-
1
-
-
34447560059
-
Equivalent clinical results of arthroscopic single-row and double-row suture anchor repair for rotator cuff tears: A randomized controlled trial
-
DOI 10.1177/0363546507302218
-
F. Franceschi, L. Ruzzini, U.G. Longo Equivalent clinical results of arthroscopic single-row and double-row suture anchor repair for rotator cuff tears: A randomized controlled trial Am J Sports Med 35 2007 1254 1260 (Pubitemid 47084206)
-
(2007)
American Journal of Sports Medicine
, vol.35
, Issue.8
, pp. 1254-1260
-
-
Franceschi, F.1
Ruzzini, L.2
Longo, U.G.3
Martina, F.M.4
Beomonte Zobel, B.5
Maffulli, N.6
Denaro, V.7
-
2
-
-
67650327271
-
A prospective randomized clinical trial comparing arthroscopic single- and double-row rotator cuff repair: Magnetic resonance imaging and early clinical evaluation
-
R.T. Burks, J. Crim, N. Brown, B. Fink, P.E. Greis A prospective randomized clinical trial comparing arthroscopic single- and double-row rotator cuff repair: Magnetic resonance imaging and early clinical evaluation Am J Sports Med 37 2009 674 682
-
(2009)
Am J Sports Med
, vol.37
, pp. 674-682
-
-
Burks, R.T.1
Crim, J.2
Brown, N.3
Fink, B.4
Greis, P.E.5
-
3
-
-
77954695636
-
Which method of rotator cuff repair leads to the highest rate of structural healing? A systematic review
-
T.R. Duquin, C. Buyea, L.J. Bisson Which method of rotator cuff repair leads to the highest rate of structural healing? A systematic review Am J Sports Med 38 2010 835 841
-
(2010)
Am J Sports Med
, vol.38
, pp. 835-841
-
-
Duquin, T.R.1
Buyea, C.2
Bisson, L.J.3
-
4
-
-
28344447544
-
Arthroscopic single-row versus double-row suture anchor rotator cuff repair
-
A.D. Mazzocca, P.J. Millett, C.A. Guanche, S.A. Santangelo, R.A. Arciero Arthroscopic single-row versus double-row suture anchor rotator cuff repair Am J Sports Med 33 2005 1861 1968
-
(2005)
Am J Sports Med
, vol.33
, pp. 1861-1968
-
-
Mazzocca, A.D.1
Millett, P.J.2
Guanche, C.A.3
Santangelo, S.A.4
Arciero, R.A.5
-
5
-
-
28344449190
-
Contact area, contact pressure, and pressure patterns of the tendon-bone interface after rotator cuff repair
-
DOI 10.1177/0363546505278256
-
Y. Tuoheti, E. Itoi, N. Yamamoto Contact area, contact pressure and pressure patterns of the tendon-bone interface after rotator cuff repair Am J Sports Med 22 2005 1869 1874 (Pubitemid 41720587)
-
(2005)
American Journal of Sports Medicine
, vol.33
, Issue.12
, pp. 1869-1874
-
-
Tuoheti, Y.1
Itoi, E.2
Yamamoto, N.3
Seki, N.4
Abe, H.5
Minagawa, H.6
Okada, K.7
Shimada, Y.8
-
6
-
-
34447568149
-
Part I: Footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique
-
DOI 10.1016/j.jse.2006.09.010, PII S1058274606003168
-
M.C. Park, N.S. ElAttrache, J.E. Tibone, C.S. Ahmad, B.J. Jun, T.Q. Lee Part I: Footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique J Shoulder Elbow Surg 16 2007 461 468 (Pubitemid 47081400)
-
(2007)
Journal of Shoulder and Elbow Surgery
, vol.16
, Issue.4
, pp. 461-468
-
-
Park, M.C.1
ElAttrache, N.S.2
Tibone, J.E.3
Ahmad, C.S.4
Jun, B.-J.5
Lee, T.Q.6
-
7
-
-
34250661991
-
Part II: Biomechanical assessment for a footprint-restoring transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique
-
DOI 10.1016/j.jse.2006.09.011, PII S105827460600317X
-
M.C. Park, J.E. Tibone, N.S. ElAttrache, C.S. Ahmad, B.J. Jun, T.Q. Lee Part II: Biomechanical assessment for a footprint-restoring transosseous- equivalent rotator cuff repair technique compared with a double-row repair technique J Shoulder Elbow Surg 16 2007 469 476 (Pubitemid 47081401)
-
(2007)
Journal of Shoulder and Elbow Surgery
, vol.16
, Issue.4
, pp. 469-476
-
-
Park, M.C.1
Tibone, J.E.2
ElAttrache, N.S.3
Ahmad, C.S.4
Jun, B.-J.5
Lee, T.Q.6
-
8
-
-
27544450312
-
Tendon-bone interface motion in transosseous suture and suture anchor rotator cuff repair techniques
-
DOI 10.1177/0363546505278252
-
C.S. Ahmad, A.M. Stewart, R. Izquierdo, L.U. Bigliani Tendon-bone interface motion in transosseous suture and suture anchor rotator cuff repair techniques Am J Sports Med 33 2005 1667 1671 (Pubitemid 41546740)
-
(2005)
American Journal of Sports Medicine
, vol.33
, Issue.11
, pp. 1667-1671
-
-
Ahmad, C.S.1
Stewart, A.M.2
Izquierdo, R.3
Bigliani, L.U.4
-
9
-
-
22944438054
-
Tendon-to-bone pressure distributions at a repaired rotator cuff footprint using transosseous suture and suture anchor fixation techniques
-
DOI 10.1177/0363546504273053
-
M.C. Park, E.R. Cadet, W.N. Levine, L.U. Bigliani, C.S. Ahmad Tendon-to-bone pressure distributions at a repaired rotator cuff footprint using transosseous suture and suture anchor fixation techniques Am J Sports Med 33 2005 1154 1159 (Pubitemid 41045187)
-
(2005)
American Journal of Sports Medicine
, vol.33
, Issue.8
, pp. 1154-1159
-
-
Park, M.C.1
Cadet, E.R.2
Levine, W.N.3
Bigliani, L.U.4
Ahmad, C.S.5
-
10
-
-
33646024967
-
Measuring contact area, force, and pressure for bioengineering applications: Using Fuji Film and TekScan systems
-
K.N. Bachus, A.L. DeMarco, K.T. Judd, D.S. Horwitz, D.S. Brodke Measuring contact area, force, and pressure for bioengineering applications: Using Fuji Film and TekScan systems Med Eng Phys 28 2006 483 488
-
(2006)
Med Eng Phys
, vol.28
, pp. 483-488
-
-
Bachus, K.N.1
Demarco, A.L.2
Judd, K.T.3
Horwitz, D.S.4
Brodke, D.S.5
-
11
-
-
0242441672
-
Biomechanical evaluation of multidirectional glenohumeral instability and repair
-
L.F. Remia, R.V. Ravalin, K.S. Lemly, M.H. McGarry, R.S. Kvitne, T.Q. Lee Biomechanical evaluation of multidirectional glenohumeral instability and repair Clin Orthop Relat Res 416 2003 225 236 (Pubitemid 37413643)
-
(2003)
Clinical Orthopaedics and Related Research
, Issue.416
, pp. 225-236
-
-
Remia, L.F.1
Ravalin, R.V.2
Lemly, K.S.3
McGarry, M.H.4
Kvitne, R.S.5
Lee, T.Q.6
-
12
-
-
18844366602
-
Biomechanical evaluation after five and ten millimeter anterior glenohumeral capsulorrhaphy using a novel shoulder model of increased laxity
-
DOI 10.1016/j.jse.2004.07.006, PII S1058274604002381
-
D.J. Schneider, J.E. Tibone, M.H. McGarry, M.G. Grossman, S. Veneziani, T.Q. Lee Biomechanical evaluation after five and ten millimeter anterior glenohumeral capsulorrhaphy using a novel shoulder model of increased laxity J Shoulder Elbow Surg 14 2005 318 323 (Pubitemid 40693783)
-
(2005)
Journal of Shoulder and Elbow Surgery
, vol.14
, Issue.3
, pp. 318-323
-
-
Schneider, D.J.1
Tibone, J.E.2
McGarry, M.H.3
Grossman, M.G.4
Veneziani, S.5
Lee, T.Q.6
-
13
-
-
0036563405
-
Biomechanical comparison of effects of supraspinatus tendon detachments, tendon defects, and muscle retractions
-
A.M. Halder, S.W. O'Driscoll, G. Heers Biomechanical comparison of effects of supraspinatus tendon detachments, tendon defects, and muscle retractions J Bone Joint Surg Am 84 2002 780 785 (Pubitemid 34925038)
-
(2002)
Journal of Bone and Joint Surgery - Series A
, vol.84
, Issue.5
, pp. 780-785
-
-
Halder, A.M.1
O'Driscoll, S.W.2
Heers, G.3
Mura, N.4
Zobitz, M.E.5
An, K.N.6
Kreusch-Brinker, R.7
-
14
-
-
0036590568
-
Rotator cuff tears: The effect of the reconstruction method on three-dimensional repair site area
-
DOI 10.1053/jars.2002.32930
-
M. Apreleva, M. Ozbaydar, P.G. Fitzgibbons, J.J. Warner Rotator cuff tears: The effect of the reconstruction method on three-dimensional repair site area Arthroscopy 18 2002 519 526 (Pubitemid 36114564)
-
(2002)
Arthroscopy
, vol.18
, Issue.5
, pp. 519-526
-
-
Apreleva, M.1
Ozbaydar, M.2
Fitzgibbons, P.G.3
Warner, J.J.P.4
-
15
-
-
33744534489
-
The insertional footprint of the rotator cuff: An anatomic study
-
A.S. Curtis, K.M. Burbank, J.J. Tierney, A.D. Scheller, A.R. Curran The insertional footprint of the rotator cuff: An anatomic study Arthroscopy 22 2006 603 609
-
(2006)
Arthroscopy
, vol.22
, pp. 603-609
-
-
Curtis, A.S.1
Burbank, K.M.2
Tierney, J.J.3
Scheller, A.D.4
Curran, A.R.5
-
16
-
-
77951291536
-
Biomechanical evaluation of arthroscopic rotator cuff repairs over time
-
A.D. Mazzocca, M.J. Bollier, A.M. Ciminiello Biomechanical evaluation of arthroscopic rotator cuff repairs over time Arthroscopy 26 2010 592 599
-
(2010)
Arthroscopy
, vol.26
, pp. 592-599
-
-
Mazzocca, A.D.1
Bollier, M.J.2
Ciminiello, A.M.3
-
17
-
-
33745872209
-
The arthroscopic square knot: A biomechanical comparison with open and arthroscopic knots
-
DOI 10.1016/j.arthro.2006.04.075, PII S0749806306005585
-
H. Elkousy, S.M. Hammerman, T.B. Edwards The arthroscopic square knot: A biomechanical comparison with open and arthroscopic knots Arthroscopy 22 2006 736 741 (Pubitemid 44038168)
-
(2006)
Arthroscopy - Journal of Arthroscopic and Related Surgery
, vol.22
, Issue.7
, pp. 736-741
-
-
Elkousy, H.1
Hammerman, S.M.2
Edwards, T.B.3
Warnock, K.M.4
O'Connor, D.P.5
Ambrose, C.6
Meyers, D.7
Gartsman, G.M.8
-
18
-
-
0028954390
-
The deadman theory of suture anchors: Observations along a South Texas fence line
-
S.S. Burkhart The deadman theory of suture anchors: Observations along a South Texas fence line Arthroscopy 11 1995 119 123
-
(1995)
Arthroscopy
, vol.11
, pp. 119-123
-
-
Burkhart, S.S.1
-
19
-
-
60549090404
-
A biomechanical comparison of 2 techniques of footprint reconstruction for rotator cuff repair: The SwiveLock-FiberChain construct versus standard double-row repair
-
S.S. Burkhart, C.R. Adams, S.S. Burkhart, J.D. Schoolfield A biomechanical comparison of 2 techniques of footprint reconstruction for rotator cuff repair: The SwiveLock-FiberChain construct versus standard double-row repair Arthroscopy 25 2009 274 281
-
(2009)
Arthroscopy
, vol.25
, pp. 274-281
-
-
Burkhart, S.S.1
Adams, C.R.2
Burkhart, S.S.3
Schoolfield, J.D.4
-
20
-
-
1242321337
-
Transtendon arthroscopic repair of partial-thickness, articular surface tears of the Rotator Cuff
-
DOI 10.1016/j.arthro.2003.11.042
-
I.K. Lo, S.S. Burkhart Transtendon arthroscopic repair of partial-thickness, articular surface tears of the rotator cuff Arthroscopy 20 2004 214 220 (Pubitemid 38233689)
-
(2004)
Arthroscopy - Journal of Arthroscopic and Related Surgery
, vol.20
, Issue.2
, pp. 214-220
-
-
Lo, I.K.Y.1
Burkhart, S.S.2
-
21
-
-
34249877953
-
The double-pulley technique for double-row rotator cuff repair
-
P. Arrigoni, P.C. Brady, S.S. Burkhart The double-pulley technique for double-row rotator cuff repair Arthroscopy 23 2007 675.e1 675.e4 www.arthroscopyjournal.org
-
(2007)
Arthroscopy
, vol.23
-
-
Arrigoni, P.1
Brady, P.C.2
Burkhart, S.S.3
-
22
-
-
29844432435
-
Patterns of vascular and anatomical response after rotator cuff repair
-
DOI 10.1177/0363546505280212
-
S. Fealy, R.S. Adler, M.C. Drakos Patterns of vascular and anatomical response after rotator cuff repair Am J Sports Med 34 2006 120 127 (Pubitemid 43038238)
-
(2006)
American Journal of Sports Medicine
, vol.34
, Issue.1
, pp. 120-127
-
-
Fealy, S.1
Adler, R.S.2
Drakos, M.C.3
Kelly, A.M.4
Allen, A.A.5
Cordasco, F.A.6
Warren, R.F.7
O'Brien, S.J.8
-
23
-
-
71649096574
-
Vascularity of the supraspinatus tendon three months after repair: Characterization using contrast-enhanced ultrasound
-
S.C. Gamradt, R.A. Gallo, R.S. Adler Vascularity of the supraspinatus tendon three months after repair: Characterization using contrast-enhanced ultrasound J Shoulder Elbow Surg 19 2010 73 80
-
(2010)
J Shoulder Elbow Surg
, vol.19
, pp. 73-80
-
-
Gamradt, S.C.1
Gallo, R.A.2
Adler, R.S.3
|