메뉴 건너뛰기




Volumn 44, Issue 1, 2012, Pages 51-57

Effects of an implantable two-chanel peroneal nerve stimulator versus conventional walking device on spatiote mporal para meters and kine matics of hemiparetic gait

Author keywords

Drop foot; Electrical stimulation; Gait; Peroneal nerve; Stroke

Indexed keywords

ARTICLE; BIOMECHANICS; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; FEMALE; FOOT; HUMAN; IMPLANTABLE NEUROSTIMULATOR; INNERVATION; INSTRUMENTATION; MALE; NEUROLOGIC DISEASE; PARESIS; PATHOPHYSIOLOGY; PERONEUS NERVE; PHYSIOLOGY; RANDOMIZED CONTROLLED TRIAL; TRANSCUTANEOUS NERVE STIMULATION; TREATMENT OUTCOME; VIDEORECORDING; WALKER; WALKING; WAVELET ANALYSIS;

EID: 84855870490     PISSN: 16501977     EISSN: None     Source Type: Journal    
DOI: 10.2340/16501977-0909     Document Type: Article
Times cited : (32)

References (26)
  • 1
    • 0025916953 scopus 로고
    • Importance of four variables of walking to patients with stroke
    • Importance of four variables of walking to patients with stroke. Int J Rehabil Res 1991; 14: 246-250.
    • (1991) Int J Rehabil Res , vol.14 , pp. 246-250
  • 3
    • 0036161680 scopus 로고    scopus 로고
    • Immediate and long-term effects of ankle-foot orthosis on muscle activity during walking: A randomized study of patients with unilateral foot drop
    • DOI 10.1053/apmr.2002.27462
    • Geboers JF, Drost MR, Spaans F, Kuipers H, Seelen HA. Immediate and long-term effects of ankle-foot orthosis on muscle activity during walking: A randomized study of patients with unilateral foot drop. Arch Phys Med Rehabil 2002; 83: 240-245. (Pubitemid 34121625)
    • (2002) Archives of Physical Medicine and Rehabilitation , vol.83 , Issue.2 , pp. 240-245
    • Geboers, J.F.1    Drost, M.R.2    Spaans, F.3    Kuipers, H.4    Seelen, H.A.5
  • 4
    • 73049136842 scopus 로고
    • Functional electrotherapy: Stimulation of the peroneal nerve synchronized with the swing phase of the gait of hemiplegic patients
    • Liberson WT, Holmquest HJ, Scot D, Dow M. Functional electrotherapy: Stimulation of the peroneal nerve synchronized with the swing phase of the gait of hemiplegic patients. Arch Phys Med Rehabil 1961; 42: 101-105.
    • (1961) Arch Phys Med Rehabil , vol.42 , pp. 101-105
    • Liberson, W.T.1    Holmquest, H.J.2    Scot, D.3    Dow, M.4
  • 5
    • 0037236970 scopus 로고    scopus 로고
    • Impact of ankle-foot orthosis on gait and leg muscle activity in adults with hemiplegia: Systematic literature review
    • Leung J, Mosely A. Impact of ankle-foot orthosis on gait and leg muscle activity in adults with hemiplegia: Systematic literature review. Physiotherapy 2003; 89: 39-55.
    • (2003) Physiotherapy , vol.89 , pp. 39-55
    • Leung, J.1    Mosely, A.2
  • 6
    • 0022537555 scopus 로고
    • Neurophysiological background of the use of functional electrical stimulation in paraplegia
    • Stefancic MF, Kralj A, Turk R, Bajd T, Benko H, Sega J. Neurophysiological background of the use of functional electrical stimulation in paraplegia. Electromyogr Clin Neurophysiol 1986; 26: 423-435. (Pubitemid 16050453)
    • (1986) Electromyography and Clinical Neurophysiology , vol.26 , Issue.5-6 , pp. 423-435
    • Stefancic, M.1    Kralj, A.2    Turk, R.3
  • 7
    • 57849167111 scopus 로고    scopus 로고
    • Neuroprosthesis for footdrop compared with an ankle-foot orthosis: Effects on postural control during walking
    • Ring H, Treger I, Gruendlinger L, Hausdorff JM. Neuroprosthesis for footdrop compared with an ankle-foot orthosis: Effects on postural control during walking. J Stroke Cerebrovasc Dis 2009; 18: 41-47.
    • (2009) J Stroke Cerebrovasc Dis , vol.18 , pp. 41-47
    • Ring, H.1    Treger, I.2    Gruendlinger, L.3    Hausdorff, J.M.4
  • 8
    • 79251629739 scopus 로고    scopus 로고
    • Near-normal gait pattern with peroneal electrical stimulation as a neuroprosthesis in the chronic phase of stroke: A case report
    • van Swigchem R, Weerdesteyn V, van Duijnhoven HJ, den Boer J, Beems T, Geurts AC. Near-normal gait pattern with peroneal electrical stimulation as a neuroprosthesis in the chronic phase of stroke: A case report. Arch Phys Med Rehabil 2011; 92: 320-324.
    • Arch Phys Med Rehabil , vol.2011 , Issue.92 , pp. 320-324
    • Van Swigchem, R.1    Weerdesteyn, V.2    Van Duijnhoven, H.J.3    Den Boer, J.4    Beems, T.5    Geurts, A.C.6
  • 11
    • 0036010369 scopus 로고    scopus 로고
    • Application of a dual channel peroneal nerve stimulator in a patient with a "central" drop foot
    • van der Aa HE, Bultstra G, Verloop AJ, Kenney L, Holsheimer J, Nene A, Hermens HJ, Zilvold G, Buschman HP. Application of a dual channel peroneal nerve stimulator in a patient with a "central" drop foot. Acta Neurochir Suppl 2002; 79: 105-107. (Pubitemid 33759317)
    • (2001) Acta Neurochirurgica, Supplement , vol.79 , pp. 105-107
    • Van Der Aa, H.E.1
  • 12
    • 60449086044 scopus 로고    scopus 로고
    • The reliability of three-dimensional kinematic gait measurements: A systematic review
    • McGinley JL, Baker R, Wolfe R, Morris ME. The reliability of three-dimensional kinematic gait measurements: A systematic review. Gait Posture 2009; 29: 360-369.
    • (2009) Gait Posture , vol.29 , pp. 360-369
    • McGinley, J.L.1    Baker, R.2    Wolfe, R.3    Morris, M.E.4
  • 13
    • 0001170630 scopus 로고
    • A gait analysis data collection and reduction technique
    • Davis R, Ounpuu S, Tyburski D, Gage J. A gait analysis data collection and reduction technique. Hum Movement Sci 1991; 10: 575-587.
    • (1991) Hum Movement Sci , vol.10 , pp. 575-587
    • Davis, R.1    Ounpuu, S.2    Tyburski, D.3    Gage, J.4
  • 16
    • 0025424645 scopus 로고
    • Measurement of lower extremity kinematics during level walking
    • DOI 10.1002/jor.1100080310
    • Kadaba MP, Ramakrishnan HK, Wooten ME. Lower extremity kinematics during level walking. Journal of Orthopaedic Research 1990; 8: 383-392. (Pubitemid 20250861)
    • (1990) Journal of Orthopaedic Research , vol.8 , Issue.3 , pp. 383-392
    • Kadaba, M.P.1    Ramakrishnan, H.K.2    Wootten, M.E.3
  • 17
    • 67649130025 scopus 로고    scopus 로고
    • Reliability of lower limb kinematics, mechanics and energetics during gait in patients after stroke
    • Caty GD , Detrembleur C, Bleyenheuft C, Lejeune TM. Reliability of lower limb kinematics, mechanics and energetics during gait in patients after stroke. J Rehabil Med 2009; 41; 588-590.
    • (2009) J Rehabil Med , vol.41 , pp. 588-590
    • Caty, G.D.1    Detrembleur, C.2    Bleyenheuft, C.3    Lejeune, T.M.4
  • 18
    • 41449114599 scopus 로고    scopus 로고
    • Therapeutic effect of an implantable peroneal nerve stimulator in subjects with chronic stroke and footdrop: A randomized controlled trial
    • DOI 10.2522/ptj.20070035
    • Kottink AI, Hermens HJ, Nene AV, Tenniglo MJ, Groothuis- Oudshoorn CG, Ijzerman MJ. Therapeutic effect of an implantable peroneal nerve stimulator in subjects with chronic stroke and footdrop: A randomized controlled trial. Phys Ther 2008; 88: 437-448. (Pubitemid 351458276)
    • (2008) Physical Therapy , vol.88 , Issue.4 , pp. 437-448
    • Kottink, A.I.R.1    Hermens, H.J.2    Nene, A.V.3    Tenniglo, M.J.4    Groothuis-Oudshoorn, C.G.5    Ijzerman, M.J.6
  • 19
    • 2542458248 scopus 로고    scopus 로고
    • The orthotic effect of functional electrical stimulation on the improvement of walking in stroke patients with a dropped foot: A systematic review
    • DOI 10.1111/j.1525-1594.2004.07310.x
    • Kottink AI, Oostendorp LJ, Buurke JH, Nene AV, Hermens HJ, Ijzerman MJ. The orthotic effect of functional electrical stimulation on the improvement of walking in stroke patients with a dropped foot: A systematic review. Artif Organs 2004; 28: 577-586. (Pubitemid 38692269)
    • (2004) Artificial Organs , vol.28 , Issue.6 , pp. 577-586
    • Kottink, A.I.R.1    Oostendorp, L.J.M.2    Buurke, J.H.3    Nene, A.V.4    Hermens, H.J.5    Ijzerman, M.J.6
  • 22
    • 5344229346 scopus 로고    scopus 로고
    • Effects of a simple functional electric system and/or a hinged ankle-foot orthosis on walking in persons with incomplete spinal cord injury
    • DOI 10.1016/j.apmr.2004.02.015, PII S0003999304003120
    • Kim CM, Eng JJ, Whittaker MW. Effects of a simple functional electric system and/or a hinged ankle-foot orthosis on walking in persons with incomplete spinal cord injury. Arch Phys Med Rehabil 2004; 85: 1718-1723. (Pubitemid 39349421)
    • (2004) Archives of Physical Medicine and Rehabilitation , vol.85 , Issue.10 , pp. 1718-1723
    • Kim, C.M.1    Eng, J.J.2    Whittaker, M.W.3
  • 23
    • 0033832196 scopus 로고    scopus 로고
    • Functional electrical stimulation-assisted walking for persons with incomplete spinal injuries: Changes in the kinematics and physiological cost of overground walking
    • Ladouceur M, Barbeau H. Functional electrical stimulation-assisted walking for persons with incomplete spinal injuries: Changes in the kinematics and physiological cost of overground walking. Scand J Rehabil Med 2000; 32: 72-79.
    • (2000) Scand J Rehabil Med , vol.32 , pp. 72-79
    • Ladouceur, M.1    Barbeau, H.2
  • 24
    • 67649538221 scopus 로고    scopus 로고
    • Spatiotemporal and kinematic effect of peroneal nerve stimulation vs an ankle-foot orthosis in patients with multiple sclerosis: A case series
    • Sheffler LR, Bailey SN, Chae J. Spatiotemporal and kinematic effect of peroneal nerve stimulation vs an ankle-foot orthosis in patients with multiple sclerosis: A case series. PMR 2009; 1: 604-611.
    • (2009) PMR , vol.1 , pp. 604-611
    • Sheffler, L.R.1    Bailey, S.N.2    Chae, J.3
  • 25
    • 60349122945 scopus 로고    scopus 로고
    • Neuroprosthetic effect of peroneal nerve stimulation in multiple sclerosis: A preliminary study
    • Sheffler LR, Hennessey MT, Knutson JS, Chae J. Neuroprosthetic effect of peroneal nerve stimulation in multiple sclerosis: A preliminary study. Arch Phys Med Rehabil 2009; 90: 362-365.
    • (2009) Arch Phys Med Rehabil , vol.90 , pp. 362-365
    • Sheffler, L.R.1    Hennessey, M.T.2    Knutson, J.S.3    Chae, J.4
  • 26
    • 21644453911 scopus 로고    scopus 로고
    • Gait deviations associated with post-stroke hemiparesis: Improvement during treadmill walking using weight support, speed, support stiffness, and handrail hold
    • DOI 10.1016/j.gaitpost.2004.06.008, PII S096663620400116X
    • Chen G, Patten C, Kothari DH, Zajac FE. Gait deviations associated with post-stroke hemiparesis: Improvement during treadmill walking using weight support, speed, support stiffness, and handrail hold. Gait Posture 2005; 22: 57-62. (Pubitemid 40933707)
    • (2005) Gait and Posture , vol.22 , Issue.1 , pp. 57-62
    • Chen, G.1    Patten, C.2    Kothari, D.H.3    Zajac, F.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.