Volumn 58, Issue 1, 2012, Pages 25-31

In vitro study of the norwood palliation: A patient-specific mock circulatory system

(20)  Biglino, Giovanni a   Giardini, Alessandro a,d   Baker, Catriona a   Figliola, Richard S b   Hsia, Tain Yen a   Taylor, Andrew M a,d   Schievano, Silvia a,d   Bove, Edward c   Dorfman, Adam c   Khambadkone, Sachin d   De Leval, Marc d   Hsia, T Y d   Baker, G Hamilton e   Hlavacek, Anthony e   Migliavacca, Francesco f   Pennati, Giancarlo f   Dubini, Gabriele f   McGregor, John b   Marsden, Alison g   Vignon Clementel, Irene h  


Author keywords

[No Author keywords available]

Indexed keywords

AORTIC ARCH; AORTIC COARCTATION; EFFECT OF PRESSURE; IN-VITRO; INSTANTANEOUS FLOW MEASUREMENTS; LOWER BODY; MAGNETIC RESONANCE IMAGES; MOCK CIRCULATION; MOCK CIRCULATORY SYSTEMS; MULTISCALES; PRESSURE SIGNAL; THORACIC AORTA; THREE-DIMENSIONAL (3D); VOLUME DISTRIBUTIONS;

EID: 84855409417     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/MAT.0b013e3182396847     Document Type: Article
Times cited : (27)

References (24)
  • 2
    • 0025835172 scopus 로고
    • Hypoplastic left heart syndrome
    • Norwood WI Jr: Hypoplastic left heart syndrome. Ann Thorac Surg 52: 688-695, 1991.
    • (1991) Ann Thorac Surg , vol.52 , pp. 688-695
    • Norwood Jr., W.I.1
  • 3
    • 0042856648 scopus 로고    scopus 로고
    • Right ventricle-pulmonary artery shunt in first-stage palliation of hypoplastic left heart syndrome
    • discussion 509
    • Sano S, Ishino K, Kawada M, et al: Right ventricle-pulmonary artery shunt in first-stage palliation of hypoplastic left heart syndrome. J Thorac Cardiovasc Surg 126: 504-509; discussion 509, 2003.
    • (2003) J Thorac Cardiovasc Surg , vol.126 , pp. 504-509
    • Sano, S.1    Ishino, K.2    Kawada, M.3
  • 4
    • 77952760954 scopus 로고    scopus 로고
    • Comparison of shunt types in the Norwood procedure for single-ventricle lesions
    • Ohye RG, Sleeper LA, Mahony L, et al; Pediatric Heart Network Investigators: Comparison of shunt types in the Norwood procedure for single-ventricle lesions. N Engl J Med 362: 1980-1992, 2010.
    • (2010) N Engl J Med , vol.362 , pp. 1980-1992
    • Ohye, R.G.1    Sleeper, L.A.2    Mahony, L.3
  • 5
    • 0035039163 scopus 로고    scopus 로고
    • Modeling of the Norwood circulation: Effects of shunt size, vascular resistances, and heart rate
    • Migliavacca F, Pennati G, Dubini G, et al: Modeling of the Norwood circulation: Effects of shunt size, vascular resistances, and heart rate. Am J Physiol Heart Circ Physiol 280: H2076-H2086, 2001.
    • (2001) Am J Physiol Heart Circ Physiol , vol.280
    • Migliavacca, F.1    Pennati, G.2    Dubini, G.3
  • 6
    • 85006589834 scopus 로고    scopus 로고
    • Analysis of a geometrical multiscale model based on the coupling of PDEs and ODEs for blood flow simulations
    • Quarteroni A, Veneziani A: Analysis of a geometrical multiscale model based on the coupling of PDEs and ODEs for blood flow simulations. Multiscale Model Simul SIAM Interdiscipli J 1:173-195, 2003.
    • (2003) Multiscale Model Simul SIAM Interdiscipli J , vol.1 , pp. 173-195
    • Quarteroni, A.1    Veneziani, A.2
  • 7
    • 33645068602 scopus 로고    scopus 로고
    • Multiscale modelling in biofluidynamics: Application to reconstructive paediatric cardiac surgery
    • Migliavacca F, Balossino R, Pennati G, et al: Multiscale modelling in biofluidynamics: Application to reconstructive paediatric cardiac surgery. J Biomech 39: 1010-1020, 2006.
    • (2006) J Biomech , vol.39 , pp. 1010-1020
    • Migliavacca, F.1    Balossino, R.2    Pennati, G.3
  • 8
    • 0034665965 scopus 로고    scopus 로고
    • Coarctation index: Identification of recurrent coarctation in infants with hypoplastic left heart syndrome after the Norwood procedure
    • Lemler MS, Zellers TM, Harris KA, Ramaciotti C: Coarctation index: Identification of recurrent coarctation in infants with hypoplastic left heart syndrome after the Norwood procedure. Am J Cardiol 86: 697-9, A9, 2000.
    • (2000) Am J Cardiol , vol.86 , pp. 697-9
    • Lemler, M.S.1    Zellers, T.M.2    Harris, K.A.3    Ramaciotti, C.4
  • 10
    • 79953179012 scopus 로고    scopus 로고
    • Hydrodynamic evaluation of a bioreactor for tissue engineering heart valves
    • Bowles C, New S, van Loon R, et al: Hydrodynamic evaluation of a bioreactor for tissue engineering heart valves. Cardiovasc Eng Technol 1:10-17, 2010.
    • (2010) Cardiovasc Eng Technol , vol.1 , pp. 10-17
    • Bowles, C.1    New, S.2    Van Loon, R.3
  • 11
    • 84857980483 scopus 로고    scopus 로고
    • A mock circulatory system with physiological distribution of terminal resistance and compliance: Application for testing the intra-aortic balloon pump
    • doi 10.1111/j.1525-1594.2010.01071.x. [Epub ahead of print]
    • Kolyva C Biglino G, Pepper JR, Khir AW: A mock circulatory system with physiological distribution of terminal resistance and compliance: Application for testing the intra-aortic balloon pump Artif Organs: 2010. doi: 10.1111/j.1525-1594.2010.01071.x. [Epub ahead of print].
    • (2010) Artif Organs
    • Kolyva, C.1    Biglino, G.2    Pepper, J.R.3    Khir, A.W.4
  • 12
    • 0036252346 scopus 로고    scopus 로고
    • Arterial compliance is a main variable determining the effectiveness of intra-aortic balloon counterpulsation: Quantitative data from an in vitro study
    • DOI 10.1016/S1350-4533(02)00013-9, PII S1350453302000139
    • Papaioannou TG, Mathioulakis DS, Nanas JN, Tsangaris SG, Stamatelopoulos SF, Moulopoulos SD: Arterial compliance is a main variable determining the effectiveness of intra-aortic balloon counterpulsation: Quantitative data from an in vitro study. Med Eng Phys 24: 279-284, 2002. (Pubitemid 34499546)
    • (2002) Medical Engineering and Physics , vol.24 , Issue.4 , pp. 279-284
    • Papaioannou, T.G.1    Mathioulakis, D.S.2    Nanas, J.N.3    Tsangaris, S.G.4    Stamatelopoulos, S.F.5    Moulopoulos, S.D.6
  • 13
    • 9244231824 scopus 로고    scopus 로고
    • A model for educational simulation of infant cardiovascular physiology
    • DOI 10.1213/01.ANE.0000134797.52793.AF
    • Goodwin JA, van Meurs WL, Sá Couto CD, Beneken JE, Graves SA: A model for educational simulation of infant cardiovascular physiology. Anesth Analg 99: 1655-1664, table of contents, 2004. (Pubitemid 39551898)
    • (2004) Anesthesia and Analgesia , vol.99 , Issue.6 , pp. 1655-1664
    • Goodwin, J.A.1    Van Meurs, W.L.2    Sa Couto, C.D.3    Beneken, J.E.W.4    Graves, S.A.5
  • 14
    • 62849083921 scopus 로고    scopus 로고
    • Corrected and improved model for educational simulation of neonatal cardiovascular pathophysiology
    • Zijlmans M, Sá-Couto CD, van Meurs WL, Goodwin JA, Andriessen P: Corrected and improved model for educational simulation of neonatal cardiovascular pathophysiology. Simul Healthc 4: 49-53, 2009.
    • (2009) Simul Healthc , vol.4 , pp. 49-53
    • Zijlmans, M.1    Sá-Couto, C.D.2    Van Meurs, W.L.3    Goodwin, J.A.4    Andriessen, P.5
  • 17
    • 1642394754 scopus 로고    scopus 로고
    • In vitro assessment of the unloading and perfusion capacities of the PUCA II and the IABP
    • DOI 10.1191/0267659104pf710oa
    • Vandenberghe S, Segers P, Josemans H, Van Loon JP, Rakhorst G, Verdonck P: In vitro assessment of the unloading and perfusion capacities of the PUCA II and the IABP. Perfusion 19: 25-32, 2004. (Pubitemid 38386646)
    • (2004) Perfusion , vol.19 , Issue.1 , pp. 25-32
    • Vandenberghe, S.1    Segers, P.2    Josemans, H.3    Van Loon, J.-P.4    Rakhorst, G.5    Verdonck, P.6
  • 18
    • 0017063809 scopus 로고
    • The fluid mechanics of aortic stenosis-I Theory and steady flow experiments
    • Clark C: The fluid mechanics of aortic stenosis-I. Theory and steady flow experiments. J Biomech 9: 521-528, 1976.
    • (1976) J Biomech , vol.9 , pp. 521-528
    • Clark, C.1
  • 19
    • 0018730254 scopus 로고
    • Energy losses in flow through stenosed valves
    • DOI 10.1016/0021-9290(79)90159-3
    • Clark C: Energy losses in flow through stenosed valves. J Biomech 12: 737-746, 1979. (Pubitemid 10248086)
    • (1979) Journal of Biomechanics , vol.12 , Issue.10 , pp. 737-746
    • Clark, C.1
  • 20
    • 76449119396 scopus 로고    scopus 로고
    • Pressure recovery explains doppler overestimation of invasive pressure gradient across segmental vascular stenosis
    • Giardini A, Tacy TA: Pressure recovery explains doppler overestimation of invasive pressure gradient across segmental vascular stenosis. Echocardiography 27: 21-31, 2010.
    • (2010) Echocardiography , vol.27 , pp. 21-31
    • Giardini, A.1    Tacy, T.A.2
  • 22
    • 5144223967 scopus 로고    scopus 로고
    • How important is the impact of pressure recovery on routine evaluation of aortic stenosis? A clinical study in 91 patients
    • Isaaz K, Gaillard O, Cerisier A, et al: How important is the impact of pressure recovery on routine evaluation of aortic stenosis? A clinical study in 91 patients. J Heart Valve Dis 13: 347-356, 2004.
    • (2004) J Heart Valve Dis , vol.13 , pp. 347-356
    • Isaaz, K.1    Gaillard, O.2    Cerisier, A.3
  • 23
    • 0028040218 scopus 로고
    • Pressure recovery in aortic valve stenosis
    • Laskey WK, Kussmaul WG: Pressure recovery in aortic valve stenosis. Circulation 89: 116-121, 1994. (Pubitemid 24026480)
    • (1994) Circulation , vol.89 , Issue.1 , pp. 116-121
    • Laskey, W.K.1    Kussmaul, W.G.2
  • 24
    • 84855411760 scopus 로고    scopus 로고
    • Quantification of TangoPlus FullCure® 930 compliance for printing patient-specific vascular models
    • Biglino G, Verschueren P, Zegels R, Taylor AM, Schievano S: Quantification of TangoPlus FullCure® 930 compliance for printing patient-specific vascular models. ASAIO J 57: 74, 2011.
    • (2011) ASAIO J , vol.57 , pp. 74
    • Biglino, G.1    Verschueren, P.2    Zegels, R.3    Taylor, A.M.4    Schievano, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.