메뉴 건너뛰기




Volumn 57, Issue 3, 2012, Pages 649-663

An experimental investigation into the effect of periodic motion on proton dosimetry using polymer gel dosimeters and a programmable motion platform

Author keywords

[No Author keywords available]

Indexed keywords

CYLINDRICAL TARGET; DOSE DISTRIBUTIONS; DOSE-VOLUME HISTOGRAMS; DOSIMETRIC IMPACT; EXPERIMENTAL INVESTIGATIONS; GEL DOSIMETER; INDEX CALCULATION; MOTION MODELS; MOTION PLATFORMS; MOTION PROFILE; ORGAN MOTION; PERIODIC MOTION; POLYMER GEL DOSIMETER; PROTON THERAPY; PROTON TREATMENT; TARGET COVERAGE; TARGET MOTIONS; TREATMENT PLANNING SYSTEMS; TREATMENT PLANS;

EID: 84856089416     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/57/3/649     Document Type: Article
Times cited : (5)

References (14)
  • 1
    • 42449147956 scopus 로고    scopus 로고
    • Quantification of interplay effects of scanned particle beams and moving targets
    • DOI 10.1088/0031-9155/53/9/003, PII S003191550865928X
    • Bert C, Grozinger S O and Rietzel E 2008 Quantification of interplay effects of scanned particle beams and moving targets Phys. Med. Biol. 53 225365 (Pubitemid 351570909)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.9 , pp. 2253-2265
    • Bert, C.1    Grozinger, S.O.2    Rietzel, E.3
  • 3
    • 73649119897 scopus 로고    scopus 로고
    • Commissioning of the discrete spot scanning proton beam delivery system at the University of Texas M D Anderson Cancer Center, Proton Therapy Center, Houston
    • Gillin M T et al 2010 Commissioning of the discrete spot scanning proton beam delivery system at the University of Texas M D Anderson Cancer Center, Proton Therapy Center, Houston Med. Phys. 37 15463
    • (2010) Med. Phys. , vol.37 , Issue.1 , pp. 154-163
    • Gillin, M.T.1
  • 4
    • 4644290784 scopus 로고    scopus 로고
    • Linear energy transfer dependence of a normoxic polymer gel dosimeter investigated using proton beam absorbed dose measurements
    • DOI 10.1088/0031-9155/49/17/002, PII S0031915504777829
    • Gustavsson H, Back S A, Medin J, Grusell E and Olsson L E 2004 Linear energy transfer dependence of a normoxic polymer gel dosimeter investigated using proton beam absorbed dose measurements Phys. Med. Biol. 49 384755 (Pubitemid 39263634)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.17 , pp. 3847-3855
    • Gustavsson, H.1    Back, S.A.J.2    Medin, J.3    Grusell, E.4    Olsson, L.E.5
  • 5
    • 0038715468 scopus 로고    scopus 로고
    • Use of BANG polymer gel for dose measurements in a 68 MeV proton beam
    • DOI 10.1118/1.1575557
    • Heufelder J, Stiefel S, Pfaender M, Ludemann L, Grebe G and Heese J 2003 Use of BANG polymer gel for dose measurements in a 68 MeV proton beam Med. Phys. 30 123540 (Pubitemid 36735990)
    • (2003) Medical Physics , vol.30 , Issue.6 , pp. 1235-1240
    • Heufelder, J.1    Stiefel, S.2    Pfaender, M.3    Ludemann, L.4    Grebe, G.5    Heese, J.6
  • 6
    • 42949093038 scopus 로고    scopus 로고
    • Quantifying the interplay effect in prostate IMRT delivery using a convolution-based method
    • DOI 10.1118/1.2897972
    • Li H S, Chetty I J and Solberg T D 2008 Quantifying the interplay effect in prostate IMRT delivery using a convolution-based method Med. Phys. 35 170310 (Pubitemid 351614784)
    • (2008) Medical Physics , vol.35 , Issue.5 , pp. 1703-1710
    • Li, H.S.1    Chetty, I.J.2    Solberg, T.D.3
  • 8
    • 77952412274 scopus 로고    scopus 로고
    • Dosimetric validation of the proton sensitive BANG3-Pro2 polymer gel dosimeter irradiated by single field therapeutic proton beams
    • Lopatiuk-Tirpak O, Hsi W, Meeks S, Maryanski M, Kupelian P and Zeidan O 2009 Dosimetric validation of the proton sensitive BANG3-Pro2 polymer gel dosimeter irradiated by single field therapeutic proton beams Med. Phys. 36 2733 [Abstract]
    • (2009) Med. Phys. , vol.36 , Issue.6 , pp. 2733
    • Lopatiuk-Tirpak, O.1    Hsi, W.2    Meeks, S.3    Maryanski, M.4    Kupelian, P.5    Zeidan, O.6
  • 9
    • 50449105737 scopus 로고    scopus 로고
    • Performance evaluation of an improved optical computed tomography polymer gel dosimeter system for 3D dose verification of static and dynamic phantom deliveries
    • Lopatiuk-Tirpak O, Langen K M, Meeks S L, Kupelian P A, Zeidan O A and Maryanski M J 2008 Performance evaluation of an improved optical computed tomography polymer gel dosimeter system for 3D dose verification of static and dynamic phantom deliveries Med. Phys. 35 384759
    • (2008) Med. Phys. , vol.35 , Issue.9 , pp. 3847-3859
    • Lopatiuk-Tirpak, O.1    Langen, K.M.2    Meeks, S.L.3    Kupelian, P.A.4    Zeidan, O.A.5    Maryanski, M.J.6
  • 10
    • 0031861573 scopus 로고    scopus 로고
    • A technique for the quantitative evaluation of dose distributions
    • DOI 10.1118/1.598248
    • Low D A, Harms W B, Mutic S and Purdy J A 1998 A technique for the quantitative evaluation of dose distributions Med. Phys. 25 65661 (Pubitemid 28234885)
    • (1998) Medical Physics , vol.25 , Issue.5 , pp. 656-661
    • Low, D.A.1    Harms, W.B.2    Mutic, S.3    Purdy, J.A.4
  • 11
    • 33847629172 scopus 로고    scopus 로고
    • Effects of organ motion on IMRT treatments with segments of few monitor units
    • DOI 10.1118/1.2436972
    • Seco J, Sharp G C, Turcotte J, Gierga D, Bortfeld T and Paganetti H 2007 Effects of organ motion on IMRT treatments with segments of few monitor units Med. Phys. 34 92334 (Pubitemid 46355656)
    • (2007) Medical Physics , vol.34 , Issue.3 , pp. 923-934
    • Seco, J.1    Sharp, G.C.2    Turcotte, J.3    Gierga, D.4    Bortfeld, T.5    Paganetti, H.6
  • 12
    • 69549138159 scopus 로고    scopus 로고
    • The M D Anderson proton therapy system
    • Smith A et al 2009 The M D Anderson proton therapy system Med. Phys. 36 406883
    • (2009) Med. Phys. , vol.36 , Issue.9 , pp. 4068-4083
    • Smith, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.