메뉴 건너뛰기




Volumn 32, Issue 3, 2011, Pages 33-43

SOFC-based micro-CHP system as an example of efficient power generation unit

Author keywords

Modeling; Power system; SOFC

Indexed keywords

ASPEN PLUS; COMBINED HEAT AND POWER UNITS; EFFICIENT POWER; ELECTRICAL EFFICIENCY; ENGINEERING SOFTWARE; FUEL PROCESSING; GRID-CONNECTED; MICRO-CHP; MICRO-SCALES; OPERATION PRINCIPLES; OVERALL EFFICIENCY; POTENTIAL MARKETS; STEADY-STATE OPERATION; SUSTAINABLE ENERGY; TECHNOLOGY DEVELOPMENT;

EID: 84856095690     PISSN: 12310956     EISSN: 20836023     Source Type: Journal    
DOI: 10.2478/v10173-011-0011-7     Document Type: Article
Times cited : (40)

References (14)
  • 1
    • 1542304730 scopus 로고    scopus 로고
    • Biogas as a fuel source for SOFC co-generators
    • DOI 10.1016/j.jpowsour.2003.09.027
    • Van Heerle J., Membrez Y., and Bucheli O.: Biogas as a fuel source for SOFC co-generators. J. Power Sources 127(2004), 300-312. (Pubitemid 41325733)
    • (2004) Journal of Power Sources , vol.127 , Issue.1-2 , pp. 300-312
    • Van Herle, J.1    Membrez, Y.2    Bucheli, O.3
  • 2
    • 34248510047 scopus 로고    scopus 로고
    • A thermodynamic analysis of a biogas-fired integrated gasification steam injected gas turbine (BIG/STIG) plant
    • DOI 10.1016/j.applthermaleng.2005.07.027, PII S1359431105002760, Heat Powered Cycles - 04
    • Layi Fagbenle R., Oguaka A.B.C., Olakoyejo O.T.: Thermodynamic analysis of a biogas-fired intefrated gasification steam injected gas turbine (BIG/STIG) plant. Appl. Therm. Eng 27(2005), 2220-2225. (Pubitemid 46754953)
    • (2007) Applied Thermal Engineering , vol.27 , Issue.13 , pp. 2220-2225
    • Fagbenle, R.L.1    Oguaka, A.B.C.2    Olakoyejo, O.T.3
  • 3
    • 79951577008 scopus 로고    scopus 로고
    • An energetic-exergetic comparison between PEMFC and SOFC-based micro-CHP systems
    • Barelli L., Bidini G., Gallorini F., Ottaviano A.: An energetic-exergetic comparison between PEMFC and SOFC-based micro-CHP systems. Int. J. Hydrogen Energy 36 (2011), 3206-3214.
    • (2011) Int. J. Hydrogen Energy , vol.36 , pp. 3206-3214
    • Barelli, L.1    Bidini, G.2    Gallorini, F.3    Ottaviano, A.4
  • 8
    • 84856096935 scopus 로고    scopus 로고
    • personal communication IX
    • Toshiyki U.: JX Nippon, personal communication, IX 2011.
    • (2011) JX Nippon
    • Toshiyki, U.1
  • 10
    • 14944339951 scopus 로고    scopus 로고
    • EG&G Technical Services, Inc. Under Contract No. DE-AM26-99FT40575. U.S. Department of Energy
    • Fuel Cell Handbook, 7th edn. EG&G Technical Services, Inc. Under Contract No. DE-AM26-99FT40575. U.S. Department of Energy, 2004.
    • (2004) Fuel Cell Handbook, 7th Edn
  • 11
    • 0030908403 scopus 로고    scopus 로고
    • Exergy analysis of solid-oxide fuel-cell (SOFC) systems
    • DOI 10.1016/S0360-5442(96)00119-3, PII S0360544296001193
    • Bedringas K.W., Ertesvag I.S., Byggstoyl S., Magnussen B.F.: Exergy analysis of solid-oxide fuell-cell systems. Energy 22(1997), 4, 403-412. (Pubitemid 27210558)
    • (1997) Energy , vol.22 , Issue.4 , pp. 403-412
    • Bedringas, K.W.1    Ertesvag, I.S.2    Byggstoyl, S.3    Magnussen, B.F.4
  • 12
    • 84856078984 scopus 로고    scopus 로고
    • Evaluation and selection of fuel processing technology for SOFC-based micro-CHP unit in dispersed generation
    • ISBN: 978-83-927680-7-4, Nałȩczow, Poland (In Polish)
    • Kupecki J., Jewulski J., Badyda K.: Evaluation and selection of fuel processing technology for SOFC-based micro-CHP unit in dispersed generation. In: Rynek Ciepła - Materiały i Studia, ISBN: 978-83-927680-7-4, 2011, Nałȩczow, Poland (in Polish).
    • (2011) Rynek Ciepła - Materiały i Studia
    • Kupecki, J.1    Jewulski, J.2    Badyda, K.3
  • 14
    • 84856084590 scopus 로고    scopus 로고
    • National Renewable Energy Laboratory. 1-10 kW Stationary Combined Heat and Power Systems Status and Technical Potential NREL/BK-6A10-48265 2010
    • National Renewable Energy Laboratory. 1-10 kW Stationary Combined Heat and Power Systems Status and Technical Potential. NREL/BK-6A10-48265, 2010.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.