메뉴 건너뛰기




Volumn 39, Issue 1, 2012, Pages 246-256

Characterization of ultrasound elevation beamwidth artifacts for prostate brachytherapy needle insertion

Author keywords

brachytherapy; localization error; main lobe; side lobe; ultrasound imaging

Indexed keywords

ERRORS; ONCOLOGY; RADIOTHERAPY; ULTRASONIC IMAGING; UROLOGY;

EID: 84855429667     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3669488     Document Type: Article
Times cited : (20)

References (27)
  • 2
    • 0033011693 scopus 로고    scopus 로고
    • American brachytherapy society recommendations for transperineal permanent brachytherapy of the prostate cancer
    • 10.1016/S0360-3016(98)00452-0
    • S. Nag, D. Beyer, J. Friedland, P. Grimm, and R. Nath, American brachytherapy society recommendations for transperineal permanent brachytherapy of the prostate cancer., Int. J. Radiat. Oncol., Biol., Phys. 44, 789-799 (1999). 10.1016/S0360-3016(98)00452-0
    • (1999) Int. J. Radiat. Oncol., Biol., Phys. , vol.44 , pp. 789-799
    • Nag, S.1    Beyer, D.2    Friedland, J.3    Grimm, P.4    Nath, R.5
  • 3
    • 26844533463 scopus 로고    scopus 로고
    • Prostate brachytherapy: A review of current practice
    • 10.1017/S1460396905000130
    • P. Bownes and A. Flynn, Prostate brachytherapy: A review of current practice., J. Radiother. Pract. 4, 86-101 (2004). 10.1017/S1460396905000130
    • (2004) J. Radiother. Pract. , vol.4 , pp. 86-101
    • Bownes, P.1    Flynn, A.2
  • 4
    • 0019417880 scopus 로고
    • Slice thickness artifacts in gray-scale ultrasound
    • 10.1002/jcu.v9:7
    • A. Goldstein and B. L. Madrazo, Slice thickness artifacts in gray-scale ultrasound., J. Clin. Ultrasound 9, 365-375 (1981). 10.1002/jcu.v9:7
    • (1981) J. Clin. Ultrasound , vol.9 , pp. 365-375
    • Goldstein, A.1    Madrazo, B.L.2
  • 5
    • 17844390697 scopus 로고    scopus 로고
    • Brachytherapy needle deflection evaluation and correction
    • 10.1118/1.1871372
    • G. Wan, Z. Wei, L. Gardi, D. B. Downey, and A. Fenster, Brachytherapy needle deflection evaluation and correction., Med. Phys. 32, 902-909 (2005). 10.1118/1.1871372
    • (2005) Med. Phys. , vol.32 , pp. 902-909
    • Wan, G.1    Wei, Z.2    Gardi, L.3    Downey, D.B.4    Fenster, A.5
  • 10
    • 0020390696 scopus 로고
    • The importance of ultrasonic side-lobe artifacts
    • F. C. Liang and A. B. Kurtz, The importance of ultrasonic side-lobe artifacts., Radiology 145, 763-768 (1982).
    • (1982) Radiology , vol.145 , pp. 763-768
    • Liang, F.C.1    Kurtz, A.B.2
  • 13
    • 0025773218 scopus 로고
    • Sonographic artifacts and their origins
    • K. A. Scanlan, Sonographic artifacts and their origins., Am. J. Roentgenol. 156, 1267-1272 (1991).
    • (1991) Am. J. Roentgenol. , vol.156 , pp. 1267-1272
    • Scanlan, K.A.1
  • 14
    • 0032905291 scopus 로고    scopus 로고
    • Test object for measurement of section thickness at ultrasound
    • B. Richard, Test object for measurement of section thickness at ultrasound., Radiology 221, 279-282 (1999).
    • (1999) Radiology , vol.221 , pp. 279-282
    • Richard, B.1
  • 15
    • 0025875681 scopus 로고
    • Estimation of beam width in the elevation (section thickness) plane
    • M. L. Skolnick, Estimation of beam width in the elevation (section thickness) plane., Radiology 108, 286-288 (1991).
    • (1991) Radiology , vol.108 , pp. 286-288
    • Skolnick, M.L.1
  • 16
    • 0031230885 scopus 로고    scopus 로고
    • Side lobes and grating lobes artifacts in ultrasound imaging
    • 10.1111/j.1740-8261.1997.tb02104.x
    • P. Y. Barthez, R. Leveille, and P. V. Scrivani, Side lobes and grating lobes artifacts in ultrasound imaging., Radiol. Ultrasound 38, 387-393 (1997). 10.1111/j.1740-8261.1997.tb02104.x
    • (1997) Radiol. Ultrasound , vol.38 , pp. 387-393
    • Barthez, P.Y.1    Leveille, R.2    Scrivani, P.V.3
  • 17
    • 34548081119 scopus 로고    scopus 로고
    • Adoptive beamforming applied to medical ultrasound imaging
    • 10.1109/TUFFC.2007.431
    • J. F. Synnevag, A. Austeng, and S. Holm, Adoptive beamforming applied to medical ultrasound imaging., IEEE Trans. Ultrason. Ferroelectr. Freq. Control 54 (8), 1606-1613 (2007). 10.1109/TUFFC.2007.431
    • (2007) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.54 , Issue.8 , pp. 1606-1613
    • Synnevag, J.F.1    Austeng, A.2    Holm, S.3
  • 18
    • 33846888957 scopus 로고    scopus 로고
    • Minimum variance adaptive beamforming applied to medical ultrasound imaging
    • (IEEE-INST Electronical Electronic Engineers Inc., Piscataway, NJ)
    • J. F. Synnevag and A. Austeng, Minimum variance adaptive beamforming applied to medical ultrasound imaging., Proc. IEEE Ultrason. Symp. (IEEE-INST Electronical Electronic Engineers Inc., Piscataway, NJ, 2005), pp. 1199-1202.
    • (2005) Proc. IEEE Ultrason. Symp. , pp. 1199-1202
    • Synnevag, J.F.1    Austeng, A.2
  • 19
    • 78149236522 scopus 로고    scopus 로고
    • Eigenspace-based minimum variance beamforming applied to medical ultrasound imaging
    • 10.1109/TUFFC.2010.1706
    • B. Mohammadzadeh Asl, and A. Mahloojifar, Eigenspace-based minimum variance beamforming applied to medical ultrasound imaging., IEEE Trans. Ultrason. Ferroelectr. Freq. Control 57 (11), 2381-2390 (2010). 10.1109/TUFFC.2010.1706
    • (2010) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.57 , Issue.11 , pp. 2381-2390
    • Mohammadzadeh Asl, B.1    Mahloojifar, A.2
  • 20
    • 0036992283 scopus 로고    scopus 로고
    • A constrained adaptive beamformer for medical ultrasound: Initial results
    • 10.1109/ULTSYM.2002.1192650
    • J. A. Mann and W. F. Walker, A constrained adaptive beamformer for medical ultrasound: Initial results., Proc. IEEE Ultrason. Symp. 2, 1807-1810 (2002). 10.1109/ULTSYM.2002.1192650
    • (2002) Proc. IEEE Ultrason. Symp. , vol.2 , pp. 1807-1810
    • Mann, J.A.1    Walker, W.F.2
  • 21
    • 26844536084 scopus 로고    scopus 로고
    • Time-delay- and timereversal-based robust Capon beamformers for ultrasound imaging
    • 10.1109/TMI.2005.857222
    • Z. Wang, J. Li, and R. Wu, Time-delay- and timereversal-based robust Capon beamformers for ultrasound imaging., IEEE Trans. Med. Imaging 24, 1308-1322 (2005). 10.1109/TMI.2005.857222
    • (2005) IEEE Trans. Med. Imaging , vol.24 , pp. 1308-1322
    • Wang, Z.1    Li, J.2    Wu, R.3
  • 22
    • 68149099887 scopus 로고    scopus 로고
    • Imaging of implant needles for real-time HDR-brachytherapy prostate treatment using biplane ultrasound transducers
    • 10.1118/1.3157107
    • F. A. Siebert, Imaging of implant needles for real-time HDR-brachytherapy prostate treatment using biplane ultrasound transducers., Med. Phys. 36, 3406-3412 (2009). 10.1118/1.3157107
    • (2009) Med. Phys. , vol.36 , pp. 3406-3412
    • Siebert, F.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.