메뉴 건너뛰기




Volumn , Issue , 2011, Pages 357-360

New technologies for nanobiosensing and their applications to real-time monitoring

Author keywords

[No Author keywords available]

Indexed keywords

AMPEROMETRIC BIOSENSORS; CMOS COMPATIBLE; FLOW CONDITION; FUNCTIONALIZATIONS; FUNCTIONALIZED; MICROTECHNOLOGY; NANO-STRUCTURED; ON-LINE DETECTION; REAL TIME MONITORING; REAL-TIME DETECTION; SCREEN PRINTED ELECTRODES; SILICON SUBSTRATES; STRUCTURATION; WORKING ELECTRODE;

EID: 84855700492     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/BioCAS.2011.6107801     Document Type: Conference Paper
Times cited : (13)

References (16)
  • 1
    • 79959634906 scopus 로고    scopus 로고
    • Quantum dots and wires to improve enzymes-based electrochemical bio-sensing
    • Springer Berlin Heidelberg
    • Sandro Carrara, Cristina Boero, and Giovanni Micheli. Quantum dots and wires to improve enzymes-based electrochemical bio-sensing. In Nano-Net, volume 20, pages 189-199. Springer Berlin Heidelberg, 2009.
    • (2009) Nano-Net , vol.20 , pp. 189-199
    • Carrara, S.1    Boero, C.2    Micheli, G.3
  • 2
    • 0035984039 scopus 로고    scopus 로고
    • Poly(dimethylsiloxane) as a material for fabricating microfluidic devices
    • J. C. McDonald and G. M. Whitesides. Poly(dimethylsiloxane) as a material for fabricating microfluidic devices. Accounts of Chemical Research, 35(7):491-499, 2002.
    • (2002) Accounts of Chemical Research , vol.35 , Issue.7 , pp. 491-499
    • McDonald, J.C.1    Whitesides, G.M.2
  • 3
    • 79955943670 scopus 로고    scopus 로고
    • Dependence of the quality of adhesion between poly(dimethylsiloxane) and glass surfaces on the composition of the oxidizing plasma
    • K. Chau, B. Millare, A. Lin, S. Upadhyayula, V. Nuñez, H. Xu, and V. Vullev. Dependence of the quality of adhesion between poly(dimethylsiloxane) and glass surfaces on the composition of the oxidizing plasma. Microfluidics and Nanofluidics, 10:907-917, 2011.
    • (2011) Microfluidics and Nanofluidics , vol.10 , pp. 907-917
    • Chau, K.1    Millare, B.2    Lin, A.3    Upadhyayula, S.4    Nuñez, V.5    Xu, H.6    Vullev, V.7
  • 4
    • 79959656781 scopus 로고    scopus 로고
    • Targeting of multiple metabolites in neural cells monitored by using protein-based carbon nanotubes
    • Cristina Boero, Sandro Carrara, Giovanna Del Vecchio, Laura Calz, and Giovanni De Micheli. Targeting of multiple metabolites in neural cells monitored by using protein-based carbon nanotubes. Sensors and Actuators B: Chemical, 157(1):216-224, 2011.
    • (2011) Sensors and Actuators B: Chemical , vol.157 , Issue.1 , pp. 216-224
    • Boero, C.1    Carrara, S.2    Del Vecchio, G.3    Calz, L.4    De Micheli, G.5
  • 5
    • 23044477090 scopus 로고    scopus 로고
    • Functionalized conducting polymer as an enzyme-immobilizing substrate: An amperometric glutamate microbiosensor for in vivo measurements
    • M. A. Rahman, N. Kwon, M. Won, E. S. Choe, and Y. Shim. Functionalized conducting polymer as an enzyme-immobilizing substrate: an amperometric glutamate microbiosensor for in vivo measurements. Analytical Chemistry, 77(15):4854-4860, 2005.
    • (2005) Analytical Chemistry , vol.77 , Issue.15 , pp. 4854-4860
    • Rahman, M.A.1    Kwon, N.2    Won, M.3    Choe, E.S.4    Shim, Y.5
  • 6
    • 33646046164 scopus 로고    scopus 로고
    • Bienzymatic analytical microreactors for glucose, lactate, ethanol, galactose and l-amino acid monitoring in cell culture media
    • V. Vojinovic, F.M.F. Esteves, J.M.S. Cabral, and L.P. Fonseca. Bienzymatic analytical microreactors for glucose, lactate, ethanol, galactose and l-amino acid monitoring in cell culture media. Analytica Chimica Acta, 565(2):240-249, 2006.
    • (2006) Analytica Chimica Acta , vol.565 , Issue.2 , pp. 240-249
    • Vojinovic, V.1    Esteves, F.M.F.2    Cabral, J.M.S.3    Fonseca, L.P.4
  • 7
    • 33745091245 scopus 로고    scopus 로고
    • Cell based assays for diagnostic and therapy on multiparametric biosensor chips with an intelligent mobile lab
    • J. Wiest, M. Schmidhuber, J. Ressler, A. Scholz, M. Brischwein, and B. Wolf. Cell based assays for diagnostic and therapy on multiparametric biosensor chips with an intelligent mobile lab. In IFMBE Proceedings, volume 10, pages 132-135, 2005.
    • (2005) IFMBE Proceedings , vol.10 , pp. 132-135
    • Wiest, J.1    Schmidhuber, M.2    Ressler, J.3    Scholz, A.4    Brischwein, M.5    Wolf, B.6
  • 8
    • 44649126820 scopus 로고    scopus 로고
    • Cell-based microfluidic biochip for the electrochemical real-time monitoring of glucose and oxygen
    • N. Pereira Rodrigues, Y. Sakai, and T. Fujii. Cell-based microfluidic biochip for the electrochemical real-time monitoring of glucose and oxygen. Sensors and Actuators B: Chemical, 132(2):608-613, 2008.
    • (2008) Sensors and Actuators B: Chemical , vol.132 , Issue.2 , pp. 608-613
    • Pereira Rodrigues, N.1    Sakai, Y.2    Fujii, T.3
  • 10
    • 29144446184 scopus 로고    scopus 로고
    • Electrochemistry and electroanalytical applications of carbon nanotubes: A review
    • K. Gong, Y. Yan, M. Zhang, L. Su, S. Xiong, and L. Mao. Electrochemistry and electroanalytical applications of carbon nanotubes: a review. Analytical science, 21:1383-1393, 2005.
    • (2005) Analytical Science , vol.21 , pp. 1383-1393
    • Gong, K.1    Yan, Y.2    Zhang, M.3    Su, L.4    Xiong, S.5    Mao, L.6
  • 11
    • 0037089257 scopus 로고    scopus 로고
    • Theoretical comparison between field emission from single-wall and multi-wall carbon nanotubes
    • A. Mayer, N. M. Miskovsky, and P. H. Cutler. Theoretical comparison between field emission from single-wall and multi-wall carbon nanotubes. Physical Review B, 65(15):155420, 2002.
    • (2002) Physical Review B , vol.65 , Issue.15 , pp. 155420
    • Mayer, A.1    Miskovsky, N.M.2    Cutler, P.H.3
  • 12
    • 46149102221 scopus 로고    scopus 로고
    • Screenprinted electrodes based on carbon nanotubes and cytochrome p450scc for highly sensitive cholesterol biosensors
    • S. Carrara, V.V. Shumyantseva, A.I. Archakov, and B. Samorì. Screenprinted electrodes based on carbon nanotubes and cytochrome p450scc for highly sensitive cholesterol biosensors. Biosensensors and Bioelectronics, 24(1):148-150, 2008.
    • (2008) Biosensensors and Bioelectronics , vol.24 , Issue.1 , pp. 148-150
    • Carrara, S.1    Shumyantseva, V.V.2    Archakov, A.I.3    Samorì, B.4
  • 13
    • 0037420379 scopus 로고    scopus 로고
    • Solubilization of carbon nanotubes by nafion toward the preparation of amperometric biosensors
    • J. Wang, M. Musameh, and Y. Lin. Solubilization of carbon nanotubes by nafion toward the preparation of amperometric biosensors. Journal of the American Chemical Society, 125(9):2408-2409, 2003.
    • (2003) Journal of the American Chemical Society , vol.125 , Issue.9 , pp. 2408-2409
    • Wang, J.1    Musameh, M.2    Lin, Y.3
  • 14
    • 79955612831 scopus 로고    scopus 로고
    • Highly sensitive carbon nanotube-based sensing for lactate and glucose monitoring in cell culture
    • C. Boero, S. Carrara, G. Del Vecchio, L. Calzá and, and G. De Micheli. Highly sensitive carbon nanotube-based sensing for lactate and glucose monitoring in cell culture. IEEE Transactions on NanoBioscience, 10(1):59-67, 2011.
    • (2011) IEEE Transactions on NanoBioscience , vol.10 , Issue.1 , pp. 59-67
    • Boero, C.1    Carrara, S.2    Del Vecchio, G.3    Calzá, L.4    De Micheli, G.5
  • 15
    • 0034325074 scopus 로고    scopus 로고
    • Miniaturized real-time monitoring system for -lactate and glucose using microfabricated multi-enzyme sensors
    • J. Perdomo, H. Hinkers, C. Sundermeier, W. Seifert, O. Martnez Morell, and M. Knoll. Miniaturized real-time monitoring system for -lactate and glucose using microfabricated multi-enzyme sensors. Biosensors and Bioelectronics, 15(9-10):515-522, 2000.
    • (2000) Biosensors and Bioelectronics , vol.15 , Issue.9-10 , pp. 515-522
    • Perdomo, J.1    Hinkers, H.2    Sundermeier, C.3    Seifert, W.4    Martnez Morell, O.5    Knoll, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.