메뉴 건너뛰기




Volumn , Issue , 2011, Pages 94-97

VHDL implementation of the Biostator II glucose control algorithm for critical care

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD GLUCOSE; BLOOD GLUCOSE LEVEL; CMOS ASIC; CRITICAL CARE; GLUCOSE CONTROL; GLUCOSE SENSING; HARDWARE IMPLEMENTATIONS; INSULIN PUMPS; OPTIMISATIONS; TYPE 1 DIABETES MELLITUS; VHDL IMPLEMENTATION;

EID: 84855654230     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/BioCAS.2011.6107735     Document Type: Conference Paper
Times cited : (6)

References (9)
  • 1
    • 3042685712 scopus 로고    scopus 로고
    • Intensive insulin therapy for critically ill patients
    • K. Lewis, S. Kane-Gill, M. Bobek, and J. Dasta, "Intensive insulin therapy for critically ill patients," The Annals of pharmacotherapy, vol. 38, no. 7, p. 1243, 2004.
    • (2004) Annals of Pharmacotherapy , vol.38 , Issue.7 , pp. 1243
    • Lewis, K.1    Kane-Gill, S.2    Bobek, M.3    Dasta, J.4
  • 2
    • 0019728673 scopus 로고
    • Comparison of algorithms for the closed-loop control of blood glucose using the artificial beta cell
    • H. Broekhuyse, H. Nelson, B. Zinman, and A. Albisser, "Comparison of algorithms for the closed-loop control of blood glucose using the artificial beta cell," Biomedical Engineering, IEEE Transactions on, no. 10, pp. 678-687, 1981.
    • (1981) Biomedical Engineering, IEEE Transactions on , Issue.10 , pp. 678-687
    • Broekhuyse, H.1    Nelson, H.2    Zinman, B.3    Albisser, A.4
  • 3
    • 67650838755 scopus 로고    scopus 로고
    • Impact of shock requiring norepinephrine on the accuracy and reliability of subcutaneous continuous glucose monitoring
    • U. Holzinger, J. Warszawska, R. Kitzberger, H. Herkner, P. Metnitz, and C. Madl, "Impact of shock requiring norepinephrine on the accuracy and reliability of subcutaneous continuous glucose monitoring," Intensive care medicine, vol. 35, no. 8, pp. 1383-1389, 2009.
    • (2009) Intensive Care Medicine , vol.35 , Issue.8 , pp. 1383-1389
    • Holzinger, U.1    Warszawska, J.2    Kitzberger, R.3    Herkner, H.4    Metnitz, P.5    Madl, C.6
  • 4
    • 77957796136 scopus 로고    scopus 로고
    • A comparison of clinical control strategies for the hyperglycemia of injury and illness
    • IEEE
    • M. Borrello, J. Sun, and B. Bequette, "A comparison of clinical control strategies for the hyperglycemia of injury and illness," in American Control Conference (ACC), 2010, pp. 5149-5154, IEEE, 2010.
    • (2010) American Control Conference (ACC) 2010 , pp. 5149-5154
    • Borrello, M.1    Sun, J.2    Bequette, B.3
  • 5
    • 69949146908 scopus 로고    scopus 로고
    • Biosimulation modeling for diabetes: In silico preclinical trials: A proof of concept in closed-loop control of type 1 diabetes
    • B. Kovatchev, M. Breton, C. Dalla Man, and C. Cobelli, "Biosimulation modeling for diabetes: In silico preclinical trials: A proof of concept in closed-loop control of type 1 diabetes," Journal of diabetes science and technology (Online), vol. 3, no. 1, p. 44, 2009.
    • (2009) Journal of Diabetes Science and Technology (Online) , vol.3 , Issue.1 , pp. 44
    • Kovatchev, B.1    Breton, M.2    Dalla Man, C.3    Cobelli, C.4
  • 6
    • 33645051466 scopus 로고    scopus 로고
    • Continuous glucose monitoring and closed-loop systems
    • R. Hovorka, "Continuous glucose monitoring and closed-loop systems," Diabetic Medicine, vol. 23, no. 1, pp. 1-12, 2006.
    • (2006) Diabetic Medicine , vol.23 , Issue.1 , pp. 1-12
    • Hovorka, R.1
  • 9
    • 0028831587 scopus 로고
    • Determinants of blood glucose variability in adolescents with insulin-dependent diabetes mellitus
    • I. Zachrissons, M. Wallensteen, and G. Dahlquist, "Determinants of blood glucose variability in adolescents with insulin-dependent diabetes mellitus," Acta Paediatrica, vol. 84, no. 1, pp. 70-74, 1995.
    • (1995) Acta Paediatrica , vol.84 , Issue.1 , pp. 70-74
    • Zachrissons, I.1    Wallensteen, M.2    Dahlquist, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.