-
1
-
-
0003486803
-
-
Blackwell Science Ltd., Oxford, chaps. 1 and 2
-
Kanis, J.A., Osteoporosis, Blackwell Science Ltd., Oxford, 1994, chaps. 1 and 2.
-
(1994)
Osteoporosis
-
-
Kanis, J.A.1
-
3
-
-
0014775852
-
Changes in trabecular pattern of the upper end of the femur as an index of osteoporosis
-
Singh, M., Nagrath, A.R., and Malni, P.S., Changes in trabecular pattern of the upper end of the femur as an index of osteoporosis, J. Bone Joint Surg., 52A, 457, 1970.
-
(1970)
J. Bone Joint Surg.
, vol.52A
, pp. 457
-
-
Singh, M.1
Nagrath, A.R.2
Malni, P.S.3
-
4
-
-
0024417652
-
Dietary calcium, physical activity and risk of hip fracture: A prospective study
-
Wickham, C.A.C., Walsh, K., and Cooper, C., Dietary calcium, physical activity and risk of hip fracture: a prospective study, BMJ, 299, 889, 1989.
-
(1989)
BMJ
, vol.299
, pp. 889
-
-
Wickham, C.A.C.1
Walsh, K.2
Cooper, C.3
-
5
-
-
0025267033
-
A new method for automatic recognition of the radiographic trabecular pattern
-
Geraets, W.G.M., Van der Stelt, P.F., Netelenbos, C.J., and Elders, PJ.M., A new method for automatic recognition of the radiographic trabecular pattern, J. Bone Miner. Res., 5, 227, 1990.
-
(1990)
J. Bone Miner. Res.
, vol.5
, pp. 227
-
-
Geraets, W.G.M.1
Van Der Stelt, P.F.2
Netelenbos, C.J.3
Elders, P.J.M.4
-
6
-
-
0006159672
-
Changes in fractal evaluation of trabecular bone in osteoporosis: A preliminary study
-
Birkauser, Basel
-
Benhamou, C.L., Harba, R., Lespessailles, E., Jacquet, G., Touliere, D., and Jennane, R., Changes in fractal evaluation of trabecular bone in osteoporosis: a preliminary study, in Fractals in Biology and Medicine, Birkauser, Basel, 1993, 292.
-
(1993)
Fractals in Biology and Medicine
, pp. 292
-
-
Benhamou, C.L.1
Harba, R.2
Lespessailles, E.3
Jacquet, G.4
Touliere, D.5
Jennane, R.6
-
7
-
-
0029589917
-
Methods for quantitative analysis of trabecular bone structure
-
Cortet, B., Colin, D., Dubois, P., Delcambre, B., and Merchandise, X., Methods for quantitative analysis of trabecular bone structure, Rev. Rhum., 62, 781, 1995.
-
(1995)
Rev. Rhum.
, vol.62
, pp. 781
-
-
Cortet, B.1
Colin, D.2
Dubois, P.3
Delcambre, B.4
Merchandise, X.5
-
8
-
-
0032951671
-
Long-term reproducibility optimization of an X-ray process for bone architectural evaluation during osteoporosis
-
Fidouh, F., Harba, R., Jacquet, G., Loussot, T., and Lespessailles, E., Long-term reproducibility optimization of an X-ray process for bone architectural evaluation during osteoporosis, Phys. Med. Biol., 44, N1, 1999.
-
(1999)
Phys. Med. Biol.
, vol.44
, pp. N1
-
-
Fidouh, F.1
Harba, R.2
Jacquet, G.3
Loussot, T.4
Lespessailles, E.5
-
9
-
-
0027255316
-
Vertebral structure and strength in vivo and
-
Mosekilde, L., Vertebral structure and strength in vivo and in vitro, Calcif. Tissue Int., 53(Suppl. 1), 121, 1993.
-
(1993)
In Vitro, Calcif. Tissue Int.
, vol.53
, pp. 121
-
-
Mosekilde, L.1
-
10
-
-
0031018010
-
The thickness of human vertebral cortical bone and its changes in ageing and osteoporosis: A histomorphometric analysis of the complete spinal column from thirty-seven autopsy cases
-
Ritzel, H. and Amling, M., The thickness of human vertebral cortical bone and its changes in ageing and osteoporosis: a histomorphometric analysis of the complete spinal column from thirty-seven autopsy cases, J. Bone Miner. Res., 12, 89, 1997.
-
(1997)
J. Bone Miner. Res.
, vol.12
, pp. 89
-
-
Ritzel, H.1
Amling, M.2
-
11
-
-
0032998150
-
Accuracy limits for the determination of cortical width and density: The influence of object size and CT imaging parameters
-
Prevrhal, S., Engelke, K., and Kalender, W.A., Accuracy limits for the determination of cortical width and density: the influence of object size and CT imaging parameters, Phys. Med. Biol., 44, 751, 1999.
-
(1999)
Phys. Med. Biol.
, vol.44
, pp. 751
-
-
Prevrhal, S.1
Engelke, K.2
Kalender, W.A.3
-
12
-
-
0026846049
-
Local tomography
-
Faridani, A., Ritman, E.L., and Smith, K.T., Local tomography, SIAM J. Appl. Math., 51, 459, 1992.
-
(1992)
SIAM J. Appl. Math.
, vol.51
, pp. 459
-
-
Faridani, A.1
Ritman, E.L.2
Smith, K.T.3
-
13
-
-
0000294299
-
Local reconstruction applied to x-ray microtomography
-
Chavent, G., Papanicolaou, G., Sacks, P., and Symes, W., Eds., Springer Verlag, New York
-
Ritman, E.L., Dunsmuir, J.H., Faridani, A., Finch, D.V., Smith, K.T., and Thomas, P.J., Local reconstruction applied to x-ray microtomography, in IMA Volumes in Mathematics and Its Applications, Inverse Problems in Wave Propagation, vol. 90, Chavent, G., Papanicolaou, G., Sacks, P., and Symes, W., Eds., Springer Verlag, New York, 1997, 443.
-
(1997)
IMA Volumes in Mathematics and Its Applications, Inverse Problems in Wave Propagation
, vol.90
, pp. 443
-
-
Ritman, E.L.1
Dunsmuir, J.H.2
Faridani, A.3
Finch, D.V.4
Smith, K.T.5
Thomas, P.J.6
-
14
-
-
0344177563
-
Local X-ray tomography for in vivo bone structure examinations
-
Laib, A. and Rüegsegger, P., Local X-ray tomography for in vivo bone structure examinations, Med. Phys., 26, 447, 1999.
-
(1999)
Med. Phys.
, vol.26
, pp. 447
-
-
Laib, A.1
Rüegsegger, P.2
-
15
-
-
0032454920
-
New architectural parameters derived from micro-MRI for the prediction of trabecular bone strength
-
Wehrli, F.W., Hwang, S.N., and Song, H.K., New architectural parameters derived from micro-MRI for the prediction of trabecular bone strength, Technol. Health Care, 6, 307, 1998.
-
(1998)
Technol. Health Care
, vol.6
, pp. 307
-
-
Wehrli, F.W.1
Hwang, S.N.2
Song, H.K.3
-
16
-
-
0002335619
-
Principles and performance of spiral CT
-
Goldman, L.W. and Fowlkes, J.B., Eds., Advanced Medical Publishing, Madison
-
Kalender, W.A., Principles and performance of spiral CT, in Medical CT and Ultrasound: Current Technology and Applications, Goldman, L.W. and Fowlkes, J.B., Eds., Advanced Medical Publishing, Madison, 379, 1995.
-
(1995)
Medical CT and Ultrasound: Current Technology and Applications
, pp. 379
-
-
Kalender, W.A.1
-
17
-
-
58749098097
-
Spiral CT: Medical use and potential industrial applications
-
Kalender, W.A., Engelke, K., and Schaller, S., Spiral CT: medical use and potential industrial applications, Proc. SPIE, 3149, 188, 1997.
-
(1997)
Proc. SPIE
, vol.3149
, pp. 188
-
-
Kalender, W.A.1
Engelke, K.2
Schaller, S.3
-
18
-
-
85057249491
-
A high-speed 3D-pQCT system for structure analysis
-
Kohlbrenner, A. and Rüegsegger, P., A high-speed 3D-pQCT system for structure analysis, Osteoporosis Int. 7, 268, 1997.
-
(1997)
Osteoporosis Int
, vol.7
, pp. 268
-
-
Kohlbrenner, A.1
Rüegsegger, P.2
-
19
-
-
0032463334
-
In vivo high resolution 3D-QCT of the human forearm
-
Laib, A., Häuselmann, H.J., and Rüegsegger, P, In vivo high resolution 3D-QCT of the human forearm, Technol. Health Care, 6, 329, 1998.
-
(1998)
Technol. Health Care
, vol.6
, pp. 329
-
-
Laib, A.1
Häuselmann, H.J.2
Rüegsegger, P.3
-
20
-
-
0030483475
-
Resolution dependency of microstructural properties of cancellous bone based on three-dimensional micro-tomography
-
Müller, R., Koller, B., Hildebrand, T., Laib, A., Gianolini, S., and Rüegsegger, P., Resolution dependency of microstructural properties of cancellous bone based on three-dimensional micro-tomography, Technol. Health Care, 4, 113, 1996.
-
(1996)
Technol. Health Care
, vol.4
, pp. 113
-
-
Müller, R.1
Koller, B.2
Hildebrand, T.3
Laib, A.4
Gianolini, S.5
Rüegsegger, P.6
-
21
-
-
0344301894
-
Calibration of trabecular bone structure measurements of in vivo threedimensional peripheral quantitative computed tomography with 28-^m-resolution microcom-puted tomography
-
Laib, A. and Rüegsegger, P., Calibration of trabecular bone structure measurements of in vivo threedimensional peripheral quantitative computed tomography with 28-^m-resolution microcom-puted tomography, Bone, 24, 35, 1999.
-
(1999)
Bone
, vol.24
, pp. 35
-
-
Laib, A.1
Rüegsegger, P.2
-
22
-
-
0024589979
-
The direct examination of three-dimensional bone architecture in vitro by computed tomography
-
Feldkamp, L.A., Goldstein, S.A., Parfitt, A.M., Jesion, G., and Kleerekoper, M., The direct examination of three-dimensional bone architecture in vitro by computed tomography, J. Bone Miner. Res., 4, 3, 1989.
-
(1989)
J. Bone Miner. Res.
, vol.4
, pp. 3
-
-
Feldkamp, L.A.1
Goldstein, S.A.2
Parfitt, A.M.3
Jesion, G.4
Kleerekoper, M.5
-
23
-
-
0030071062
-
A microtomographic system for the nondestructive evaluation of bone architecture
-
Rüegsegger, P., Koller, B., and Müller, R., A microtomographic system for the nondestructive evaluation of bone architecture, Calcif. Tissue Int., 58, 24, 1996.
-
(1996)
Calcif. Tissue Int.
, vol.58
, pp. 24
-
-
Rüegsegger, P.1
Koller, B.2
Müller, R.3
-
24
-
-
0342323752
-
A 3D microtomographic system with stacked fan beam geometry
-
Kohlbrenner, A., Hämmerle, S., Laib, A., and Rüegsegger, P., A 3D microtomographic system with stacked fan beam geometry, Nucl. Instrum. Meth., A433, 531, 2000.
-
(2000)
Nucl. Instrum. Meth.
, vol.A433
, pp. 531
-
-
Kohlbrenner, A.1
Hämmerle, S.2
Laib, A.3
Rüegsegger, P.4
-
25
-
-
0032461896
-
Three-dimensional in vivo morphometry of trabecular bone in the OVX rat model of osteoporosis
-
Kinney, J.H., Ryaby, J.T., Haupt, D.L., and Lane, N.E., Three-dimensional in vivo morphometry of trabecular bone in the OVX rat model of osteoporosis, Technol. Health Care, 6, 339, 1998.
-
(1998)
Technol. Health Care
, vol.6
, pp. 339
-
-
Kinney, J.H.1
Ryaby, J.T.2
Haupt, D.L.3
Lane, N.E.4
-
26
-
-
0002672224
-
X-ray tomographic microscopy (XTM) using synchrotron radiation
-
Kinney, J.H. and Nichols, M.C., X-ray tomographic microscopy (XTM) using synchrotron radiation, Annu. Rev. Mater. Sci., 22, 121, 1992.
-
(1992)
Annu. Rev. Mater. Sci.
, vol.22
, pp. 121
-
-
Kinney, J.H.1
Nichols, M.C.2
-
27
-
-
0030425049
-
X-ray computed microtomography using synchrotron radiation
-
Bonse, U. and Busch, F., X-ray computed microtomography using synchrotron radiation, Prog. Biophys. Mol. Biol., 65, 133, 1996.
-
(1996)
Prog. Biophys. Mol. Biol.
, vol.65
, pp. 133
-
-
Bonse, U.1
Busch, F.2
-
28
-
-
0028354656
-
3D computed X-ray tomography of human cancellous bone at 8 ¡xm spatial and 10~4 energy resolution
-
4 energy resolution, Bone Miner., 25, 25, 1994.
-
(1994)
Bone Miner.
, vol.25
, pp. 25
-
-
Bonse, U.1
Busch, F.2
Günnewig, O.3
Beckmann, F.4
Pahl, R.5
Delling, G.6
Hahn, M.7
Graeff, W.8
-
29
-
-
4244111955
-
Radio frequency coils
-
Thomas, S.R. and Dixon, R.L., Eds., American Institute of Physics, New York
-
Hayes, C.E., Edelstein, W.A., and Schenk, J.F., Radio frequency coils, in NMR in Medicine: The Instrumentation and Clinical Applications, Thomas, S.R. and Dixon, R.L., Eds., American Institute of Physics, New York 1985, 142.
-
(1985)
NMR in Medicine: The Instrumentation and Clinical Applications
, pp. 142
-
-
Hayes, C.E.1
Edelstein, W.A.2
Schenk, J.F.3
-
30
-
-
0027413855
-
High-resolution variable flip angle 3D MR imaging of trabecular microstructure
-
Jara, H., Wehrli, F.W., Chung, H., and Ford, J.C., High-resolution variable flip angle 3D MR imaging of trabecular microstructure in vivo, Magn. Reson. Med., 29, 528, 1993.
-
(1993)
In Vivo, Magn. Reson. Med.
, vol.29
, pp. 528
-
-
Jara, H.1
Wehrli, F.W.2
Chung, H.3
Ford, J.C.4
-
31
-
-
0027312646
-
Magnetic resonance microscopy in rat skeletal research
-
Kapadia, R.D., High, W.B., Soulleveld, H.A., Bertolini, D., and Sarkar, S.K., Magnetic resonance microscopy in rat skeletal research, Magn. Reson. Med., 30, 247, 1993.
-
(1993)
Magn. Reson. Med.
, vol.30
, pp. 247
-
-
Kapadia, R.D.1
High, W.B.2
Soulleveld, H.A.3
Bertolini, D.4
Sarkar, S.K.5
-
32
-
-
0027280104
-
Potential role of nuclear magnetic resonance for the evaluation of trabecular bone quality
-
Wehrli, F.W., Ford, J.C., Chung, H.W., Wehrli, S.L., Williams, J.L., Grimm, M.J., Kugelmass, S.D., and Jara, H., Potential role of nuclear magnetic resonance for the evaluation of trabecular bone quality, Calcif. Tissue Int., 53, S162, 1993.
-
(1993)
Calcif. Tissue Int.
, vol.53
, pp. S162
-
-
Wehrli, F.W.1
Ford, J.C.2
Chung, H.W.3
Wehrli, S.L.4
Williams, J.L.5
Grimm, M.J.6
Kugelmass, S.D.7
Jara, H.8
-
33
-
-
0030062696
-
Trabecular bone morphology from micro-magnetic resonance imaging
-
Hipp, J.A., Jansujwicz, A., Simmons, C.A., and Snyder, B.D., Trabecular bone morphology from micro-magnetic resonance imaging, J. Bone Miner. Res., 11, 286, 1996.
-
(1996)
J. Bone Miner. Res.
, vol.11
, pp. 286
-
-
Hipp, J.A.1
Jansujwicz, A.2
Simmons, C.A.3
Snyder, B.D.4
-
34
-
-
0028293109
-
A bayesian approach to subvoxel tissue classification in NMR microscopic images of trabecular bone
-
Wu, Z., Chung, H.W., and Wehrli, F.W., A bayesian approach to subvoxel tissue classification in NMR microscopic images of trabecular bone, Magn. Reson. Med., 31, 302, 1994.
-
(1994)
Magn. Reson. Med.
, vol.31
, pp. 302
-
-
Wu, Z.1
Chung, H.W.2
Wehrli, F.W.3
-
35
-
-
0002630764
-
NMR microscopy using projection-reconstruction
-
Blümich, B. and Kuhn, W., Eds., VCH Publishers, New York
-
Zhou, X. and Lauterbur, P.C., NMR microscopy using projection-reconstruction, in Magnetic Resonance Microscopy, Blümich, B. and Kuhn, W., Eds., VCH Publishers, New York, 1992, 3.
-
(1992)
Magnetic Resonance Microscopy
, pp. 3
-
-
Zhou, X.1
Lauterbur, P.C.2
-
36
-
-
0029154457
-
Three-dimensional nuclear magnetic resonance microimaging of trabecular bone
-
Chung, H., Wehrli, F.W., Williams, J.L., and Wehrli, S.L., Three-dimensional nuclear magnetic resonance microimaging of trabecular bone, J. Bone Miner. Res., 10, 1452, 1995.
-
(1995)
J. Bone Miner. Res.
, vol.10
, pp. 1452
-
-
Chung, H.1
Wehrli, F.W.2
Williams, J.L.3
Wehrli, S.L.4
-
37
-
-
0028946377
-
Quantitative analysis of trabecular microstructure by 400 MHz nuclear magnetic resonance imaging
-
Chung, H., Wehrli, F.W., Williams, J.L., Kugelmass, S.D., and Wehrli, S.L., Quantitative analysis of trabecular microstructure by 400 MHz nuclear magnetic resonance imaging, J. Bone Miner. Res., 10, 803, 1995.
-
(1995)
J. Bone Miner. Res.
, vol.10
, pp. 803
-
-
Chung, H.1
Wehrli, F.W.2
Williams, J.L.3
Kugelmass, S.D.4
Wehrli, S.L.5
-
38
-
-
0030796048
-
Probability-based structural parameters from three-dimensional nuclear magnetic resonance images as predictors of trabecular bone strength
-
Hwang, S.N. and Wehrli, F.W., Probability-based structural parameters from three-dimensional nuclear magnetic resonance images as predictors of trabecular bone strength, Med. Phys., 24, 1255, 1997.
-
(1997)
Med. Phys.
, vol.24
, pp. 1255
-
-
Hwang, S.N.1
Wehrli, F.W.2
-
39
-
-
0031032812
-
Correlation of trabecular bone structure with age, bone mineral density, and osteoporotic status: In vivo studies in the distal radius using high resolution magnetic resonance imaging
-
Majumdar, S., Genant, H.K., Grampp, S., Newitt, D.C., Truong, V.H., Lin, J.C., and Mathur, A., Correlation of trabecular bone structure with age, bone mineral density, and osteoporotic status: in vivo studies in the distal radius using high resolution magnetic resonance imaging, J. Bone Miner. Res., 12, 111, 1997.
-
(1997)
J. Bone Miner. Res.
, vol.12
, pp. 111
-
-
Majumdar, S.1
Genant, H.K.2
Grampp, S.3
Newitt, D.C.4
Truong, V.H.5
Lin, J.C.6
Mathur, A.7
-
40
-
-
0031837398
-
In vivo high resolution MRI of the calcaneus: Differences in trabecular structure in osteoporosis patients
-
Link, T.M., Majumdar, S., Augat, P., Lin, J.C., Newitt, D., Lu, Y., Lane, N.E., and Genant, H.K., In vivo high resolution MRI of the calcaneus: differences in trabecular structure in osteoporosis patients, J. Bone Miner. Res., 13, 1175, 1998.
-
(1998)
J. Bone Miner. Res.
, vol.13
, pp. 1175
-
-
Link, T.M.1
Majumdar, S.2
Augat, P.3
Lin, J.C.4
Newitt, D.5
Lu, Y.6
Lane, N.E.7
Genant, H.K.8
-
41
-
-
0344141607
-
Comparison of structure extraction methods for in vivo trabecular bone measurements
-
Laib, A. and Rüegsegger, P., Comparison of structure extraction methods for in vivo trabecular bone measurements, Comput. Med. Imag. Graphics, 23, 69, 1999.
-
(1999)
Comput. Med. Imag. Graphics
, vol.23
, pp. 69
-
-
Laib, A.1
Rüegsegger, P.2
-
42
-
-
0031020931
-
A new method for the model independent assessment of thickness in three-dimensional images
-
Hildebrand, T. and Rüegsegger, P., A new method for the model independent assessment of thickness in three-dimensional images, J. Microsc., 185, 67, 1997.
-
(1997)
J. Microsc.
, vol.185
, pp. 67
-
-
Hildebrand, T.1
Rüegsegger, P.2
-
43
-
-
0020509916
-
Relationship between surface, volume, and thickness of iliac trabecular bone in ageing and in osteoporosis
-
Parfitt, A.M., Mathews, C.H.E., Villanueva, A.R., Kleerekoper, M., Frame, B., and Rao, D.S., Relationship between surface, volume, and thickness of iliac trabecular bone in ageing and in osteoporosis, Calcif. Tissue Int., 72, 1396, 1983.
-
(1983)
Calcif. Tissue Int.
, vol.72
, pp. 1396
-
-
Parfitt, A.M.1
Mathews, C.H.E.2
Villanueva, A.R.3
Kleerekoper, M.4
Frame, B.5
Rao, D.S.6
-
44
-
-
0023488581
-
Bone histomorphometry: Standardization of nomenclature, symbols and units, report of the ASBMR histomorphometry nomenclature committee
-
Parfitt, A.M., Drezner, M.K., Glorieux, F.H., Kanis, F.H., Malluche, H., Meunier, P.J., Ott, S.M., and Recker, R.R., Bone histomorphometry: standardization of nomenclature, symbols and units, report of the ASBMR histomorphometry nomenclature committee, J. Bone Miner. Res., 21, 595, 1987.
-
(1987)
J. Bone Miner. Res.
, vol.21
, pp. 595
-
-
Parfitt, A.M.1
Drezner, M.K.2
Glorieux, F.H.3
Kanis, F.H.4
Malluche, H.5
Meunier, P.J.6
Ott, S.M.7
Recker, R.R.8
-
45
-
-
0033065526
-
Load transfer analysis of the distal radius from in vivo high-resolution CT-imaging
-
Ulrich, D., Van Rietbergen, B., Laib, A., and Rüegsegger, P., Load transfer analysis of the distal radius from in vivo high-resolution CT-imaging, J. Biomech., 32, 821, 1999.
-
(1999)
J. Biomech.
, vol.32
, pp. 821
-
-
Ulrich, D.1
Van Rietbergen, B.2
Laib, A.3
Rüegsegger, P.4
-
46
-
-
0028298724
-
Volume and surface area of viable chondrocytes in situ using geometric modelling of serial confocal sections
-
Guilak, F., Volume and surface area of viable chondrocytes in situ using geometric modelling of serial confocal sections, J. Microsc., 173, 245, 1994.
-
(1994)
J. Microsc.
, vol.173
, pp. 245
-
-
Guilak, F.1
-
47
-
-
0023381475
-
Marching cubes: A high resolution 3D surface construction algorithm
-
Lorensen, W.E. and Cline, H.E., Marching cubes: a high resolution 3D surface construction algorithm, Comput. Graphics, 21, 163, 1987.
-
(1987)
Comput. Graphics
, vol.21
, pp. 163
-
-
Lorensen, W.E.1
Cline, H.E.2
-
48
-
-
0027417991
-
Quantification of connectivity in cancellous bone, with special emphasis on 3-D reconstructions
-
Odgaard, A. and Gundersen, H.J.G., Quantification of connectivity in cancellous bone, with special emphasis on 3-D reconstructions, Bone, 14, 173, 1993.
-
(1993)
Bone
, vol.14
, pp. 173
-
-
Odgaard, A.1
Gundersen, H.J.G.2
-
49
-
-
0021388724
-
Characterization of microstructural anisotropy in orthotropic materials using a second rank tensor
-
Harrigan, T.P. and Mann, R.W., Characterization of microstructural anisotropy in orthotropic materials using a second rank tensor, J. Mater. Sci., 19, 761, 1984.
-
(1984)
J. Mater. Sci.
, vol.19
, pp. 761
-
-
Harrigan, T.P.1
Mann, R.W.2
-
50
-
-
0022097744
-
The relationship between the elasticity tensor and the fabric tensor
-
Cowin, S.C., The relationship between the elasticity tensor and the fabric tensor, Mech. Mater., 4, 137, 1985.
-
(1985)
Mech. Mater.
, vol.4
, pp. 137
-
-
Cowin, S.C.1
-
51
-
-
2942730560
-
Quantification of bone microarchitecture with the structure model index
-
Hildebrand, T. and Rüegsegger, P., Quantification of bone microarchitecture with the structure model index, Comp. Methods Biomech. Biomed. Eng., 1, 15, 1997.
-
(1997)
Comp. Methods Biomech. Biomed. Eng.
, vol.1
, pp. 15
-
-
Hildebrand, T.1
Rüegsegger, P.2
-
52
-
-
4544377401
-
Fractal geometry applied to the architecture of cancellous bone biopsy specimens
-
Weinstein, R.S., Majumdar, S., and Genant, H.K., Fractal geometry applied to the architecture of cancellous bone biopsy specimens, Bone, 13, A38, 1992.
-
(1992)
Bone
, vol.13
, pp. A38
-
-
Weinstein, R.S.1
Majumdar, S.2
Genant, H.K.3
-
53
-
-
0027244314
-
Trabecular bone does not have a fractal structure on light microscopy
-
Cross, S.S., Rogers, S., Silcocks, P.B., and Cotton, D.W.K., Trabecular bone does not have a fractal structure on light microscopy, J. Pathol., 170, 311, 1993.
-
(1993)
J. Pathol.
, vol.170
, pp. 311
-
-
Cross, S.S.1
Rogers, S.2
Silcocks, P.B.3
Cotton, D.W.K.4
-
54
-
-
0028081418
-
On fractal dimension of trabecular structure
-
Chung, H.W., Chu, C.C., Underweiser, M., and Wehrli, F.W., On fractal dimension of trabecular structure, Med. Phys., 21, 1535, 1994.
-
(1994)
Med. Phys.
, vol.21
, pp. 1535
-
-
Chung, H.W.1
Chu, C.C.2
Underweiser, M.3
Wehrli, F.W.4
-
55
-
-
0027689405
-
Application of fractal geometry techniques to the study of trabecular bone
-
Majumdar, S., Weinstein, R.S., and Prasad, R.R., Application of fractal geometry techniques to the study of trabecular bone, Med. Phys., 20, 1611, 1993.
-
(1993)
Med. Phys.
, vol.20
, pp. 1611
-
-
Majumdar, S.1
Weinstein, R.S.2
Prasad, R.R.3
-
56
-
-
0030898662
-
Three-dimensional methods for quantification of cancellous bone architecture
-
Odgaard, A., Three-dimensional methods for quantification of cancellous bone architecture, Bone, 20, 315, 1997.
-
(1997)
Bone
, vol.20
, pp. 315
-
-
Odgaard, A.1
-
57
-
-
0028153803
-
Non-invasive bone biopsy: A new method to analyse and display the three-dimensional structure of trabecular bone
-
Müller, R., Hildebrand, T., and Rüegsegger, P., Non-invasive bone biopsy: a new method to analyse and display the three-dimensional structure of trabecular bone, Phys. Med. Biol., 39, 145, 1994.
-
(1994)
Phys. Med. Biol.
, vol.39
, pp. 145
-
-
Müller, R.1
Hildebrand, T.2
Rüegsegger, P.3
-
58
-
-
0031978185
-
The relationship between three-dimensional connectivity and the elastic properties of trabecular bone
-
Kinney, J.H. and Ladd, A.J.C., The relationship between three-dimensional connectivity and the elastic properties of trabecular bone, J. Bone Miner. Res., 13, 839, 1998.
-
(1998)
J. Bone Miner. Res.
, vol.13
, pp. 839
-
-
Kinney, J.H.1
Ladd, A.2
-
59
-
-
84985186258
-
A new method for the two-dimensional analysis of bone structure in human iliac crest biopsies
-
Garrahan, N.J., Mellish, R.W.E., and Compston, J.E., A new method for the two-dimensional analysis of bone structure in human iliac crest biopsies, J. Microsc., 142, 341, 1986.
-
(1986)
J. Microsc.
, vol.142
, pp. 341
-
-
Garrahan, N.J.1
Mellish, R.W.E.2
Compston, J.E.3
-
60
-
-
0006588265
-
Rods or plates: A new algorithm to characterize bone structure using 3D magnetic resonance imaging
-
Stampa, B., Kühl, B., Heller, M., and Glüer, C.C., Rods or plates: a new algorithm to characterize bone structure using 3D magnetic resonance imaging, Osteoporosis Int., 8, 503, 1998.
-
(1998)
Osteoporosis Int.
, vol.8
, pp. 503
-
-
Stampa, B.1
Kühl, B.2
Heller, M.3
Glüer, C.C.4
-
61
-
-
0345596449
-
Morphometric analysis of human bone biopsies: A quantitative structural comparison of histological sections and micro-computed tomography
-
Müller, R., Van Campenhout, H., Van Damme, B., Van der Perre, G., Dequeker, J., Hildebrand, T., and Rüegsegger, P., Morphometric analysis of human bone biopsies: a quantitative structural comparison of histological sections and micro-computed tomography, Bone, 23, 59, 1998.
-
(1998)
Bone
, vol.23
, pp. 59
-
-
Müller, R.1
Van Campenhout, H.2
Van Damme, B.3
Van Der Perre, G.4
Dequeker, J.5
Hildebrand, T.6
Rüegsegger, P.7
-
62
-
-
0002042828
-
Histomorphometrie
-
Kuhlencordt, F. and Bartelsheimer, H., Eds., Springer Verlag, Berlin
-
Schenk, R.K. and Olah, A.J., Histomorphometrie, in Handbuch der inneren Medizin VI/1A, Knochen Gelenke Muskeln, Kuhlencordt, F. and Bartelsheimer, H., Eds., Springer Verlag, Berlin, 1980, 437.
-
(1980)
Handbuch Der Inneren Medizin VI/1A, Knochen Gelenke Muskeln
, pp. 437
-
-
Schenk, R.K.1
Olah, A.J.2
-
63
-
-
0033047422
-
Direct 3-D morphometric analysis of human cancellous bone: Microstructural data from spine, femur, iliac crest, and calcaneus
-
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., and Rüegsegger, P., Direct 3-D morphometric analysis of human cancellous bone: microstructural data from spine, femur, iliac crest, and calcaneus, J. Bone Miner. Res., 14, 1167, 1999.
-
(1999)
J. Bone Miner. Res.
, vol.14
, pp. 1167
-
-
Hildebrand, T.1
Laib, A.2
Müller, R.3
Dequeker, J.4
Rüegsegger, P.5
-
64
-
-
0032454162
-
Applications of micro-CT and MR microscopy to study pre-clinical models of osteoporosis and osteoarthritis
-
Kapadia, R.D., Stroup, G.B., Badger, A.M., Koller, B., Levin, J.M., Coatney, R.W., Dodds, R.A., Liang, X., Lark, M.W., and Gowen, M., Applications of micro-CT and MR microscopy to study pre-clinical models of osteoporosis and osteoarthritis, Technol. Health Care, 6, 361, 1998.
-
(1998)
Technol. Health Care
, vol.6
, pp. 361
-
-
Kapadia, R.D.1
Stroup, G.B.2
Badger, A.M.3
Koller, B.4
Levin, J.M.5
Coatney, R.W.6
Dodds, R.A.7
Liang, X.8
Lark, M.W.9
Gowen, M.10
-
65
-
-
0029880186
-
Genetic variability in adult bone density among inbred strains of mice
-
Beamer, W.G., Donahue, L.R., Rosen, C.J., and Baylink, D.J., Genetic variability in adult bone density among inbred strains of mice, Bone, 18, 397, 1996.
-
(1996)
Bone
, vol.18
, pp. 397
-
-
Beamer, W.G.1
Donahue, L.R.2
Rosen, C.J.3
Baylink, D.J.4
-
66
-
-
0028910321
-
In vivo, three-dimensional microscopy of trabecular bone
-
Kinney, J.H., Lane, N.E., and Haupt, E.L., In vivo, three-dimensional microscopy of trabecular bone, J. Bone Miner. Res., 10, 264, 1995.
-
(1995)
J. Bone Miner. Res.
, vol.10
, pp. 264
-
-
Kinney, J.H.1
Lane, N.E.2
Haupt, E.L.3
-
67
-
-
0001155449
-
Percolation and cluster distribution. I. Cluster multiple labeling technique and critical concentration algorithm
-
Hoshen, J. and Kopelman, R., Percolation and cluster distribution. I. Cluster multiple labeling technique and critical concentration algorithm, Phys. Rev. B, 15, 3438, 1976.
-
(1976)
Phys. Rev. B
, vol.15
, pp. 3438
-
-
Hoshen, J.1
Kopelman, R.2
-
68
-
-
0030934375
-
In vivo assessment of trabecular bone structure at the distal radius from high-resolution magnetic resonance images
-
Gordon, C.L., Webber, C.E., Christoforou, N., and Nahmias, C., In vivo assessment of trabecular bone structure at the distal radius from high-resolution magnetic resonance images, Med. Phys., 24, 585, 1997.
-
(1997)
Med. Phys.
, vol.24
, pp. 585
-
-
Gordon, C.L.1
Webber, C.E.2
Christoforou, N.3
Nahmias, C.4
-
69
-
-
0031915851
-
Noninvasive assessment of cancellous bone volume and structure in the forearm by magnetic resonance microimaging and image processing
-
Wehrli, F.W., Hwang, S.N., Ma, J., Song, H.K., Ford, J.C., and Haddad, J.G., Noninvasive assessment of cancellous bone volume and structure in the forearm by magnetic resonance microimaging and image processing, Radiology, 206, 347, 1998.
-
(1998)
Radiology
, vol.206
, pp. 347
-
-
Wehrli, F.W.1
Hwang, S.N.2
Ma, J.3
Song, H.K.4
Ford, J.C.5
Haddad, J.G.6
-
70
-
-
0000943418
-
In vivo assessment of trabecular bone structure of the human phalanges using high resolution magnetic resonance imaging
-
Kuehn, B., Stampa, B., Heller, M., and Glueer, C., In vivo assessment of trabecular bone structure of the human phalanges using high resolution magnetic resonance imaging, Osteoporos Int., 7, 291, 1997.
-
(1997)
Osteoporos Int.
, vol.7
, pp. 291
-
-
Kuehn, B.1
Stampa, B.2
Heller, M.3
Glueer, C.4
-
71
-
-
58749089520
-
Biomechanical competence of microstructural bone in the progress of adaptive bone remodeling
-
Müller, R. and Hayes, W.C., Biomechanical competence of microstructural bone in the progress of adaptive bone remodeling, Proc. SPIE, 3149, 69, 1997.
-
(1997)
Proc. SPIE
, vol.3149
, pp. 69
-
-
Müller, R.1
Hayes, W.C.2
-
73
-
-
0006094392
-
Radioautographic visualization of bone formation in the rat
-
Leblond, C.P., Willimson, G.W., Bilanger, L.F., and Robichon, J., Radioautographic visualization of bone formation in the rat, Am. J. Anat., 86, 289, 1950.
-
(1950)
Am. J. Anat.
, vol.86
, pp. 289
-
-
Leblond, C.P.1
Willimson, G.W.2
Bilanger, L.F.3
Robichon, J.4
-
74
-
-
0032462562
-
Micro-CT imaging of structure-to-function relationship of bone microstructure and associated vascular involvement
-
Ritman, E.L., Bolander, M.E., Fitzpatrick, L.A., and Turner, R.T., Micro-CT imaging of structure-to-function relationship of bone microstructure and associated vascular involvement, Technol. Health Care, 6, 403, 1998.
-
(1998)
Technol. Health Care
, vol.6
, pp. 403
-
-
Ritman, E.L.1
Bolander, M.E.2
Fitzpatrick, L.A.3
Turner, R.T.4
-
75
-
-
0032468805
-
Micro-CT examinations of trabecular bone samples at different resolutions: 14, 7, and 2 micron level
-
Peyrin, R., Salome, M., Cloettens, P., Laval-Jeantet, A.M., Ritman, E., and Rüegsegger, P., Micro-CT examinations of trabecular bone samples at different resolutions: 14, 7, and 2 micron level, Technol. Health Care, 6, 391, 1998.
-
(1998)
Technol. Health Care
, vol.6
, pp. 391
-
-
Peyrin, R.1
Salome, M.2
Cloettens, P.3
Laval-Jeantet, A.M.4
Ritman, E.5
Rüegsegger, P.6
|