메뉴 건너뛰기




Volumn 5, Issue 6, 2011, Pages 568-578

A novel low-power-implantable epileptic seizure-onset detector

Author keywords

Algorithm; Epilepsy; Low noise; Low power; Microelectronics; Seizure detector

Indexed keywords

ANALOG DOMAIN; CLINICAL MANIFESTATION; DIGITAL DEMODULATORS; DIGITAL DOMAIN; EPILEPSY; EPILEPTIC SEIZURE DETECTION; HIGH FREQUENCY HF; LOW FREQUENCY; LOW NOISE; LOW POWER; RIPPLE NOISE; SEIZURE DETECTION; TOTAL POWER CONSUMPTION; ULTRA-LOW POWER;

EID: 84855357985     PISSN: 19324545     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBCAS.2011.2157153     Document Type: Conference Paper
Times cited : (69)

References (27)
  • 2
    • 75749112162 scopus 로고    scopus 로고
    • Summit Contributors, advances in the application of technology to epilepsy: The CIMIT/NIO epilepsy innovation summit
    • S. C. Schachter, J. Guttag, S. J. Schiff, and D. L. Schomer, "Summit Contributors, advances in the application of technology to epilepsy: The CIMIT/NIO epilepsy innovation summit," Epilep. Behav., vol. 16, pp. 3-46, 2009.
    • (2009) Epilep. Behav. , vol.16 , pp. 3-46
    • Schachter, S.C.1    Guttag, J.2    Schiff, S.J.3    Schomer, D.L.4
  • 3
    • 79952385304 scopus 로고    scopus 로고
    • Low-power implantable device for onset detection and subsequent treatment of epileptic seizures: A review
    • M. T. Salam, M. Sawan, and D. K. Nguyen, "Low-power implantable device for onset detection and subsequent treatment of epileptic seizures: A review," J. Healthcare Eng., vol. 1, no. 2, pp. 169-184, 2010.
    • (2010) J. Healthcare Eng. , vol.1 , Issue.2 , pp. 169-184
    • Salam, M.T.1    Sawan, M.2    Nguyen, D.K.3
  • 4
    • 77951546450 scopus 로고    scopus 로고
    • Electrical stimulation of the anterior nucleus of thalamus for treatment of refractory epilepsy
    • R. Fisher, V. Salanova, T. Witt, R. Worth, T. Henry, R. Gross, K. Oommen, and I. Osorio et al., "Electrical stimulation of the anterior nucleus of thalamus for treatment of refractory epilepsy," Epilepsia, vol. 51, no. 5, pp. 899-908, 2010.
    • (2010) Epilepsia , vol.51 , Issue.5 , pp. 899-908
    • Fisher, R.1    Salanova, V.2    Witt, T.3    Worth, R.4    Henry, T.5    Gross, R.6    Oommen, K.7    Osorio, I.8
  • 6
    • 70350247742 scopus 로고    scopus 로고
    • Pharmaco-resistant seizures: Self-triggering capacity, scale-free properties and predictability
    • I. Osorio, M. G. Frei, D. Sornette, and J. Milton, "Pharmaco- resistant seizures: Self-triggering capacity, scale-free properties and predictability," Eur. J. Neurosci., vol. 30, pp. 1554-1558, 2009.
    • (2009) Eur. J. Neurosci. , vol.30 , pp. 1554-1558
    • Osorio, I.1    Frei, M.G.2    Sornette, D.3    Milton, J.4
  • 7
    • 70350620967 scopus 로고    scopus 로고
    • Real-time detection, quantification, warning, and control of epileptic seizures: The foundations for a scientific epileptology
    • I. Osorio and M. G. Frei, "Real-time detection, quantification, warning, and control of epileptic seizures: The foundations for a scientific epileptology," Epilep. Behav., vol. 16, pp. 391-396, 2009.
    • (2009) Epilep. Behav. , vol.16 , pp. 391-396
    • Osorio, I.1    Frei, M.G.2
  • 8
    • 78650846313 scopus 로고    scopus 로고
    • Epileptic seizure onset detection prior to clinical manifestation
    • Buenos Aires, Argentina
    • M. T. Salam, M. Sawan, and D. K. Nguyen, "Epileptic seizure onset detection prior to clinical manifestation," in Proc. IEEEEMBC, Buenos Aires, Argentina, 2010, p. 6210-3.
    • (2010) Proc. IEEEEMBC , pp. 6210-3
    • Salam, M.T.1    Sawan, M.2    Nguyen, D.K.3
  • 9
    • 77749315839 scopus 로고    scopus 로고
    • Epileptic low-voltage fast-activity seizure-onset detector
    • M. T. Salam, M. Sawan, D. K. Nguyen, and A. A. Hamoui, "Epileptic low-voltage fast-activity seizure-onset detector," in Proc. IEEE-BIOCAS, 2009, pp. 169-172.
    • (2009) Proc. IEEE-BIOCAS , pp. 169-172
    • Salam, M.T.1    Sawan, M.2    Nguyen, D.K.3    Hamoui, A.A.4
  • 10
  • 11
    • 77952959080 scopus 로고    scopus 로고
    • Linear-phase delay filters for ultra-low-power signal processing in neural recording implants
    • Jun.
    • B. Gosselin, M. Sawan, and E. Kerherv, "Linear-phase delay filters for ultra-low-power signal processing in neural recording implants," IEEE Trans. Biomed. Circuits Syst., vol. 4, no. 3, pp. 171-180, Jun. 2010.
    • (2010) IEEE Trans. Biomed. Circuits Syst. , vol.4 , Issue.3 , pp. 171-180
    • Gosselin, B.1    Sawan, M.2    Kerherv, E.3
  • 12
    • 77953620781 scopus 로고    scopus 로고
    • A low-power integrated neural interface with digital spike detection and extraction
    • B. Gosselin and M. Sawan, "A low-power integrated neural interface with digital spike detection and extraction," Analog Integr. Circuits Signal Process., vol. 64, no. 1, pp. 3-11, 2010.
    • (2010) Analog Integr. Circuits Signal Process. , vol.64 , Issue.1 , pp. 3-11
    • Gosselin, B.1    Sawan, M.2
  • 13
    • 69249141469 scopus 로고    scopus 로고
    • An ultra low-power CMOS automatic action potential detector
    • Aug.
    • B. Gosselin and M. Sawan, "An ultra low-power CMOS automatic action potential detector," IEEE Trans. Neural Syst. Rehab. Eng., vol. 17, no. 4, pp. 346-353, Aug. 2009.
    • (2009) IEEE Trans. Neural Syst. Rehab. Eng. , vol.17 , Issue.4 , pp. 346-353
    • Gosselin, B.1    Sawan, M.2
  • 14
    • 39549086320 scopus 로고    scopus 로고
    • A low-power integrated bioamplifier with active low-frequency suppression
    • DOI 10.1109/TBCAS.2007.914490
    • B. Gosselin, M. Sawan, and C. A. Chapman, "A low-power integrated bioamplifier with active low-frequency suppression," IEEE Trans. Biomed. Circuits Syst., vol. 1, no. 3, pp. 184-192, Sep. 2007. (Pubitemid 351279737)
    • (2007) IEEE Transactions on Biomedical Circuits and Systems , vol.1 , Issue.3 , pp. 184-192
    • Gosselin, B.1    Sawan, M.2    Chapman, C.A.3
  • 15
    • 4944259867 scopus 로고    scopus 로고
    • An ultra low-power chopper stabilized front-end for multichannel cortical signals recording
    • B. Gosselin, V. Simard, and M. Sawan, "An ultra low-power chopper stabilized front-end for multichannel cortical signals recording," in Proc. IEEE CCECE, 2004, pp. 2259-2262.
    • (2004) Proc. IEEE CCECE , pp. 2259-2262
    • Gosselin, B.1    Simard, V.2    Sawan, M.3
  • 16
    • 77951117508 scopus 로고    scopus 로고
    • Epileptic seizures detection using continuous time wavelet based artificial neural networks
    • A. Berdakh and S. H. Don, "Epileptic seizures detection using continuous time wavelet based artificial neural networks," in Proc. Int. Conf. Inf. Technol.: New Generation, 2009, pp. 1456-1461.
    • (2009) Proc. Int. Conf. Inf. Technol.: New Generation , pp. 1456-1461
    • Berdakh, A.1    Don, S.H.2
  • 19
    • 24644496662 scopus 로고    scopus 로고
    • An automatic warning system for epileptic seizures recorded on intracerebral EEGs
    • G. Sukhi and G. Jean, "An automatic warning system for epileptic seizures recorded on intracerebral EEGs," Clin. Neurophysiol., vol. 116, pp. 2460-2472, 2005.
    • (2005) Clin. Neurophysiol. , vol.116 , pp. 2460-2472
    • Sukhi, G.1    Jean, G.2
  • 20
    • 77950986511 scopus 로고    scopus 로고
    • A new improved modelbased seizure detection using statistically optimal null filter
    • R. Yadav, R. Agarwal, and M. N. S. Swamy, "A new improved modelbased seizure detection using statistically optimal null filter," Proc. IEEE-Eng. Med. Biol. Conf., pp. 1318-1322, 2009.
    • (2009) Proc. IEEE-Eng. Med. Biol. Conf. , pp. 1318-1322
    • Yadav, R.1    Agarwal, R.2    Swamy, M.N.S.3
  • 21
    • 77957686139 scopus 로고    scopus 로고
    • The design and hardware implementation of a low-power real-time seizure detection algorithm
    • Oct.
    • S. Raghunathan, S. K. Gupta, M. P.Ward, R. M.Worth, K. Roy, and P. P. Irazoqui, "The design and hardware implementation of a low-power real-time seizure detection algorithm," J. Neural Eng., vol. 6, no. 5, pp. 056005 (13)-056005 (13), Oct. 2009.
    • (2009) J. Neural Eng. , vol.6 , Issue.5 , pp. 05600513-05600513
    • Raghunathan, S.1    Gupta, S.K.2    Ward, M.P.3    Worth, R.M.4    Roy, K.5    Irazoqui, P.P.6
  • 22
    • 77950193145 scopus 로고    scopus 로고
    • A micro-Power EEG acquisition SoC with integrated feature extraction processor for a chronic seizure detection system
    • Apr.
    • N. Verma, A. Shoeb, J. Bohorquez, J. Dawson, J. Guttag, and A. P. Chandrakasan, "A micro-Power EEG acquisition SoC with integrated feature extraction processor for a chronic seizure detection system," IEEE J. Solid-State Circuits, vol. 45, no. 4, pp. 804-816, Apr. 2010.
    • (2010) IEEE J. Solid-State Circuits , vol.45 , Issue.4 , pp. 804-816
    • Verma, N.1    Shoeb, A.2    Bohorquez, J.3    Dawson, J.4    Guttag, J.5    Chandrakasan, A.P.6
  • 24
    • 31544473492 scopus 로고    scopus 로고
    • Analog seizure detection and performance evaluation
    • DOI 10.1109/TBME.2005.862532
    • N. C. Bhavaraju, M. G. Frei, and I. Osorio, "Analog seizure detection and performance evaluation," IEEE Trans. Biomed. Eng., vol. 53, no. 2, pp. 238-245, Feb. 2006. (Pubitemid 43162412)
    • (2006) IEEE Transactions on Biomedical Engineering , vol.53 , Issue.2 , pp. 238-245
    • Bhavaraju, N.C.1    Frei, M.G.2    Osorio, I.3
  • 27
    • 3543111356 scopus 로고    scopus 로고
    • "The CMOS inverter" as a comparator in ADC designs
    • A. Tangel and K. Choi, ""The CMOS inverter" as a comparator in ADC designs," Analog Integr. Circuits Signal Process., vol. 39, pp. 55-147, 2004.
    • (2004) Analog Integr. Circuits Signal Process. , vol.39 , pp. 55-147
    • Tangel, A.1    Choi, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.