메뉴 건너뛰기




Volumn 31, Issue 2, 2012, Pages 172-175

Outcomes of descemet stripping automated endothelial keratoplasty in patients with previous glaucoma drainage device insertion

Author keywords

Descemet stripping automated endothelial keratoplasty; DSAEK; endothelial keratoplasty; glaucoma; glaucoma drainage device

Indexed keywords

ANTIGLAUCOMA AGENT;

EID: 84855839548     PISSN: 02773740     EISSN: 15364798     Source Type: Journal    
DOI: 10.1097/ICO.0b013e318224820a     Document Type: Article
Times cited : (52)

References (31)
  • 2
    • 69249208489 scopus 로고    scopus 로고
    • Descemet's stripping endothelial keratoplasty: Safety and outcomes: A report by the American Academy of Ophthalmology
    • Lee WB, Jacobs DS, Musch DC, et al. Descemet's stripping endothelial keratoplasty: safety and outcomes: a report by the American Academy of Ophthalmology. Ophthalmology. 2009;116:1818-1830.
    • (2009) Ophthalmology , vol.116 , pp. 1818-1830
    • Lee, W.B.1    Jacobs, D.S.2    Musch, D.C.3
  • 3
    • 33750289861 scopus 로고    scopus 로고
    • Descemet's Stripping with Endothelial Keratoplasty. Comparative Outcomes with Microkeratome-Dissected and Manually Dissected Donor Tissue
    • DOI 10.1016/j.ophtha.2006.05.034, PII S0161642006007202
    • Price MO, Price FW Jr. Descemet's stripping with endothelial keratoplasty: comparative outcomes with microkeratome-dissected and manually dissected donor tissue. Ophthalmology. 2006;113:1936-1942. (Pubitemid 44635703)
    • (2006) Ophthalmology , vol.113 , Issue.11 , pp. 1936-1942
    • Price, M.O.1    Price Jr., F.W.2
  • 4
    • 50249105211 scopus 로고    scopus 로고
    • Complications of Descemet's stripping with automated endothelial keratoplasty: Survey of 118 eyes at One Institute
    • Suh LH, Yoo SH, Deobhakta A, et al. Complications of Descemet's stripping with automated endothelial keratoplasty: survey of 118 eyes at One Institute. Ophthalmology. 2008;115:1517-1524.
    • (2008) Ophthalmology , vol.115 , pp. 1517-1524
    • Suh, L.H.1    Yoo, S.H.2    Deobhakta, A.3
  • 5
    • 33646036099 scopus 로고    scopus 로고
    • Descemet's stripping with endothelial keratoplasty in 200 eyes: Early challenges and techniques to enhance donor adherence
    • Price FW Jr, Price MO. Descemet's stripping with endothelial keratoplasty in 200 eyes: early challenges and techniques to enhance donor adherence. J Cataract Refract Surg. 2006;32:411-418.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 411-418
    • Price, Jr.F.W.1    Price, M.O.2
  • 6
    • 62849124782 scopus 로고    scopus 로고
    • Corneal complications of glaucoma surgery
    • Hau S, Barton K. Corneal complications of glaucoma surgery. Curr Opin Ophthalmol. 2009;20:131-136.
    • (2009) Curr Opin Ophthalmol , vol.20 , pp. 131-136
    • Hau, S.1    Barton, K.2
  • 9
    • 0029009552 scopus 로고
    • Effect of mitomycin C and fluorouracil-supplemented trabeculectomies on the anterior segment
    • Dreyer EB, Chaturvedi N, Zurakowski D. Effect of mitomycin C and fluorouracil-supplemented trabeculectomies on the anterior segment. Arch Ophthalmol. 1995;113:578-580.
    • (1995) Arch Ophthalmol , vol.113 , pp. 578-580
    • Dreyer, E.B.1    Chaturvedi, N.2    Zurakowski, D.3
  • 11
    • 33845487133 scopus 로고    scopus 로고
    • Surgical complications in the tube versus trabeculectomy study during the first year of follow-up
    • Gedde SJ, Herndon LW, Brandt JD, et al. Surgical complications in the tube versus trabeculectomy study during the first year of follow-up. Am J Ophthalmol. 2007;143:23-31.
    • (2007) Am J Ophthalmol , vol.143 , pp. 23-31
    • Gedde, S.J.1    Herndon, L.W.2    Brandt, J.D.3
  • 13
    • 77951768968 scopus 로고    scopus 로고
    • Descemet stripping automated endothelial keratoplasty in eyes with previous trabeculectomy and tube shunt procedures: Intraoperative and early postoperative complications
    • Phillips PM, Terry MA, Shamie N, et al. Descemet stripping automated endothelial keratoplasty in eyes with previous trabeculectomy and tube shunt procedures: intraoperative and early postoperative complications. Cornea. 2010;29:534-540.
    • (2010) Cornea , vol.29 , pp. 534-540
    • Phillips, P.M.1    Terry, M.A.2    Shamie, N.3
  • 14
    • 0033758535 scopus 로고    scopus 로고
    • The role of glaucoma therapy in the need for repeat penetrating keratoplasty
    • Aldave AJ, Rudd JC, Cohen EJ, et al. The role of glaucoma therapy in the need for repeat penetrating keratoplasty. Cornea. 2000;19:772-776.
    • (2000) Cornea , vol.19 , pp. 772-776
    • Aldave, A.J.1    Rudd, J.C.2    Cohen, E.J.3
  • 15
    • 41249102823 scopus 로고    scopus 로고
    • Changes in corneal endothelial cell density and morphology after Ahmed glaucoma valve implantation during the first year of follow up
    • DOI 10.1111/j.1442-9071.2008.01683.x
    • Kim CS, Yim JH, Lee EK, et al. Changes in corneal endothelial cell density and morphology after Ahmed glaucoma valve implantation during the first year of follow-up. Clin Experiment Ophthalmol. 2008;36: 142-147. (Pubitemid 351445147)
    • (2008) Clinical and Experimental Ophthalmology , vol.36 , Issue.2 , pp. 142-147
    • Kim, C.S.1    Yim, J.H.2    Lee, E.K.3    Lee, N.H.4
  • 16
    • 0030764107 scopus 로고    scopus 로고
    • The influence of glaucoma history on graft survival after penetrating keratoplasty
    • DOI 10.1007/BF00947083
    • Reinhard T, Kallmann C, Cepin A, et al. The influence of glaucoma history on graft survival after penetrating keratoplasty. Graefes Arch Clin Exp Ophthalmol. 1997;235:553-557. (Pubitemid 27445360)
    • (1997) Graefe's Archive for Clinical and Experimental Ophthalmology , vol.235 , Issue.9 , pp. 553-557
    • Reinhard, T.1
  • 17
    • 76949094783 scopus 로고    scopus 로고
    • Descemet's stripping with automated endothelial keratoplasty and glaucoma
    • Banitt MR, Chopra V. Descemet's stripping with automated endothelial keratoplasty and glaucoma. Curr Opin Ophthalmol. 2010;21:144-149.
    • (2010) Curr Opin Ophthalmol , vol.21 , pp. 144-149
    • Banitt, M.R.1    Chopra, V.2
  • 18
    • 70349754708 scopus 로고    scopus 로고
    • Early results of Descemet-stripping and automated endothelial keratoplasty (DSAEK) in patients with glaucoma drainage devices
    • Ruiz KM, Sugar J, Tu EY, et al. Early results of Descemet-stripping and automated endothelial keratoplasty (DSAEK) in patients with glaucoma drainage devices. Cornea. 2009;28:959-962.
    • (2009) Cornea , vol.28 , pp. 959-962
    • Ruiz, K.M.1    Sugar, J.2    Tu, E.Y.3
  • 19
    • 79952987826 scopus 로고    scopus 로고
    • Retrospective review of graft dislocation rate associated with Descemet stripping automated endothelial keratoplasty after primary failed penetrating keratoplasty
    • Clements JL, Bouchard CS, Lee WB, et al. Retrospective review of graft dislocation rate associated with Descemet stripping automated endothelial keratoplasty after primary failed penetrating keratoplasty. Cornea. 2010; 30:414-148.
    • (2010) Cornea , vol.30 , pp. 414-148
    • Clements, J.L.1    Bouchard, C.S.2    Lee, W.B.3
  • 20
    • 69249213966 scopus 로고    scopus 로고
    • Visual acuity and intraocular pressure after Descemet's stripping endothelial keratoplasty in eyes with and without preexisting glaucoma
    • Vajaranant TS, Price MO, Price FW, et al. Visual acuity and intraocular pressure after Descemet's stripping endothelial keratoplasty in eyes with and without preexisting glaucoma. Ophthalmology. 2009;116: 1644-1650.
    • (2009) Ophthalmology , vol.116 , pp. 1644-1650
    • Vajaranant, T.S.1    Price, M.O.2    Price, F.W.3
  • 21
    • 1642351133 scopus 로고    scopus 로고
    • Visual acuity measurements
    • DOI 10.1016/j.jcrs.2004.01.014, PII S0886335004001257
    • Holladay JT. Visual acuity measurements. J Cataract Refract Surg. 2004; 30:287-290. (Pubitemid 38366348)
    • (2004) Journal of Cataract and Refractive Surgery , vol.30 , Issue.2 , pp. 287-290
    • Holladay, J.T.1
  • 22
    • 70249116071 scopus 로고    scopus 로고
    • Novel technique in preparing a donor DSAEK lenticule in a patient with a glaucoma drainage device
    • Sansanayudh W, Bahar I, Rootman D. Novel technique in preparing a donor DSAEK lenticule in a patient with a glaucoma drainage device. Br J Ophthalmol. 2009;93:1267-1269.
    • (2009) Br J Ophthalmol , vol.93 , pp. 1267-1269
    • Sansanayudh, W.1    Bahar, I.2    Rootman, D.3
  • 23
    • 0034764711 scopus 로고    scopus 로고
    • Corneal graft survival and intraocular pressure control after penetrating keratoplasty and glaucoma drainage device implantation
    • DOI 10.1016/S0161-6420(01)00803-X, PII S016164200100803X
    • Arroyave CP, Scott IU, Fantes FE, et al. Corneal graft survival and intraocular pressure control after penetrating keratoplasty and glaucoma drainage device implantation. Ophthalmology. 2001;108:1978-1985. (Pubitemid 33032764)
    • (2001) Ophthalmology , vol.108 , Issue.11 , pp. 1978-1985
    • Arroyave, C.P.1    Scott, I.U.2    Fantes, F.E.3    Feuer, W.J.4    Murray, T.G.5
  • 24
    • 0034991411 scopus 로고    scopus 로고
    • Pars plana tube insertion of glaucoma drainage implants and penetrating keratoplasty in patients with coexisting glaucoma and corneal disease
    • DOI 10.1016/S0161-6420(01)00583-8, PII S0161642001005838
    • Sidoti PA, Mosny AY, Ritterband DC, et al. Pars plana tube insertion of glaucoma drainage implants and penetrating keratoplasty in patients with coexisting glaucoma and corneal disease. Ophthalmology. 2001;108: 1050-1058. (Pubitemid 32500020)
    • (2001) Ophthalmology , vol.108 , Issue.6 , pp. 1050-1058
    • Sidoti, P.A.1    Mosny, A.Y.2    Ritterband, D.C.3    Seedor, J.A.4
  • 25
    • 34250698567 scopus 로고    scopus 로고
    • Long-term results of Ahmed glaucoma valve implantation for uveitic glaucoma
    • Papadaki TG, Zacharopoulos IP, Pasquale LR, et al. Long-term results of Ahmed glaucoma valve implantation for uveitic glaucoma. Am J Ophthalmol. 2007;144:62-69.
    • (2007) Am J Ophthalmol , vol.144 , pp. 62-69
    • Papadaki, T.G.1    Zacharopoulos, I.P.2    Pasquale, L.R.3
  • 28
    • 85056065751 scopus 로고    scopus 로고
    • Subconjunctival air leakage after Descemet's stripping automated endothelial keratoplasty (DSAEK) in a post-trabeculectomy eye
    • Ide T, Yoo SH, Leng T, et al. Subconjunctival air leakage after Descemet's stripping automated endothelial keratoplasty (DSAEK) in a post-trabeculectomy eye. Open Ophthalmol J. 2009;3:1-2.
    • (2009) Open Ophthalmol J , vol.3 , pp. 1-2
    • Ide, T.1    Yoo, S.H.2    Leng, T.3
  • 29
    • 50249098074 scopus 로고    scopus 로고
    • Comparison of posterior lamellar keratoplasty techniques to penetrating keratoplasty
    • Bahar I, Kaiserman I, McAllum P, et al. Comparison of posterior lamellar keratoplasty techniques to penetrating keratoplasty. Ophthalmology. 2008; 115:1525-1533.
    • (2008) Ophthalmology , vol.115 , pp. 1525-1533
    • Bahar, I.1    Kaiserman, I.2    McAllum, P.3
  • 31
    • 0037378650 scopus 로고    scopus 로고
    • Graft survival and glaucoma outcome after simultaneous penetrating keratoplasty and Ahmed glaucoma valve implant
    • DOI 10.1097/00003226-200304000-00002
    • Al-Torbak A. Graft survival and glaucoma outcome after simultaneous penetrating keratoplasty and Ahmed glaucoma valve implant. Cornea. 2003;22:194-197. (Pubitemid 36359152)
    • (2003) Cornea , vol.22 , Issue.3 , pp. 194-197
    • Al-Torbak, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.