메뉴 건너뛰기




Volumn 97, Issue 5, 2011, Pages 471-478

Dorsally displaced extra-articular distal radius fractures fixation: Dorsal IM nailing versus volar plating. A randomized controlled trial

Author keywords

Distal radius; Dorsal nail; Volar plate

Indexed keywords

ADULT; ARTICLE; BODY POSTURE; BONE RADIOGRAPHY; CLINICAL ARTICLE; CONTROLLED STUDY; EXTRAARTICULAR DISTAL RADIUS FRACTURE; FEMALE; FOLLOW UP; FRACTURE FIXATION; HUMAN; INTERMETHOD COMPARISON; INTRAMEDULLARY NAILING; MALE; PATIENT SATISFACTION; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; PROSPECTIVE STUDY; RADIUS FRACTURE; RANDOMIZED CONTROLLED TRIAL; RANGE OF MOTION; VOLAR PLATE FIXATION;

EID: 84855993251     PISSN: None     EISSN: 18770568     Source Type: Journal    
DOI: 10.1016/j.otsr.2010.11.011     Document Type: Article
Times cited : (30)

References (30)
  • 1
    • 0030459479 scopus 로고    scopus 로고
    • Different risk profiles for hip fractures and distal forearm fractures: a prospective study
    • Graafmans W.C., Ooms .M.E., Bezemer P.D., Bouter L.M., Lips P. Different risk profiles for hip fractures and distal forearm fractures: a prospective study. Osteopor Int 1996, 6:427-431.
    • (1996) Osteopor Int , vol.6 , pp. 427-431
    • Graafmans, W.C.1    Ooms, M.E.2    Bezemer, P.D.3    Bouter, L.M.4    Lips, P.5
  • 2
    • 0141889322 scopus 로고    scopus 로고
    • Functional outcome and complications following two types of dorsal plating for unstable fractures of the distal part of the radius
    • Rozental T.D., Beredjiklian P.K., Bozentka D.J. Functional outcome and complications following two types of dorsal plating for unstable fractures of the distal part of the radius. J Bone Joint Surg (Am) 2003, 85:1956-1960.
    • (2003) J Bone Joint Surg (Am) , vol.85 , pp. 1956-1960
    • Rozental, T.D.1    Beredjiklian, P.K.2    Bozentka, D.J.3
  • 3
    • 33646506008 scopus 로고    scopus 로고
    • Volar fixation of dorsally angulated extra-articular fractures of the distal radius: a biomechanical study
    • Koh S., Morris R.P., Patterson R.M., Kearney J.P., Buford W.L., Viegas S.F. Volar fixation of dorsally angulated extra-articular fractures of the distal radius: a biomechanical study. J Hand Surg 2006, 31 A:771-779.
    • (2006) J Hand Surg , vol.31 A , pp. 771-779
    • Koh, S.1    Morris, R.P.2    Patterson, R.M.3    Kearney, J.P.4    Buford, W.L.5    Viegas, S.F.6
  • 4
    • 58149380678 scopus 로고    scopus 로고
    • Does a volar locking plate provide equivalent stability as a dorsal non-locking plate in a dorsally comminuted distal radius fracture? A biomechanical study
    • Kandemir U., Matityahu A., Desai R., Puttlitz C. Does a volar locking plate provide equivalent stability as a dorsal non-locking plate in a dorsally comminuted distal radius fracture? A biomechanical study. J Orthop Trauma 2008, 22:605-610.
    • (2008) J Orthop Trauma , vol.22 , pp. 605-610
    • Kandemir, U.1    Matityahu, A.2    Desai, R.3    Puttlitz, C.4
  • 5
    • 16244400503 scopus 로고    scopus 로고
    • A biomechanical comparison of a dorsal 3.5mm T-plate and a volar fixed angle plate in a model of dorsally unstable distal radius fractures
    • Liporace F.A., Gupta S., Jeong G.K., Stracher M., Kummer F., Egol K.A., et al. A biomechanical comparison of a dorsal 3.5mm T-plate and a volar fixed angle plate in a model of dorsally unstable distal radius fractures. J Orthop Trauma 2005, 19:187-191.
    • (2005) J Orthop Trauma , vol.19 , pp. 187-191
    • Liporace, F.A.1    Gupta, S.2    Jeong, G.K.3    Stracher, M.4    Kummer, F.5    Egol, K.A.6
  • 6
    • 34250889457 scopus 로고    scopus 로고
    • Volar versus dorsal fixed angle fixation of dorsally unstable extra-articular distal radius fractures: a biomechanical study
    • McCall T.A., Conrad B., Badman B., Wright T. Volar versus dorsal fixed angle fixation of dorsally unstable extra-articular distal radius fractures: a biomechanical study. J Hand Surg 2007, 32 A:806-812.
    • (2007) J Hand Surg , vol.32 A , pp. 806-812
    • McCall, T.A.1    Conrad, B.2    Badman, B.3    Wright, T.4
  • 7
    • 0037244095 scopus 로고    scopus 로고
    • Comparison of different distal radius dorsal and volar fracture fixation plates: a biomechanical study
    • Osada D., Viegas S.F., Shah M.A., Morris R.P., Patterson R.M. Comparison of different distal radius dorsal and volar fracture fixation plates: a biomechanical study. J Hand Surg 2003, 28A:94-104.
    • (2003) J Hand Surg , vol.28 A , pp. 94-104
    • Osada, D.1    Viegas, S.F.2    Shah, M.A.3    Morris, R.P.4    Patterson, R.M.5
  • 8
    • 33750802999 scopus 로고    scopus 로고
    • Internal fixation of dorsally displaced fractures of the distal part of the radius. A biomechanical analysis of volar plate stability
    • Willis A.A., Kutsumi K., Zobitz M.E., Cooney W.P. Internal fixation of dorsally displaced fractures of the distal part of the radius. A biomechanical analysis of volar plate stability. J Bone Joint Surg (Am) 2006, 88:2411-2417.
    • (2006) J Bone Joint Surg (Am) , vol.88 , pp. 2411-2417
    • Willis, A.A.1    Kutsumi, K.2    Zobitz, M.E.3    Cooney, W.P.4
  • 9
    • 25444480002 scopus 로고    scopus 로고
    • Fixed angle fixation of distal radius fracture through a minimally invasive approach
    • Orbay J., Touhami A., Orbay C. Fixed angle fixation of distal radius fracture through a minimally invasive approach. Tech Hand Upper Extrem Surg 2005, 9:142-148.
    • (2005) Tech Hand Upper Extrem Surg , vol.9 , pp. 142-148
    • Orbay, J.1    Touhami, A.2    Orbay, C.3
  • 10
    • 84855988590 scopus 로고    scopus 로고
    • Ostéosynthèse par clou-plaque postérieur des fractures à bascule postérieure: étude prospective à propos de 27cas
    • Sauramps Médical, Y. Allieu, J.L. Roux, G. Meyer Zu Reckendorf (Eds.)
    • Kaba L., Teboul F., Dubert T., Goubier J.N. Ostéosynthèse par clou-plaque postérieur des fractures à bascule postérieure: étude prospective à propos de 27cas. Fractures du radius distal chez l'adulte 2006, 137-146. Sauramps Médical. Y. Allieu, J.L. Roux, G. Meyer Zu Reckendorf (Eds.).
    • (2006) Fractures du radius distal chez l'adulte , pp. 137-146
    • Kaba, L.1    Teboul, F.2    Dubert, T.3    Goubier, J.N.4
  • 11
    • 0014176114 scopus 로고
    • Fracture of the distal radius including sequelae-shoulder-hand-finger syndrome, disturbance in the distal radio-ulnar joint and impairment of nerve function.
    • Acta Orthop Scand
    • Frykman G. Fracture of the distal radius including sequelae-shoulder-hand-finger syndrome, disturbance in the distal radio-ulnar joint and impairment of nerve function. Acta Orthop Scand 1967;Suppl. 108:3.
    • (1967) , Issue.SUPPL. , pp. 108-3
    • Frykman, G.1
  • 12
    • 0029954867 scopus 로고    scopus 로고
    • Development of an upper extremity outcome measure: the DASH (disabilities of the arm, shoulder and hand)
    • Hudak P.L., Amadio P.C., Bombardier C. Development of an upper extremity outcome measure: the DASH (disabilities of the arm, shoulder and hand). Am J Ind Med 1996, 29:602-608.
    • (1996) Am J Ind Med , vol.29 , pp. 602-608
    • Hudak, P.L.1    Amadio, P.C.2    Bombardier, C.3
  • 13
    • 57149142503 scopus 로고    scopus 로고
    • Intramedullary fixation of displaced distal radius fractures: a preliminary report
    • Ilyas A.M., Thoder J.J. Intramedullary fixation of displaced distal radius fractures: a preliminary report. J Hand Surg 2008, 33A:1706-1715.
    • (2008) J Hand Surg , vol.33 A , pp. 1706-1715
    • Ilyas, A.M.1    Thoder, J.J.2
  • 14
    • 33646846631 scopus 로고    scopus 로고
    • Internal fixation of distal radius fractures with novel intramedullary implants
    • Brooks K.R., Capo J.T., Warburton M., Tan V. Internal fixation of distal radius fractures with novel intramedullary implants. Clin Orthop Rel Res 2006, 445:42-50.
    • (2006) Clin Orthop Rel Res , vol.445 , pp. 42-50
    • Brooks, K.R.1    Capo, J.T.2    Warburton, M.3    Tan, V.4
  • 15
    • 0036241905 scopus 로고    scopus 로고
    • Palmar plating for dorsally displaced fractures of the distal radius
    • Kamano M., Honda Y., Kazuki K., Yasuda M. Palmar plating for dorsally displaced fractures of the distal radius. Clin Orthop Rel Res 2002, 397:403-408.
    • (2002) Clin Orthop Rel Res , vol.397 , pp. 403-408
    • Kamano, M.1    Honda, Y.2    Kazuki, K.3    Yasuda, M.4
  • 16
    • 0742270693 scopus 로고    scopus 로고
    • Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient
    • Orbay J.L., Fernandez D.L. Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand Surg 2004, 29A:96-102.
    • (2004) J Hand Surg , vol.29 A , pp. 96-102
    • Orbay, J.L.1    Fernandez, D.L.2
  • 17
    • 22544478434 scopus 로고    scopus 로고
    • Volar fixation of dorsally displaced distal radius fractures using the 2.4mm locking compression plates
    • Musgarve D.S., Idler R.S. Volar fixation of dorsally displaced distal radius fractures using the 2.4mm locking compression plates. J Hand Surg 2005, 30A:743-749.
    • (2005) J Hand Surg , vol.30 A , pp. 743-749
    • Musgarve, D.S.1    Idler, R.S.2
  • 18
    • 33644794928 scopus 로고    scopus 로고
    • Volar fixation of dorsally displaced distal radial fracture using locking compression plate
    • Wong K.K., Chan K.W., Kwok T.K., Mak K.H. Volar fixation of dorsally displaced distal radial fracture using locking compression plate. J Orthop Surg 2005, 13:153-157.
    • (2005) J Orthop Surg , vol.13 , pp. 153-157
    • Wong, K.K.1    Chan, K.W.2    Kwok, T.K.3    Mak, K.H.4
  • 20
    • 33644649770 scopus 로고    scopus 로고
    • Functional outcome and complications after volar plating for dorsally displaced unstable fractures of the distal radius
    • Rozental T.D., Blazar P.E. Functional outcome and complications after volar plating for dorsally displaced unstable fractures of the distal radius. J Hand Surg 2006, 31A:359-365.
    • (2006) J Hand Surg , vol.31 A , pp. 359-365
    • Rozental, T.D.1    Blazar, P.E.2
  • 22
    • 45849144062 scopus 로고    scopus 로고
    • Prospective study of distal radius fractures treated with a volar locking plate system
    • Osada D., Kamei S., Masuzaki K., Takai M., Kameda M., Tamai K. Prospective study of distal radius fractures treated with a volar locking plate system. J Hand Surg 2008, 33A:691-700.
    • (2008) J Hand Surg , vol.33 A , pp. 691-700
    • Osada, D.1    Kamei, S.2    Masuzaki, K.3    Takai, M.4    Kameda, M.5    Tamai, K.6
  • 23
    • 47849099779 scopus 로고    scopus 로고
    • Comparative outcomes study using the volar locking plating system for distal radius fractures in both young adults and adults older than 60 years
    • Chung K.C., Squitieri L., Kim M. Comparative outcomes study using the volar locking plating system for distal radius fractures in both young adults and adults older than 60 years. J Hand Surg 2008, 33A:809-819.
    • (2008) J Hand Surg , vol.33 A , pp. 809-819
    • Chung, K.C.1    Squitieri, L.2    Kim, M.3
  • 24
    • 33845734224 scopus 로고    scopus 로고
    • Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures
    • Al-Rashid M., Theivendran K., Craigen M.A.C. Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures. J Bone Joint Surg (Br) 2006, 88B:1610-1612.
    • (2006) J Bone Joint Surg (Br) , vol.88 B , pp. 1610-1612
    • Al-Rashid, M.1    Theivendran, K.2    Craigen, M.A.C.3
  • 25
    • 34548487815 scopus 로고    scopus 로고
    • Rupture of the flexor pollicis longus tendon after volar fixed-angle plating of a distal radius fracture: a case report
    • Klug R.A., Press C.M., Gonzalez M.H. Rupture of the flexor pollicis longus tendon after volar fixed-angle plating of a distal radius fracture: a case report. J Hand Surg 2007, 32A:984-988.
    • (2007) J Hand Surg , vol.32 A , pp. 984-988
    • Klug, R.A.1    Press, C.M.2    Gonzalez, M.H.3
  • 27
    • 24944578870 scopus 로고    scopus 로고
    • Rupture de tendons fléchisseurs sur plaque antérieure après fracture du radius distal. à propos de 4cas et revue de la littérature
    • Cognet J.M., Dujardin C., Popescu A., Gouzou S., Simon P. Rupture de tendons fléchisseurs sur plaque antérieure après fracture du radius distal. à propos de 4cas et revue de la littérature. Rev Chir Orthop 2005, 91:476-481.
    • (2005) Rev Chir Orthop , vol.91 , pp. 476-481
    • Cognet, J.M.1    Dujardin, C.2    Popescu, A.3    Gouzou, S.4    Simon, P.5
  • 28
    • 39149097204 scopus 로고    scopus 로고
    • Flexor tendon injuries following locked volar plating of distal radius fractures
    • Cross A.W., Schmidt C.C. Flexor tendon injuries following locked volar plating of distal radius fractures. J Hand Surg 2008, 33A:164-167.
    • (2008) J Hand Surg , vol.33 A , pp. 164-167
    • Cross, A.W.1    Schmidt, C.C.2
  • 29
    • 37549053244 scopus 로고    scopus 로고
    • Complications of volar plating of distal radius fractures
    • Rampoldi M., Marsico S. Complications of volar plating of distal radius fractures. Acta Orthop Belg 2007, 73:714-719.
    • (2007) Acta Orthop Belg , vol.73 , pp. 714-719
    • Rampoldi, M.1    Marsico, S.2
  • 30
    • 38949184263 scopus 로고    scopus 로고
    • Inadvertent retention of angled drill guides after volar locking plate fixation of distal radial fractures. A report of three cases
    • Bhattacharyya T., Wadgaonkar A.D. Inadvertent retention of angled drill guides after volar locking plate fixation of distal radial fractures. A report of three cases. J Bone Joint Surg (Am) 2008, 90:401-403.
    • (2008) J Bone Joint Surg (Am) , vol.90 , pp. 401-403
    • Bhattacharyya, T.1    Wadgaonkar, A.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.