메뉴 건너뛰기




Volumn 19, Issue 1, 2011, Pages 6-11

Sentinel node detection failure due to defective labeling and large particle size of Tc-99m antimony sulfide colloid

Author keywords

Breast cancer; Lymphoscintigraphy; Sentinel node; Tc 99m antimony sulfide colloid

Indexed keywords

ANTIMONY TECHNETIUM SULFIDE TC 99M;

EID: 84855462543     PISSN: 16812824     EISSN: 20082509     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (12)

References (22)
  • 1
    • 68949113489 scopus 로고    scopus 로고
    • Assessment the diagnostic accuracy of sentinel lymph nodes lymphoscintigraphy using Technetium-99m phytate in breast cancer
    • Eftekhari M, Beiki D, Fallahi B, Arabi M, Memari F, Gholamrezanezhad A, et al. Assessment the diagnostic accuracy of sentinel lymph nodes lymphoscintigraphy using Technetium-99m phytate in breast cancer. DARU 2009;17(2):83-87.
    • (2009) DARU , vol.17 , Issue.2 , pp. 83-87
    • Eftekhari, M.1    Beiki, D.2    Fallahi, B.3    Arabi, M.4    Memari, F.5    Gholamrezanezhad, A.6
  • 3
    • 46149092983 scopus 로고    scopus 로고
    • Long-term morbidity of sentinel node biopsy versus complete axillary dissection for unilateral breast cancer
    • Jul
    • Crane-Okada R, Wascher RA, Elashoff D, Giuliano AE. Long-term morbidity of sentinel node biopsy versus complete axillary dissection for unilateral breast cancer. Ann Surg Oncol. 2008 Jul;15(7):1996-2005.
    • (2008) Ann Surg Oncol , vol.15 , Issue.7 , pp. 1996-2005
    • Crane-Okada, R.1    Wascher, R.A.2    Elashoff, D.3    Giuliano, A.E.4
  • 4
    • 55749114055 scopus 로고    scopus 로고
    • Recent advances in sentinel lymph node biopsy for breast cancer
    • Nov
    • Goyal A, Mansel RE. Recent advances in sentinel lymph node biopsy for breast cancer. Curr Opin Oncol. 2008 Nov;20(6):621-6.
    • (2008) Curr Opin Oncol , vol.20 , Issue.6 , pp. 621-626
    • Goyal, A.1    Mansel, R.E.2
  • 6
    • 64949181540 scopus 로고    scopus 로고
    • Comparison of pre-operative lymphoscintigraphy with inter-operative gamma probe and dye technique regarding the number of detected sentinel lymph nodes
    • Jan-Apr
    • Sadeghi R, Forghani MN, Memar B, Abdollahi A, Zakavi SR, Mashhadi MT et al. Comparison of pre-operative lymphoscintigraphy with inter-operative gamma probe and dye technique regarding the number of detected sentinel lymph nodes. Hell J Nucl Med. 2009 Jan-Apr;12(1):30-2.
    • (2009) Hell J Nucl Med , vol.12 , Issue.1 , pp. 30-32
    • Sadeghi, R.1    Forghani, M.N.2    Memar, B.3    Abdollahi, A.4    Zakavi, S.R.5    Mashhadi, M.T.6
  • 7
    • 0033972380 scopus 로고    scopus 로고
    • Radiopharmaceuticals for lymphoscintigraphy: Including dosimetry and radiation considerations
    • Eshima D, Fauconnier T, Eshima L, Thornback JR. Radiopharmaceuticals for lymphoscintigraphy: including dosimetry and radiation considerations. Semin Nucl Med. 2000 Jan;30(1):25-32. (Pubitemid 30059087)
    • (2000) Seminars in Nuclear Medicine , vol.30 , Issue.1 , pp. 25-32
    • Eshima, S.1    Fauconnier, T.2    Eshima, L.3    Thornback, J.R.4
  • 10
    • 16644363657 scopus 로고    scopus 로고
    • Optimal particle size of radiocolloid for sentinel node identification in breast cancer-electron microscopic study and clinical comparison
    • discussion 264-6
    • Sato K, Krag D, Tamaki K, Anzai M, Tsuda H, Kosuda S et al. Optimal particle size of radiocolloid for sentinel node identification in breast cancer-electron microscopic study and clinical comparison. Breast Cancer. 2004;11(3):256-63; discussion 264-6.
    • (2004) Breast Cancer , vol.11 , Issue.3 , pp. 256-263
    • Sato, K.1    Krag, D.2    Tamaki, K.3    Anzai, M.4    Tsuda, H.5    Kosuda, S.6
  • 12
    • 0034740769 scopus 로고    scopus 로고
    • Further optimisation of 99mTc- Nanocoll sentinel node localisation in carcinoma of the breast by improved labelling
    • Oct
    • Gommans GM, van Dongen A, van der Schors TG, Gommans E, Visser JF, Clarijs WW et al. Further optimisation of 99mTc- Nanocoll sentinel node localisation in carcinoma of the breast by improved labelling. Eur J Nucl Med. 2001 Oct;28(10):1450-5.
    • (2001) Eur J Nucl Med , vol.28 , Issue.10 , pp. 1450-1455
    • Gommans, G.M.1    Van Dongen, A.2    Van Der Schors, T.G.3    Gommans, E.4    Visser, J.F.5    Clarijs, W.W.6
  • 14
    • 55149115360 scopus 로고    scopus 로고
    • Influence of temperature on the radiochemical purity of 99mTc-colloidal rhenium sulfide for use in sentinel node localization
    • Nov
    • Bensimhon L, Métayé T, Guilhot J, Perdrisot R. Influence of temperature on the radiochemical purity of 99mTc-colloidal rhenium sulfide for use in sentinel node localization. Nucl Med Commun. 2008 Nov;29(11):1015-20.
    • (2008) Nucl Med Commun , vol.29 , Issue.11 , pp. 1015-1020
    • Bensimhon, L.1    Métayé, T.2    Guilhot, J.3    Perdrisot, R.4
  • 15
    • 68949086878 scopus 로고    scopus 로고
    • Production of 99mTc-Antimony sulfide colloid for lymphoscintigraphy
    • Shabani GA, Hamzeh H, Najafi R. Production of 99mTc-Antimony sulfide colloid for lymphoscintigraphy. Iran J Nucl Med. 2003;19:57-65.
    • (2003) Iran J Nucl Med , vol.19 , pp. 57-65
    • Shabani, G.A.1    Hamzeh, H.2    Najafi, R.3
  • 16
    • 77349110016 scopus 로고    scopus 로고
    • Factors affecting sentinel lymph node detection failure in breast cancer patients using intradermal injection of the tracer
    • Mar- Apr
    • Abdollahi A, Jangjoo A, Dabbagh Kakhki VR, Rasoul Zakavi S, Memar B, Naser Forghani M et al. Factors affecting sentinel lymph node detection failure in breast cancer patients using intradermal injection of the tracer. Rev Esp Med Nucl. 2010 Mar- Apr;29(2):73-7.
    • (2010) Rev Esp Med Nucl , vol.29 , Issue.2 , pp. 73-77
    • Abdollahi, A.1    Jangjoo, A.2    Dabbagh Kakhki, V.R.3    Rasoul Zakavi, S.4    Memar, B.5    Naser Forghani, M.6
  • 20
    • 79955008484 scopus 로고    scopus 로고
    • Disappearance of a sentinel node on the delayed lymphoscintigraphy imaging of a breast cancer patient: Importance of blue dye injection
    • Jangjoo A, Shabani GA, Zakavi R, Dabbagh Kakhki VR, Sadeghi R. Disappearance of a sentinel node on the delayed lymphoscintigraphy imaging of a breast cancer patient: Importance of blue dye injection. NOWOTWORY J Oncol. 2011;61(1):30-31.
    • (2011) NOWOTWORY J Oncol , vol.61 , Issue.1 , pp. 30-31
    • Jangjoo, A.1    Shabani, G.A.2    Zakavi, R.3    Dabbagh Kakhki, V.R.4    Sadeghi, R.5
  • 21
    • 33748112752 scopus 로고    scopus 로고
    • New technology of technetium-99 labeled antimony trisulfide colloid intended for sentinel lymph node imaging
    • DOI 10.1007/s11094-006-0081-z
    • Qaiser Shah S. New technology of technetium-99 labeled antimony trisulfide colloid intended for sentinel lymph node imaging. Pharm Chem J. 2006;40(3):151-154. (Pubitemid 44306159)
    • (2006) Pharmaceutical Chemistry Journal , vol.40 , Issue.3 , pp. 151-154
    • Qaiser, S.S.1
  • 22
    • 84855431228 scopus 로고    scopus 로고
    • Sentinel node biopsy in medical practice: More than 6 years of practice in Mashhad
    • Sadeghi R. Sentinel node biopsy in medical practice: more than 6 years of practice in Mashhad. Iran J Nucl Med. 2010;18(Suppl 1):56.
    • (2010) Iran J Nucl Med , vol.18 , Issue.SUPPL. 1 , pp. 56
    • Sadeghi, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.