메뉴 건너뛰기




Volumn 45, Issue 3, 2012, Pages 555-561

Inter-electrode spacing of surface EMG sensors: Reduction of crosstalk contamination during voluntary contractions

Author keywords

Crosstalk; Electrode spacing; EMG sensor; EMG signal

Indexed keywords

BAR ELECTRODES; BAR SENSOR; CROSSTALK CONTAMINATIONS; DISK ELECTRODE; DOUBLE DIFFERENTIAL; ELECTRODE SPACING; ELECTROMYOGRAPHIC; EMG SIGNAL; FORCE MAGNITUDE; GAIT STUDY; INTER-ELECTRODE SPACING; ISOMETRIC CONTRACTIONS; MUSCLE CONTRACTIONS; SINGLE-DIFFERENTIAL; SURFACE EMG; TIBIALIS ANTERIOR; TRICEPS SURAE MUSCLE; VOLUNTARY CONTRACTION;

EID: 84856054343     PISSN: 00219290     EISSN: 18732380     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2011.11.010     Document Type: Article
Times cited : (151)

References (17)
  • 1
    • 21644483603 scopus 로고    scopus 로고
    • Firing rates of motor units in human Vastus Lateralis muscle during fatiguing isometric contractions
    • Adam A., De Luca C.J. Firing rates of motor units in human Vastus Lateralis muscle during fatiguing isometric contractions. Journal of Applied Physiology 2005, 99:268-280.
    • (2005) Journal of Applied Physiology , vol.99 , pp. 268-280
    • Adam, A.1    De Luca, C.J.2
  • 2
    • 77956722136 scopus 로고    scopus 로고
    • Surface electromyography does not accurately reflect rectus femoris activity during gait: impact of speed and crouch on vasti-to-rectus crosstalk
    • Barr K.M., Miller A.L., Chapin K.B. Surface electromyography does not accurately reflect rectus femoris activity during gait: impact of speed and crouch on vasti-to-rectus crosstalk. Gait and Posture 2010, 32:363-368.
    • (2010) Gait and Posture , vol.32 , pp. 363-368
    • Barr, K.M.1    Miller, A.L.2    Chapin, K.B.3
  • 6
    • 0021834117 scopus 로고
    • Myoelectric signal conduction velocity and spectral parameters: influence of force and time
    • Broman H., Bilotto G., De Luca C.J. Myoelectric signal conduction velocity and spectral parameters: influence of force and time. Journal of Applied Physiology 1985, 58:1428-1437.
    • (1985) Journal of Applied Physiology , vol.58 , pp. 1428-1437
    • Broman, H.1    Bilotto, G.2    De Luca, C.J.3
  • 8
    • 0030973129 scopus 로고    scopus 로고
    • The use of surface electromyography in biomechanics
    • De Luca C.J. The use of surface electromyography in biomechanics. Journal of Applied Biomechanics 1997, 13:135-163.
    • (1997) Journal of Applied Biomechanics , vol.13 , pp. 135-163
    • De Luca, C.J.1
  • 9
    • 77952585653 scopus 로고    scopus 로고
    • Filtering the surface EMG signal: movement artifact and baseline noise contamination
    • De Luca C.J., Gilmore D.L., Kuznetsov M., Roy S.H. Filtering the surface EMG signal: movement artifact and baseline noise contamination. Journal of Biomechanics 2010, 43:1573-1579.
    • (2010) Journal of Biomechanics , vol.43 , pp. 1573-1579
    • De Luca, C.J.1    Gilmore, D.L.2    Kuznetsov, M.3    Roy, S.H.4
  • 10
    • 0036842126 scopus 로고    scopus 로고
    • Surface EMG crosstalk between knee extensor muscles: experimental and model results
    • Farina D., Merletti R., Indino B., Nazzaro M. Surface EMG crosstalk between knee extensor muscles: experimental and model results. Muscle and Nerve 2002, 26:681-695.
    • (2002) Muscle and Nerve , vol.26 , pp. 681-695
    • Farina, D.1    Merletti, R.2    Indino, B.3    Nazzaro, M.4
  • 12
    • 33750366208 scopus 로고    scopus 로고
    • Amplitude threshold criteria improve surface electrode specificity during walking and functional movements
    • Johnson M.E., Radtka S.A. Amplitude threshold criteria improve surface electrode specificity during walking and functional movements. Gait and Posture 2006, 24:429-434.
    • (2006) Gait and Posture , vol.24 , pp. 429-434
    • Johnson, M.E.1    Radtka, S.A.2
  • 13
    • 0026928529 scopus 로고
    • Cross talk in surface electromyograms of human hamstring muscles
    • Koh T.J., Grabiner M.D. Cross talk in surface electromyograms of human hamstring muscles. Journal of Orthopedic Research 1992, 10:701-709.
    • (1992) Journal of Orthopedic Research , vol.10 , pp. 701-709
    • Koh, T.J.1    Grabiner, M.D.2
  • 14
    • 0019514716 scopus 로고
    • Surface versus intramuscular electrodes for electromyography of superficial and deep muscles
    • Perry J., Easterday C.S., Antonelli D.J. Surface versus intramuscular electrodes for electromyography of superficial and deep muscles. Physical Therapy 1981, 61:7-15.
    • (1981) Physical Therapy , vol.61 , pp. 7-15
    • Perry, J.1    Easterday, C.S.2    Antonelli, D.J.3
  • 16
    • 0035078460 scopus 로고    scopus 로고
    • A convenient method to reduce crosstalk in surface EMG
    • van Vugt J.P.P., van Dijk J.G. A convenient method to reduce crosstalk in surface EMG. Clinical Neurophysiology 2001, 112:583-592.
    • (2001) Clinical Neurophysiology , vol.112 , pp. 583-592
    • van Vugt, J.P.P.1    van Dijk, J.G.2
  • 17
    • 0020438293 scopus 로고
    • Effect of electrode geometry on the selectivity of myoelectric recordings with surface electrodes
    • Zipp P. Effect of electrode geometry on the selectivity of myoelectric recordings with surface electrodes. European Journal of Applied Physiology and Occupational Physiology 1982, 50:25-40.
    • (1982) European Journal of Applied Physiology and Occupational Physiology , vol.50 , pp. 25-40
    • Zipp, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.