메뉴 건너뛰기




Volumn 82, Issue 2, 2012, Pages

A beam-specific planning target volume (PTV) design for proton therapy to account for setup and range uncertainties

Author keywords

Proton therapy; PTV; Range uncertainties; Setup errors; Treatment planning

Indexed keywords

PROTON THERAPY; PTV; RANGE UNCERTAINTY; SETUP ERRORS; TREATMENT PLANNING;

EID: 84855861278     PISSN: 03603016     EISSN: 1879355X     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2011.05.011     Document Type: Article
Times cited : (150)

References (23)
  • 4
    • 0033041247 scopus 로고    scopus 로고
    • Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability
    • J.C. Stroom, H.C.J. De Boer, and H. Huizenga Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability Int J Radiat Oncol Biol Phys 43 1999 905 919
    • (1999) Int J Radiat Oncol Biol Phys , vol.43 , pp. 905-919
    • Stroom, J.C.1    De Boer, H.C.J.2    Huizenga, H.3
  • 5
    • 0034237797 scopus 로고    scopus 로고
    • The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy
    • M. Van Herk, P. Remeijer, and C. Rasch The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy Int J Radiat Oncol Biol Phys 47 2000 1121 1135
    • (2000) Int J Radiat Oncol Biol Phys , vol.47 , pp. 1121-1135
    • Van Herk, M.1    Remeijer, P.2    Rasch, C.3
  • 6
    • 0036800554 scopus 로고    scopus 로고
    • The effect of set-up uncertainties, contour changes, and tissue inhomogeneities on target dose-volume histograms
    • B.C.J. Cho, M. Van Herk, and B.J. Mijnheer The effect of set-up uncertainties, contour changes, and tissue inhomogeneities on target dose-volume histograms Med Phys 29 2002 2305 2318
    • (2002) Med Phys , vol.29 , pp. 2305-2318
    • Cho, B.C.J.1    Van Herk, M.2    Mijnheer, B.J.3
  • 7
    • 0035312569 scopus 로고    scopus 로고
    • Methodologies and tools for proton beam design for lung tumors
    • M.F. Moyers, D.W. Miller, and D.A. Bush Methodologies and tools for proton beam design for lung tumors Int J Radiat Oncol Biol Phys 49 2001 1429 1438
    • (2001) Int J Radiat Oncol Biol Phys , vol.49 , pp. 1429-1438
    • Moyers, M.F.1    Miller, D.W.2    Bush, D.A.3
  • 8
    • 33645005637 scopus 로고    scopus 로고
    • Target volume dose considerations in proton beam treatment planning for lung tumors
    • M. Engelsman, and H.M. Kooy Target volume dose considerations in proton beam treatment planning for lung tumors Med Phys 32 2005 3549 3557
    • (2005) Med Phys , vol.32 , pp. 3549-3557
    • Engelsman, M.1    Kooy, H.M.2
  • 9
    • 39049126842 scopus 로고    scopus 로고
    • Intensity modulated proton therapy and its sensitivity to treatment uncertainties 2: The potential effects of inter-fraction and inter-field motions
    • A.J. Lomax Intensity modulated proton therapy and its sensitivity to treatment uncertainties 2: The potential effects of inter-fraction and inter-field motions Phys Med Biol 53 2008 1043 1056
    • (2008) Phys Med Biol , vol.53 , pp. 1043-1056
    • Lomax, A.J.1
  • 10
    • 39049164210 scopus 로고    scopus 로고
    • Intensity modulated proton therapy and its sensitivity to treatment uncertainties 1: The potential effects of calculational uncertainties
    • A.J. Lomax Intensity modulated proton therapy and its sensitivity to treatment uncertainties 1: The potential effects of calculational uncertainties Phys Med Biol 53 2008 1027 1042
    • (2008) Phys Med Biol , vol.53 , pp. 1027-1042
    • Lomax, A.J.1
  • 11
    • 79952157958 scopus 로고    scopus 로고
    • Spot scanning proton beam therapy for prostate cancer: Treatment planning technique and analysis of consequences of rotational and translational alignment errors
    • J. Meyer, J. Bluett, and R. Amos Spot scanning proton beam therapy for prostate cancer: Treatment planning technique and analysis of consequences of rotational and translational alignment errors Int J Radiat Oncol Biol Phys 78 2010 428 434
    • (2010) Int J Radiat Oncol Biol Phys , vol.78 , pp. 428-434
    • Meyer, J.1    Bluett, J.2    Amos, R.3
  • 12
    • 67651236738 scopus 로고    scopus 로고
    • Characteristics of movement-induced dose reduction in target volume: A comparison between photon and proton beam treatment
    • M. Yoon, D. Shin, and J. Kwak Characteristics of movement-induced dose reduction in target volume: A comparison between photon and proton beam treatment Med Dosim 34 2009 191 201
    • (2009) Med Dosim , vol.34 , pp. 191-201
    • Yoon, M.1    Shin, D.2    Kwak, J.3
  • 13
    • 34548492287 scopus 로고    scopus 로고
    • Radiotherapy treatment of early-stage prostate cancer with IMRT and protons: A treatment planning comparison
    • A. Trofimov, P.L. Nguyen, and J.J. Coen Radiotherapy treatment of early-stage prostate cancer with IMRT and protons: A treatment planning comparison Int J Radiat Oncol Biol Phys 69 2007 444 453
    • (2007) Int J Radiat Oncol Biol Phys , vol.69 , pp. 444-453
    • Trofimov, A.1    Nguyen, P.L.2    Coen, J.J.3
  • 14
    • 51449090189 scopus 로고    scopus 로고
    • Intensity-modulated proton therapy versus helical tomotherapy in nasopharynx cancer: Planning comparison and NTCP evaluation
    • L. Widesott, A. Pierelli, and C. Fiorino Intensity-modulated proton therapy versus helical tomotherapy in nasopharynx cancer: Planning comparison and NTCP evaluation Int J Radiat Oncol Biol Phys 72 2008 589 596
    • (2008) Int J Radiat Oncol Biol Phys , vol.72 , pp. 589-596
    • Widesott, L.1    Pierelli, A.2    Fiorino, C.3
  • 15
    • 49549094738 scopus 로고    scopus 로고
    • Four-dimensional computed tomography-based treatment planning for intensity-modulated radiation therapy and proton therapy for distal esophageal cancer
    • X. Zhang, K.- Zhao, and T.M. Guerrero Four-dimensional computed tomography-based treatment planning for intensity-modulated radiation therapy and proton therapy for distal esophageal cancer Int J Radiat Oncol Biol Phys 72 2008 278 287
    • (2008) Int J Radiat Oncol Biol Phys , vol.72 , pp. 278-287
    • Zhang, X.1    Zhao, K.2    Guerrero, T.M.3
  • 16
    • 75749129109 scopus 로고    scopus 로고
    • Respiratory motion management in particle therapy
    • E. Rietzel, and C. Bert Respiratory motion management in particle therapy Med Phys 37 2010 449 460
    • (2010) Med Phys , vol.37 , pp. 449-460
    • Rietzel, E.1    Bert, C.2
  • 17
    • 0021134641 scopus 로고
    • Compensating for heterogeneities in proton radiation therapy
    • M. Urie, M. Goitein, and M. Wagner Compensating for heterogeneities in proton radiation therapy Plasma Sources Sci Technol 29 1984 553 566
    • (1984) Plasma Sources Sci Technol , vol.29 , pp. 553-566
    • Urie, M.1    Goitein, M.2    Wagner, M.3
  • 18
    • 0031807135 scopus 로고    scopus 로고
    • The precision of proton range calculations in proton radiotherapy treatment planning: Experimental verification of the relation between CT-HU and proton stopping power
    • B. Schaffner, and E. Pedroni The precision of proton range calculations in proton radiotherapy treatment planning: Experimental verification of the relation between CT-HU and proton stopping power Phys Med Biol 43 1998 1579 1592
    • (1998) Phys Med Biol , vol.43 , pp. 1579-1592
    • Schaffner, B.1    Pedroni, E.2
  • 19
    • 33645960383 scopus 로고    scopus 로고
    • Calculation of stopping power ratios for carbon ion dosimetry
    • O. Geithner, P. Andreo, and N. Sobolevsky Calculation of stopping power ratios for carbon ion dosimetry Phys Med Biol 51 2006 2279 2292
    • (2006) Phys Med Biol , vol.51 , pp. 2279-2292
    • Geithner, O.1    Andreo, P.2    Sobolevsky, N.3
  • 20
    • 77955246260 scopus 로고    scopus 로고
    • Ion stopping powers and CT numbers
    • M.F. Moyers, M. Sardesai, and S. Sun Ion stopping powers and CT numbers Med Dosim 35 2010 179 194
    • (2010) Med Dosim , vol.35 , pp. 179-194
    • Moyers, M.F.1    Sardesai, M.2    Sun, S.3
  • 21
    • 0030065290 scopus 로고    scopus 로고
    • The calibration of CT Hounsfield units for radiotherapy treatment planning
    • U. Schneider, E. Pedroni, and A. Lomax The calibration of CT Hounsfield units for radiotherapy treatment planning Phys Med Biol 41 1996 111 124
    • (1996) Phys Med Biol , vol.41 , pp. 111-124
    • Schneider, U.1    Pedroni, E.2    Lomax, A.3
  • 22
    • 45449087065 scopus 로고    scopus 로고
    • Inter- and intrafractional movement-induced dose reduction of prostate target volume in proton beam treatment
    • M. Yoon, D. Kim, and D.H. Shin Inter- and intrafractional movement-induced dose reduction of prostate target volume in proton beam treatment Int J Radiat Oncol Biol Phys 71 2008 1091 1102
    • (2008) Int J Radiat Oncol Biol Phys , vol.71 , pp. 1091-1102
    • Yoon, M.1    Kim, D.2    Shin, D.H.3
  • 23
    • 0032949514 scopus 로고    scopus 로고
    • Intensity modulation methods for proton radiotherapy
    • A. Lomax Intensity modulation methods for proton radiotherapy Phys Med Biol 44 1999 185 205
    • (1999) Phys Med Biol , vol.44 , pp. 185-205
    • Lomax, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.