메뉴 건너뛰기




Volumn , Issue , 2011, Pages

Impact of high level of renewable energy penetration on inter-area oscillation

Author keywords

Damping; geothermal; HVAC; HVDC; interarea oscillation; renewable energy; small signal stability; wind turbine

Indexed keywords

GEOTHERMAL; HVAC; HVDC; INTER-AREA OSCILLATIONS; RENEWABLE ENERGIES; SMALL SIGNAL STABILITY;

EID: 84855751877     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (16)

References (20)
  • 1
    • 0041888150 scopus 로고    scopus 로고
    • The impact of large scale wind power generation on power system oscillations
    • J. G. Slootweg and W. L. Kling, "The impact of large scale wind power generation on power system oscillations," Electric Power Systems Research, vol. 67, 2003.
    • (2003) Electric Power Systems Research , vol.67
    • Slootweg, J.G.1    Kling, W.L.2
  • 4
    • 68349150311 scopus 로고    scopus 로고
    • Impact of Increased Penetration of DFIG-Based Wind Turbine Generators on Transient and Small Signal Stabiltiy of Power Systems
    • August
    • D. Gautam, V. Vittal, and T. Harbour, "Impact of Increased Penetration of DFIG-Based Wind Turbine Generators on Transient and Small Signal Stabiltiy of Power Systems," IEEE Transactions on Power Systems, vol. 24, August 2009.
    • (2009) IEEE Transactions on Power Systems , vol.24
    • Gautam, D.1    Vittal, V.2    Harbour, T.3
  • 5
    • 76649114328 scopus 로고    scopus 로고
    • A Steady-State Voltage Stability Analysis of Power Systems with High Penetrations of Wind
    • E. Vittal, M. O'Mally, and A. Keane, "A Steady-State Voltage Stability Analysis of Power Systems With High Penetrations of Wind," IEEE Transactions on Power Systems, vol. 25, 2010.
    • (2010) IEEE Transactions on Power Systems , vol.25
    • Vittal, E.1    O'Mally, M.2    Keane, A.3
  • 6
    • 33947656500 scopus 로고    scopus 로고
    • Variable Speed Wind Turbines for Power System Stability Enhancement
    • N. R. Ullah and T. Thiringer, "Variable Speed Wind Turbines for Power System Stability Enhancement," IEEE Transactions on Energy Conversion, vol. 22, 2007.
    • (2007) IEEE Transactions on Energy Conversion , vol.22
    • Ullah, N.R.1    Thiringer, T.2
  • 13
  • 14
    • 84855740247 scopus 로고    scopus 로고
    • Studies on the low voltage ride through capability of fully converted wind turbine with PMSG
    • L. Jianlin, H. Shuju, and X. Honghua, "Studies on the low voltage ride through capability of fully converted wind turbine with PMSG,"Automation of Electric Power Systems, vol. 19, 2008.
    • (2008) Automation of Electric Power Systems , vol.19
    • Jianlin, L.1    Shuju, H.2    Honghua, X.3
  • 15
    • 39749103863 scopus 로고    scopus 로고
    • Effect of low voltage ride-through (LVRT) characteristic on voltage stability
    • C.Abbe and G.Joos, "Effect of low voltage ride-through (LVRT) characteristic on voltage stability," IEEE Transactions on Industry Applications, vol. 41, 2005.
    • (2005) IEEE Transactions on Industry Applications , vol.41
    • Abbe, C.1    Joos, G.2
  • 16
    • 33244483622 scopus 로고    scopus 로고
    • Control of permanent magnet generators applied to variable-speed wind-energy systems connected to the grid
    • M. Chinchilla, S. Arnaltes, and J. C. Burgos, "Control of permanent magnet generators applied to variable-speed wind-energy systems connected to the grid," IEEE Transactions on Energy Conversion, vol. 21, 2006.
    • (2006) IEEE Transactions on Energy Conversion , vol.21
    • Chinchilla, M.1    Arnaltes, S.2    Burgos, J.C.3
  • 17
    • 70349135059 scopus 로고    scopus 로고
    • Small signal stability analysis and control of the wind turbine with the direct-drive permanent magnet generator integrated to the grid
    • F. Wua, X. P. Zhangb, and P. Jua, "Small signal stability analysis and control of the wind turbine with the direct-drive permanent magnet generator integrated to the grid " Electric Power Systems Research, vol. 79, 2009.
    • (2009) Electric Power Systems Research , vol.79
    • Wua, F.1    Zhangb, X.P.2    Jua, P.3
  • 18
    • 77957009929 scopus 로고    scopus 로고
    • Stability of a Variable-Speed Permanent Magnet Wind Generator with Weak AC Grids
    • N. P. W. Strachan and D. Jovcic, "Stability of a Variable-Speed Permanent Magnet Wind Generator With Weak AC Grids," IEEE Transactions on Power Delivery, vol. 25, 2010.
    • (2010) IEEE Transactions on Power Delivery , vol.25
    • Strachan, N.P.W.1    Jovcic, D.2
  • 20
    • 84855736335 scopus 로고    scopus 로고
    • PSSE help
    • Siemens Power Transmission & Distribution
    • Siemens Power Transmission & Distribution, "PSSE help," in Basic Power Flow Activity Applications.
    • Basic Power Flow Activity Applications


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.