von Long-Axis- und Short-Axis-PROPELLER-EPI fur die diffusionsgewichtete Magnetresonanztomographie

Author keywords

Diffusion weighted imaging; Echo planar imaging; Long axis; Propeller; Short axis

Indexed keywords

ACCURACY; ARTICLE; CONTROLLED STUDY; DIFFUSION WEIGHTED IMAGING; ECHO PLANAR IMAGING; IMAGE QUALITY; IN VIVO STUDY; INTERMETHOD COMPARISON; PHANTOM; PROCESS OPTIMIZATION; ARTIFACT; BRAIN; COMPARATIVE STUDY; COMPUTER ASSISTED DIAGNOSIS; COMPUTER PROGRAM; HUMAN; IMAGE ENHANCEMENT; METHODOLOGY; PATHOLOGY; PHYSICS; REFERENCE VALUE; SENSITIVITY AND SPECIFICITY; VALIDATION STUDY;

EID: 84856169436     PISSN: 09393889     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.zemedi.2010.05.003     Document Type: Article
Times cited : (4)

References (12)
  • 1
    • 0029034190 scopus 로고
    • Correction for geometric distortion in echo planar images from B0 field variations
    • Jezzard P., Balaban R.S. Correction for geometric distortion in echo planar images from B0 field variations. Magn Reson Med 1995, 34:65-73.
    • (1995) Magn Reson Med , vol.34 , pp. 65-73
    • Jezzard, P.1    Balaban, R.S.2
  • 2
    • 0030802130 scopus 로고    scopus 로고
    • Ghost artifact reduction for echo planar imaging using image phase correction
    • Buonocore M.H., Gao L. Ghost artifact reduction for echo planar imaging using image phase correction. Magn Reson Med 1997, 38:89-100.
    • (1997) Magn Reson Med , vol.38 , pp. 89-100
    • Buonocore, M.H.1    Gao, L.2
  • 3
    • 0028324684 scopus 로고
    • Correction of motional artifacts in diffusion-weighted MR images using navigator echoes
    • Ordidge R.J., Helpern J.A., Qing Z.X., Knight R.A., Nagesh V. Correction of motional artifacts in diffusion-weighted MR images using navigator echoes. Magn Reson Imag 1994, 12:455-460.
    • (1994) Magn Reson Imag , vol.12 , pp. 455-460
    • Ordidge, R.J.1    Helpern, J.A.2    Qing, Z.X.3    Knight, R.A.4    Nagesh, V.5
  • 4
    • 0028030441 scopus 로고
    • Analysis and correction of motion artifacts in diffusion weighted imaging
    • Anderson A.W., Gore J.C. Analysis and correction of motion artifacts in diffusion weighted imaging. Magn Reson Med 1994, 32:379-387.
    • (1994) Magn Reson Med , vol.32 , pp. 379-387
    • Anderson, A.W.1    Gore, J.C.2
  • 5
    • 0032754594 scopus 로고    scopus 로고
    • Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging
    • Pipe J.G. Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging. Magn Reson Med 1999, 42:963-969.
    • (1999) Magn Reson Med , vol.42 , pp. 963-969
    • Pipe, J.G.1
  • 6
    • 27644579499 scopus 로고    scopus 로고
    • PROPELLER EPI: An MRI technique suitable for diffusion tensor imaging at high field strengh with reduced geometric distortion
    • Wang F.N., Huang T.Y., Lin F.H., Chuang T.C., Chen N.K., Chung H.W., Chen H.Y., Kwong K.K. PROPELLER EPI: An MRI technique suitable for diffusion tensor imaging at high field strengh with reduced geometric distortion. Magn Reson Med 2005, 54:1232-1240.
    • (2005) Magn Reson Med , vol.54 , pp. 1232-1240
    • Wang, F.N.1    Huang, T.Y.2    Lin, F.H.3    Chuang, T.C.4    Chen, N.K.5    Chung, H.W.6    Chen, H.Y.7    Kwong, K.K.8
  • 9
    • 0026601923 scopus 로고
    • Image reconstruction for echo planar imaging with nonequidistant k-space sampling
    • Bruder H., Fischer H., Reinfelder H.E., Schmitt F. Image reconstruction for echo planar imaging with nonequidistant k-space sampling. Magn Reson Med 1992, 23:311-323.
    • (1992) Magn Reson Med , vol.23 , pp. 311-323
    • Bruder, H.1    Fischer, H.2    Reinfelder, H.E.3    Schmitt, F.4
  • 10
    • 43949151247 scopus 로고
    • Self-Compensating Pulsed Magnetic-Field Gradients for Short Recovery Times
    • Wider G., Dötsch V., Wüthrich K. Self-Compensating Pulsed Magnetic-Field Gradients for Short Recovery Times. J Magn Reson Med A 1994, 108:255-258.
    • (1994) J Magn Reson Med A , vol.108 , pp. 255-258
    • Wider, G.1    Dötsch, V.2    Wüthrich, K.3
  • 11
    • 0037229177 scopus 로고    scopus 로고
    • Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo
    • Reese T.G., Heid O., Weisskoff R.M., Wedeen V.J. Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo. Magn Reson Med 2003, 49:177-182.
    • (2003) Magn Reson Med , vol.49 , pp. 177-182
    • Reese, T.G.1    Heid, O.2    Weisskoff, R.M.3    Wedeen, V.J.4
  • 12
    • 0034666859 scopus 로고    scopus 로고
    • Temperature-dependent self-diffusion coefficients of water and six selected molecular liquids for calibration in accurate 1H NMR PFG measurements
    • Holz M., Heil S.R., Sacco A. Temperature-dependent self-diffusion coefficients of water and six selected molecular liquids for calibration in accurate 1H NMR PFG measurements. Phys Chem Chem Phys 2000, 2:4740-4742.
    • (2000) Phys Chem Chem Phys , vol.2 , pp. 4740-4742
    • Holz, M.1    Heil, S.R.2    Sacco, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.