메뉴 건너뛰기




Volumn 176, Issue 1-2, 2012, Pages 229-234

A novel pH sensing membrane based on an ionic liquid-polymer composite

Author keywords

Ionic liquid; pH; Plasticizer; Quinhydrone

Indexed keywords


EID: 84855355269     PISSN: 00263672     EISSN: 14365073     Source Type: Journal    
DOI: 10.1007/s00604-011-0723-z     Document Type: Article
Times cited : (14)

References (28)
  • 2
    • 39749168341 scopus 로고    scopus 로고
    • Review on state-of-the-art in polymer based pH sensors
    • Korostynska O, Arshak K, Gill E, Arshak (2007) Review on state-of-the-art in polymer based pH sensors. Sensors 7: 3027-3042.
    • (2007) Sensors , vol.7 , pp. 3027-3042
    • Korostynska, O.1    Arshak, K.2    Gill, E.3    Arshak4
  • 4
    • 28644439681 scopus 로고    scopus 로고
    • pH-Sensitive solid-state electrode based on electrodeposited nanoporous platinum
    • Sejin P, Hankil B, Yunmee K, Ji-Hyung H, Hee CK, Taek DC (2005) pH-Sensitive solid-state electrode based on electrodeposited nanoporous platinum. Anal Chem 77: 7695-7701.
    • (2005) Anal Chem , vol.77 , pp. 7695-7701
    • Sejin, P.1    Hankil, B.2    Yunmee, K.3    Ji-Hyung, H.4    Hee, C.K.5    Taek, D.C.6
  • 6
    • 54249132624 scopus 로고    scopus 로고
    • Solid-contact ionophore-based electrode for determination of pH in acidic media
    • Samsonova EN, Lutov VM, Mikhelson KN (2009) Solid-contact ionophore-based electrode for determination of pH in acidic media. J Solid State Electrochem 13: 69-75.
    • (2009) J Solid State Electrochem , vol.13 , pp. 69-75
    • Samsonova, E.N.1    Lutov, V.M.2    Mikhelson, K.N.3
  • 7
    • 77049119919 scopus 로고    scopus 로고
    • Photocurable pH-sensitive membrane for ion-selective field effect transistors
    • Abramova N, Bratov A (2010) Photocurable pH-sensitive membrane for ion-selective field effect transistors. Talanta 81: 208-212.
    • (2010) Talanta , vol.81 , pp. 208-212
    • Abramova, N.1    Bratov, A.2
  • 8
    • 56249140392 scopus 로고    scopus 로고
    • A novel pH sensor based on hydroquinone monosulfonate-doped conducting polypyrrole
    • Prissanaroon-Ouajai W, Pigram PJ, Jones R, Sirivat A (2008) A novel pH sensor based on hydroquinone monosulfonate-doped conducting polypyrrole. Sens Actuators B Chem 135: 366-374.
    • (2008) Sens Actuators B Chem , vol.135 , pp. 366-374
    • Prissanaroon-Ouajai, W.1    Pigram, P.J.2    Jones, R.3    Sirivat, A.4
  • 9
    • 11444265539 scopus 로고    scopus 로고
    • A new calibration free pH-probe for in situ measurements of soil pH
    • Kahlert H, Steinhardt T, Behnert J, Scholz F (2004) A new calibration free pH-probe for in situ measurements of soil pH. Electroanalysis 16: 2058-2064.
    • (2004) Electroanalysis , vol.16 , pp. 2058-2064
    • Kahlert, H.1    Steinhardt, T.2    Behnert, J.3    Scholz, F.4
  • 10
    • 0035930661 scopus 로고    scopus 로고
    • A pH-responsive hydroquinone-functionalised glassy carbon electrode
    • Yang X, Hall SB, Burrell AK, Officer DL (2001) A pH-responsive hydroquinone-functionalised glassy carbon electrode. Chem Commun 24: 2628-2629.
    • (2001) Chem Commun , vol.24 , pp. 2628-2629
    • Yang, X.1    Hall, S.B.2    Burrell, A.K.3    Officer, D.L.4
  • 11
    • 78651422127 scopus 로고    scopus 로고
    • Study of the pH function of a mechanically renewed graphite-quinhydrone indicator electrode
    • Skvortsova LI, Karunina OV, Bek RY (2010) Study of the pH function of a mechanically renewed graphite-quinhydrone indicator electrode. J Anal Chem 65: 854-860.
    • (2010) J Anal Chem , vol.65 , pp. 854-860
    • Skvortsova, L.I.1    Karunina, O.V.2    Bek, R.Y.3
  • 12
    • 64749086889 scopus 로고    scopus 로고
    • A sensitive and highly stable polypyrrole-based pH sensor with hydroquinone monosulfonate and oxalate co-doping
    • Prissanaroon-Ouajai W, Pigram PJ, Jones R, Sirivat A (2009) A sensitive and highly stable polypyrrole-based pH sensor with hydroquinone monosulfonate and oxalate co-doping. Sens Actuators B Chem 138: 504-511.
    • (2009) Sens Actuators B Chem , vol.138 , pp. 504-511
    • Prissanaroon-Ouajai, W.1    Pigram, P.J.2    Jones, R.3    Sirivat, A.4
  • 16
    • 37649018729 scopus 로고    scopus 로고
    • Applications of ionic liquids in electrochemical sensors
    • Wei D, Ivaska A (2008) Applications of ionic liquids in electrochemical sensors. Anal Chim Acta 607: 126-135.
    • (2008) Anal Chim Acta , vol.607 , pp. 126-135
    • Wei, D.1    Ivaska, A.2
  • 17
    • 78649705726 scopus 로고    scopus 로고
    • Development of an ionic liquid modified screen-printed graphite electrode and its sensing in determination of dopamine
    • Ping JF, Wu J, Ying YB (2010) Development of an ionic liquid modified screen-printed graphite electrode and its sensing in determination of dopamine. Electrochem Commun 12: 1738-1741.
    • (2010) Electrochem Commun , vol.12 , pp. 1738-1741
    • Ping, J.F.1    Wu, J.2    Ying, Y.B.3
  • 18
    • 77950322676 scopus 로고    scopus 로고
    • New frontiers in materials science opened by ionic liquids
    • Torimoto T, Tsuda T, Okazaki K, Kuwabata S (2010) New frontiers in materials science opened by ionic liquids. Adv Mater 22: 1196-1221.
    • (2010) Adv Mater , vol.22 , pp. 1196-1221
    • Torimoto, T.1    Tsuda, T.2    Okazaki, K.3    Kuwabata, S.4
  • 20
    • 21844474081 scopus 로고    scopus 로고
    • Ionic liquids promote selective responses towards the highly hydrophilic anion sulfate in PVC membrane ion-selective electrodes
    • Coll C, Labrador RH, Mañez RM, Soto J, Sancenón F, Seguí MJ, Sanchez E (2005) Ionic liquids promote selective responses towards the highly hydrophilic anion sulfate in PVC membrane ion-selective electrodes. Chem Commun 24: 3033-3035.
    • (2005) Chem Commun , vol.24 , pp. 3033-3035
    • Coll, C.1    Labrador, R.H.2    Mañez, R.M.3    Soto, J.4    Sancenón, F.5    Seguí, M.J.6    Sanchez, E.7
  • 21
    • 58149265223 scopus 로고    scopus 로고
    • A novel approach for the design of a highly selective sulfate-ion-selective electrode
    • Sathyapalan A, Zhou A, Kar T, Zhou F, Su H (2009) A novel approach for the design of a highly selective sulfate-ion-selective electrode. Chem Commun 3: 325-327.
    • (2009) Chem Commun , vol.3 , pp. 325-327
    • Sathyapalan, A.1    Zhou, A.2    Kar, T.3    Zhou, F.4    Su, H.5
  • 22
    • 46449135094 scopus 로고    scopus 로고
    • Potentiometric response of ion-selective membranes with ionic liquids as ion-exchanger and plasticizer
    • Peng B, Zhu JW, Liu XJ, Qin Y (2008) Potentiometric response of ion-selective membranes with ionic liquids as ion-exchanger and plasticizer. Sens Actuators B Chem 133: 308-314.
    • (2008) Sens Actuators B Chem , vol.133 , pp. 308-314
    • Peng, B.1    Zhu, J.W.2    Liu, X.J.3    Qin, Y.4
  • 23
    • 33845454574 scopus 로고    scopus 로고
    • Ionic liquids: new generation stable plasticizers for poly(vinyl chloride)
    • Rahman M, Brazel CS (2006) Ionic liquids: new generation stable plasticizers for poly(vinyl chloride). Polym Degrad Stab 91: 3371-3382.
    • (2006) Polym Degrad Stab , vol.91 , pp. 3371-3382
    • Rahman, M.1    Brazel, C.S.2
  • 24
    • 78650763185 scopus 로고    scopus 로고
    • Lowering the resistivity of polyacrylate ion-selective membranes by platinum nanoparticles addition
    • Jaworska E, Kisiel A, Maksymiuk K, Michalska A (2011) Lowering the resistivity of polyacrylate ion-selective membranes by platinum nanoparticles addition. Anal Chem 83: 438-445.
    • (2011) Anal Chem , vol.83 , pp. 438-445
    • Jaworska, E.1    Kisiel, A.2    Maksymiuk, K.3    Michalska, A.4
  • 26
    • 29144435222 scopus 로고    scopus 로고
    • Potentiometric pH sensors based on electrodeposited polymers
    • Lakard B, Herlem G, Lakard S, Guyetant R, Fahys B (2005) Potentiometric pH sensors based on electrodeposited polymers. Polymer 46: 12233-12239.
    • (2005) Polymer , vol.46 , pp. 12233-12239
    • Lakard, B.1    Herlem, G.2    Lakard, S.3    Guyetant, R.4    Fahys, B.5
  • 27
    • 71449104971 scopus 로고    scopus 로고
    • Solid-contact pH-selective electrode using multi-walled carbon nanotubes
    • Crespo GA, Gugsa D, Macho S, Rius FX (2009) Solid-contact pH-selective electrode using multi-walled carbon nanotubes. Anal Bioanal Chem 395: 2371-2376.
    • (2009) Anal Bioanal Chem , vol.395 , pp. 2371-2376
    • Crespo, G.A.1    Gugsa, D.2    Macho, S.3    Rius, F.X.4
  • 28
    • 18144395414 scopus 로고    scopus 로고
    • Teaching pH measurements with a student-assembled combination quinhydrone electrode
    • Scholz F, Steinhardt T, Kahlert H, Pörksen J, Behnert J (2005) Teaching pH measurements with a student-assembled combination quinhydrone electrode. J Chem Educ 82: 782-786.
    • (2005) J Chem Educ , vol.82 , pp. 782-786
    • Scholz, F.1    Steinhardt, T.2    Kahlert, H.3    Pörksen, J.4    Behnert, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.