메뉴 건너뛰기




Volumn 55, Issue 2, 2012, Pages 428-436.e6

Mesenteric/celiac duplex ultrasound interpretation criteria revisited

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTERIOGRAPHY; ARTICLE; CELIAC ANGIOGRAPHY; CELIAC ARTERY; CELIAC ARTERY STENOSIS; DIAGNOSTIC ACCURACY; ECHOGRAPHY; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MALE; MESENTERIC ARTERY; MESENTERY ANGIOGRAPHY; PREDICTIVE VALUE; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY; SUPERIOR MESENTERIC ARTERY; SUPERIOR MESENTERIC ARTERY OBSTRUCTION;

EID: 84856097922     PISSN: 07415214     EISSN: 10976809     Source Type: Journal    
DOI: 10.1016/j.jvs.2011.08.052     Document Type: Article
Times cited : (72)

References (10)
  • 1
    • 0022635987 scopus 로고
    • Use of hemodynamic parameters in the diagnosis of mesenteric insufficiency
    • DOI 10.1067/mva.1986.avs0030507
    • S.C. Nicholls, T.R. Kohler, R.L. Martin, D.E. Strandness Jr Use of hemodynamic parameters in the diagnosis of mesenteric insufficiency J Vasc Surg 3 1986 507 510 (Pubitemid 16164056)
    • (1986) Journal of Vascular Surgery , vol.3 , Issue.3 , pp. 507-510
    • Nicholls, S.C.1    Kohler, T.R.2    Martin, R.L.3
  • 7
    • 0030741984 scopus 로고    scopus 로고
    • Importance of diastolic velocities in the detection of celiac and mesenteric artery disease by duplex ultrasound
    • DOI 10.1016/S0741-5214(97)70191-5
    • M.J. Perko, S. Just, T.V. Schroeder Importance of diastolic velocities in the detection of celiac and mesenteric artery disease by duplex ultrasound J Vasc Surg 26 1997 288 293 (Pubitemid 27362666)
    • (1997) Journal of Vascular Surgery , vol.26 , Issue.2 , pp. 288-293
    • Perko, M.J.1    Just, S.2    Schroeder, T.V.3
  • 8
    • 64749085422 scopus 로고    scopus 로고
    • Ultrasound assessment of the mesenteric arteries
    • M.V. Revzin, J.S. Pellerito Ultrasound assessment of the mesenteric arteries Ultrasound Clin 2 2007 477 492
    • (2007) Ultrasound Clin , vol.2 , pp. 477-492
    • Revzin, M.V.1    Pellerito, J.S.2
  • 9
    • 0023710206 scopus 로고
    • Comparing the areas under two or more correlated receiver operating characteristic curves: A nonparametric approach
    • E.R. DeLong, D.M. DeLong, D.L. Clarke-Pearson Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach Biometrics 44 1988 837 845
    • (1988) Biometrics , vol.44 , pp. 837-845
    • Delong, E.R.1    Delong, D.M.2    Clarke-Pearson, D.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.