메뉴 건너뛰기




Volumn 28, Issue 2, 2012, Pages 188-195

Optimizing pressurized contact area in rotator cuff repair: The diamondback repair

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CADAVER; HUMAN; HUMAN TISSUE; INTERMETHOD COMPARISON; PRESSURE MEASUREMENT; ROTATOR CUFF RUPTURE; SURGICAL TECHNIQUE; WEIGHT BEARING;

EID: 84855840301     PISSN: 07498063     EISSN: 15263231     Source Type: Journal    
DOI: 10.1016/j.arthro.2011.07.021     Document Type: Article
Times cited : (30)

References (23)
  • 2
    • 67650327271 scopus 로고    scopus 로고
    • A prospective randomized clinical trial comparing arthroscopic single- and double-row rotator cuff repair: Magnetic resonance imaging and early clinical evaluation
    • R.T. Burks, J. Crim, N. Brown, B. Fink, P.E. Greis A prospective randomized clinical trial comparing arthroscopic single- and double-row rotator cuff repair: Magnetic resonance imaging and early clinical evaluation Am J Sports Med 37 2009 674 682
    • (2009) Am J Sports Med , vol.37 , pp. 674-682
    • Burks, R.T.1    Crim, J.2    Brown, N.3    Fink, B.4    Greis, P.E.5
  • 3
    • 77954695636 scopus 로고    scopus 로고
    • Which method of rotator cuff repair leads to the highest rate of structural healing? A systematic review
    • T.R. Duquin, C. Buyea, L.J. Bisson Which method of rotator cuff repair leads to the highest rate of structural healing? A systematic review Am J Sports Med 38 2010 835 841
    • (2010) Am J Sports Med , vol.38 , pp. 835-841
    • Duquin, T.R.1    Buyea, C.2    Bisson, L.J.3
  • 6
    • 34447568149 scopus 로고    scopus 로고
    • Part I: Footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique
    • DOI 10.1016/j.jse.2006.09.010, PII S1058274606003168
    • M.C. Park, N.S. ElAttrache, J.E. Tibone, C.S. Ahmad, B.J. Jun, T.Q. Lee Part I: Footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique J Shoulder Elbow Surg 16 2007 461 468 (Pubitemid 47081400)
    • (2007) Journal of Shoulder and Elbow Surgery , vol.16 , Issue.4 , pp. 461-468
    • Park, M.C.1    ElAttrache, N.S.2    Tibone, J.E.3    Ahmad, C.S.4    Jun, B.-J.5    Lee, T.Q.6
  • 7
    • 34250661991 scopus 로고    scopus 로고
    • Part II: Biomechanical assessment for a footprint-restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique
    • DOI 10.1016/j.jse.2006.09.011, PII S105827460600317X
    • M.C. Park, J.E. Tibone, N.S. ElAttrache, C.S. Ahmad, B.J. Jun, T.Q. Lee Part II: Biomechanical assessment for a footprint-restoring transosseous- equivalent rotator cuff repair technique compared with a double-row repair technique J Shoulder Elbow Surg 16 2007 469 476 (Pubitemid 47081401)
    • (2007) Journal of Shoulder and Elbow Surgery , vol.16 , Issue.4 , pp. 469-476
    • Park, M.C.1    Tibone, J.E.2    ElAttrache, N.S.3    Ahmad, C.S.4    Jun, B.-J.5    Lee, T.Q.6
  • 8
    • 27544450312 scopus 로고    scopus 로고
    • Tendon-bone interface motion in transosseous suture and suture anchor rotator cuff repair techniques
    • DOI 10.1177/0363546505278252
    • C.S. Ahmad, A.M. Stewart, R. Izquierdo, L.U. Bigliani Tendon-bone interface motion in transosseous suture and suture anchor rotator cuff repair techniques Am J Sports Med 33 2005 1667 1671 (Pubitemid 41546740)
    • (2005) American Journal of Sports Medicine , vol.33 , Issue.11 , pp. 1667-1671
    • Ahmad, C.S.1    Stewart, A.M.2    Izquierdo, R.3    Bigliani, L.U.4
  • 9
    • 22944438054 scopus 로고    scopus 로고
    • Tendon-to-bone pressure distributions at a repaired rotator cuff footprint using transosseous suture and suture anchor fixation techniques
    • DOI 10.1177/0363546504273053
    • M.C. Park, E.R. Cadet, W.N. Levine, L.U. Bigliani, C.S. Ahmad Tendon-to-bone pressure distributions at a repaired rotator cuff footprint using transosseous suture and suture anchor fixation techniques Am J Sports Med 33 2005 1154 1159 (Pubitemid 41045187)
    • (2005) American Journal of Sports Medicine , vol.33 , Issue.8 , pp. 1154-1159
    • Park, M.C.1    Cadet, E.R.2    Levine, W.N.3    Bigliani, L.U.4    Ahmad, C.S.5
  • 10
    • 33646024967 scopus 로고    scopus 로고
    • Measuring contact area, force, and pressure for bioengineering applications: Using Fuji Film and TekScan systems
    • K.N. Bachus, A.L. DeMarco, K.T. Judd, D.S. Horwitz, D.S. Brodke Measuring contact area, force, and pressure for bioengineering applications: Using Fuji Film and TekScan systems Med Eng Phys 28 2006 483 488
    • (2006) Med Eng Phys , vol.28 , pp. 483-488
    • Bachus, K.N.1    Demarco, A.L.2    Judd, K.T.3    Horwitz, D.S.4    Brodke, D.S.5
  • 12
    • 18844366602 scopus 로고    scopus 로고
    • Biomechanical evaluation after five and ten millimeter anterior glenohumeral capsulorrhaphy using a novel shoulder model of increased laxity
    • DOI 10.1016/j.jse.2004.07.006, PII S1058274604002381
    • D.J. Schneider, J.E. Tibone, M.H. McGarry, M.G. Grossman, S. Veneziani, T.Q. Lee Biomechanical evaluation after five and ten millimeter anterior glenohumeral capsulorrhaphy using a novel shoulder model of increased laxity J Shoulder Elbow Surg 14 2005 318 323 (Pubitemid 40693783)
    • (2005) Journal of Shoulder and Elbow Surgery , vol.14 , Issue.3 , pp. 318-323
    • Schneider, D.J.1    Tibone, J.E.2    McGarry, M.H.3    Grossman, M.G.4    Veneziani, S.5    Lee, T.Q.6
  • 14
    • 0036590568 scopus 로고    scopus 로고
    • Rotator cuff tears: The effect of the reconstruction method on three-dimensional repair site area
    • DOI 10.1053/jars.2002.32930
    • M. Apreleva, M. Ozbaydar, P.G. Fitzgibbons, J.J. Warner Rotator cuff tears: The effect of the reconstruction method on three-dimensional repair site area Arthroscopy 18 2002 519 526 (Pubitemid 36114564)
    • (2002) Arthroscopy , vol.18 , Issue.5 , pp. 519-526
    • Apreleva, M.1    Ozbaydar, M.2    Fitzgibbons, P.G.3    Warner, J.J.P.4
  • 16
    • 77951291536 scopus 로고    scopus 로고
    • Biomechanical evaluation of arthroscopic rotator cuff repairs over time
    • A.D. Mazzocca, M.J. Bollier, A.M. Ciminiello Biomechanical evaluation of arthroscopic rotator cuff repairs over time Arthroscopy 26 2010 592 599
    • (2010) Arthroscopy , vol.26 , pp. 592-599
    • Mazzocca, A.D.1    Bollier, M.J.2    Ciminiello, A.M.3
  • 18
    • 0028954390 scopus 로고
    • The deadman theory of suture anchors: Observations along a South Texas fence line
    • S.S. Burkhart The deadman theory of suture anchors: Observations along a South Texas fence line Arthroscopy 11 1995 119 123
    • (1995) Arthroscopy , vol.11 , pp. 119-123
    • Burkhart, S.S.1
  • 19
    • 60549090404 scopus 로고    scopus 로고
    • A biomechanical comparison of 2 techniques of footprint reconstruction for rotator cuff repair: The SwiveLock-FiberChain construct versus standard double-row repair
    • S.S. Burkhart, C.R. Adams, S.S. Burkhart, J.D. Schoolfield A biomechanical comparison of 2 techniques of footprint reconstruction for rotator cuff repair: The SwiveLock-FiberChain construct versus standard double-row repair Arthroscopy 25 2009 274 281
    • (2009) Arthroscopy , vol.25 , pp. 274-281
    • Burkhart, S.S.1    Adams, C.R.2    Burkhart, S.S.3    Schoolfield, J.D.4
  • 20
    • 1242321337 scopus 로고    scopus 로고
    • Transtendon arthroscopic repair of partial-thickness, articular surface tears of the Rotator Cuff
    • DOI 10.1016/j.arthro.2003.11.042
    • I.K. Lo, S.S. Burkhart Transtendon arthroscopic repair of partial-thickness, articular surface tears of the rotator cuff Arthroscopy 20 2004 214 220 (Pubitemid 38233689)
    • (2004) Arthroscopy - Journal of Arthroscopic and Related Surgery , vol.20 , Issue.2 , pp. 214-220
    • Lo, I.K.Y.1    Burkhart, S.S.2
  • 21
    • 34249877953 scopus 로고    scopus 로고
    • The double-pulley technique for double-row rotator cuff repair
    • P. Arrigoni, P.C. Brady, S.S. Burkhart The double-pulley technique for double-row rotator cuff repair Arthroscopy 23 2007 675.e1 675.e4 www.arthroscopyjournal.org
    • (2007) Arthroscopy , vol.23
    • Arrigoni, P.1    Brady, P.C.2    Burkhart, S.S.3
  • 23
    • 71649096574 scopus 로고    scopus 로고
    • Vascularity of the supraspinatus tendon three months after repair: Characterization using contrast-enhanced ultrasound
    • S.C. Gamradt, R.A. Gallo, R.S. Adler Vascularity of the supraspinatus tendon three months after repair: Characterization using contrast-enhanced ultrasound J Shoulder Elbow Surg 19 2010 73 80
    • (2010) J Shoulder Elbow Surg , vol.19 , pp. 73-80
    • Gamradt, S.C.1    Gallo, R.A.2    Adler, R.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.