메뉴 건너뛰기




Volumn 89, Issue 1, 2012, Pages 4-11

Changes in peripapillary retinal nerve fiber layer distribution by axial length

Author keywords

Axial length; Eye; Optical coherence tomography; Retinal nerve fiber layer

Indexed keywords

ANGULAR LOCATIONS; AUTOREFRACTION; AXIAL LENGTH; EYE; LOGISTIC REGRESSION MODELS; PROBABILITY LEVELS; RETINAL NERVE FIBER LAYERS; SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY; THICKNESS ANALYSIS; THICKNESS VALUE;

EID: 84855354947     PISSN: 10405488     EISSN: None     Source Type: Journal    
DOI: 10.1097/OPX.0b013e3182358008     Document Type: Article
Times cited : (62)

References (26)
  • 1
    • 0026642603 scopus 로고
    • An evaluation of optic disc and nerve fiber layer examinations in monitoring progression of early glaucoma damage
    • Quigley HA, Katz J, Derick RJ, Gilbert D, Sommer A. An evaluation of optic disc and nerve fiber layer examinations in monitoring progression of early glaucoma damage. Ophthalmology 1992;99:19-28.
    • (1992) Ophthalmology , vol.99 , pp. 19-28
    • Quigley, H.A.1    Katz, J.2    Derick, R.J.3    Gilbert, D.4    Sommer, A.5
  • 2
    • 11344261778 scopus 로고    scopus 로고
    • Sensitivity and specificity of the StratusOCT for perimetric glaucoma
    • DOI 10.1016/j.ophtha.2004.06.039, PII S0161642004011315
    • Budenz DL, Michael A, Chang RT, McSoley J, Katz J. Sensitivity and specificity of the StratusOCT for perimetric glaucoma. Ophthalmology 2005;112:3-9. (Pubitemid 40075311)
    • (2005) Ophthalmology , vol.112 , Issue.1 , pp. 3-9
    • Budenz, D.L.1    Michael, A.2    Chang, R.T.3    McSoley, J.4    Katz, J.5
  • 4
    • 84855344920 scopus 로고    scopus 로고
    • Carl Zeiss Meditec, Inc. CirrusHD-OCTUser Manual. Dublin, CA: Carl Zeiss Meditec, Inc.; 2009
    • Carl Zeiss Meditec, Inc. CirrusHD-OCTUser Manual. Dublin, CA: Carl Zeiss Meditec, Inc.; 2009.
  • 5
    • 79551570246 scopus 로고    scopus 로고
    • Cirrus Optical Coherence Tomography Normative Database Study Group. Ability of cirrus HD-OCT optic nerve head parameters to discriminate normal from glaucomatous eyes
    • Mwanza JC, Oakley JD, Budenz DL, Anderson DR; Cirrus Optical Coherence Tomography Normative Database Study Group. Ability of cirrus HD-OCT optic nerve head parameters to discriminate normal from glaucomatous eyes. Ophthalmology 2011;118:241-8.e1.
    • (2011) Ophthalmology , vol.118
    • Mwanza, J.C.1    Oakley, J.D.2    Budenz, D.L.3    Anderson, D.R.4
  • 6
    • 33646374199 scopus 로고    scopus 로고
    • Peripapillary retinal nerve fiber layer thickness variations with myopia
    • DOI 10.1016/j.ophtha.2006.01.058, PII S0161642006001564
    • Hoh ST, Lim MC, Seah SK, Lim AT, Chew SJ, Foster PJ, Aung T. Peripapillary retinal nerve fiber layer thickness variations with myopia. Ophthalmology 2006;113:773-7. (Pubitemid 44294302)
    • (2006) Ophthalmology , vol.113 , Issue.5 , pp. 773-777
    • Hoh, S.-T.1    Lim, M.C.C.2    Seah, S.K.L.3    Lim, A.T.H.4    Chew, S.-J.5    Foster, P.J.6    Aung, T.7
  • 7
    • 34447544666 scopus 로고    scopus 로고
    • The effect of scan diameter on retinal nerve fiber layer thickness measurement using stratus optic coherence tomography
    • DOI 10.1001/archopht.125.7.901
    • Savini G, Barboni P, Carbonelli M, Zanini M. The effect of scan diameter on retinal nerve fiber layer thickness measurement using stratus optic coherence tomography. Arch Ophthalmol 2007;125: 901-5. (Pubitemid 47076426)
    • (2007) Archives of Ophthalmology , vol.125 , Issue.7 , pp. 901-905
    • Savini, G.1    Barboni, P.2    Carbonelli, M.3    Zanini, M.4
  • 9
    • 70349736463 scopus 로고    scopus 로고
    • Myopia affects retinal nerve fiber layer measurements as determined by optical coherence tomography
    • Rauscher FM, Sekhon N, Feuer WJ, Budenz DL. Myopia affects retinal nerve fiber layer measurements as determined by optical coherence tomography. J Glaucoma 2009;18:501-5.
    • (2009) J Glaucoma , vol.18 , pp. 501-5
    • Rauscher, F.M.1    Sekhon, N.2    Feuer, W.J.3    Budenz, D.L.4
  • 10
    • 74549141054 scopus 로고    scopus 로고
    • Peripapillary retinal nerve fibre layer thickness profile in subjects with myopia measured using the Stratus optical coherence tomography
    • Kim MJ, Lee EJ, Kim TW. Peripapillary retinal nerve fibre layer thickness profile in subjects with myopia measured using the Stratus optical coherence tomography. Br J Ophthalmol 2010;94:115-20.
    • (2010) Br J Ophthalmol , vol.94 , pp. 115-20
    • Kim, M.J.1    Lee, E.J.2    Kim, T.W.3
  • 11
    • 84455205466 scopus 로고    scopus 로고
    • The influence of axial length on retinal nerve fibre layer thickness and optic-disc size measurements by spectral-domain OCT
    • February 24, 2011
    • Savini G, Barboni P, Parisi V, Carbonelli M. The influence of axial length on retinal nerve fibre layer thickness and optic-disc size measurements by spectral-domain OCT. Br J Ophthalmol 2011. (e-pub February 24, 2011).
    • (2011) Br J Ophthalmol
    • Savini, G.1    Barboni, P.2    Parisi, V.3    Carbonelli, M.4
  • 12
    • 77955906560 scopus 로고    scopus 로고
    • Effect of myopia on the thickness of the retinal nerve fiber layer measured by Cirrus HD optical coherence tomography
    • Kang SH, Hong SW, Im SK, Lee SH, Ahn MD. Effect of myopia on the thickness of the retinal nerve fiber layer measured by Cirrus HD optical coherence tomography. Invest Ophthalmol Vis Sci 2010;51: 4075-83.
    • (2010) Invest Ophthalmol Vis Sci , vol.51 , pp. 4075-83
    • Kang, S.H.1    Hong, S.W.2    Im, S.K.3    Lee, S.H.4    Ahn, M.D.5
  • 13
    • 0014589429 scopus 로고
    • Estimation of width of angle of anterior chamber. Incidence and significance of the narrow angle
    • Van Herick W, Shaffer RN, Schwartz A. Estimation of width of angle of anterior chamber. Incidence and significance of the narrow angle. Am J Ophthalmol 1969;68:626-9.
    • (1969) Am J Ophthalmol , vol.68 , pp. 626-9
    • Van Herick, W.1    Shaffer, R.N.2    Schwartz, A.3
  • 14
    • 79251519971 scopus 로고    scopus 로고
    • The effect of myopia on retinal nerve fibre layer measurement: A comparative study of spectral-domain optical coherence tomography and scanning laser polarimetry
    • Wang G, Qiu KL, Lu XH, Sun LX, Liao XJ, Chen HL, Zhang MZ. The effect of myopia on retinal nerve fibre layer measurement: a comparative study of spectral-domain optical coherence tomography and scanning laser polarimetry. Br J Ophthalmol 2011;95:255-60.
    • (2011) Br J Ophthalmol , vol.95 , pp. 255-60
    • Wang, G.1    Qiu, K.L.2    Lu, X.H.3    Sun, L.X.4    Liao, X.J.5    Chen, H.L.6    Zhang, M.Z.7
  • 16
    • 58149352680 scopus 로고    scopus 로고
    • Blood vessel contributions to retinal nerve fiber layer thickness profiles measured with optical coherence tomography
    • Hood DC, Fortune B, Arthur SN, Xing D, Salant JA, Ritch R, Liebmann JM. Blood vessel contributions to retinal nerve fiber layer thickness profiles measured with optical coherence tomography. J Glaucoma 2008;17:519-28.
    • (2008) J Glaucoma , vol.17 , pp. 519-28
    • Hood, D.C.1    Fortune, B.2    Arthur, S.N.3    Xing, D.4    Salant, J.A.5    Ritch, R.6    Liebmann, J.M.7
  • 17
    • 79955002983 scopus 로고    scopus 로고
    • Position of retinal blood vessels correlates with retinal nerve fibre layer thickness profiles as measured with GDx VCC and ECC
    • Resch H, Brela B, Resch-Wolfslehner C, Vass C. Position of retinal blood vessels correlates with retinal nerve fibre layer thickness profiles as measured with GDx VCC and ECC. Br J Ophthalmol 2011;95: 680-4.
    • (2011) Br J Ophthalmol , vol.95 , pp. 680-4
    • Resch, H.1    Brela, B.2    Resch-Wolfslehner, C.3    Vass, C.4
  • 18
    • 22444447946 scopus 로고    scopus 로고
    • Common mechanisms of nerve and blood vessel wiring
    • DOI 10.1038/nature03875
    • Carmeliet P, Tessier-Lavigne M. Common mechanisms of nerve and blood vessel wiring. Nature 2005;436:193-200. (Pubitemid 41021263)
    • (2005) Nature , vol.436 , Issue.7048 , pp. 193-200
    • Carmeliet, P.1    Tessier-Lavigne, M.2
  • 19
    • 58149128134 scopus 로고    scopus 로고
    • Effect of improper scan alignment on retinal nerve fiber layer thickness measurements using Stratus optical coherence tomograph
    • Vizzeri G, Bowd C, Medeiros FA, Weinreb RN, Zangwill LM. Effect of improper scan alignment on retinal nerve fiber layer thickness measurements using Stratus optical coherence tomograph. J Glaucoma 2008;17:341-9.
    • (2008) J Glaucoma , vol.17 , pp. 341-9
    • Vizzeri, G.1    Bowd, C.2    Medeiros, F.A.3    Weinreb, R.N.4    Zangwill, L.M.5
  • 21
    • 0020004188 scopus 로고
    • ZUR BESTIMMUNG DER WAHREN GROSSE EINES OBJEKTES AUF DEM HINTERGRUND DES LEBENDEN AUGES
    • Littmann H. [Determination of the real size of an object on the fundus of the living eye.] Klin Monbl Augenheilkd 1982;180:286-9. (Pubitemid 12156016)
    • (1982) Klinische Monatsblatter fur Augenheilkunde , vol.180 , Issue.4 , pp. 286-289
    • Littmann, H.1
  • 23
    • 14244254587 scopus 로고    scopus 로고
    • Optic disk size correlated with refractive error
    • DOI 10.1016/j.ajo.2004.07.047
    • Jonas JB. Optic disk size correlated with refractive error. Am J Ophthalmol 2005;139:346-8. (Pubitemid 40288284)
    • (2005) American Journal of Ophthalmology , vol.139 , Issue.2 , pp. 346-348
    • Jonas, J.B.1
  • 24
    • 0028188689 scopus 로고
    • A CT study of the relation between ocular axial biometry and refraction
    • Wang FR, Zhou XD, Zhou SZ. [A CT study of the relation between ocular axial biometry and refraction.] Zhonghua Yan Ke Za Zhi 1994;30:39-40.
    • (1994) Zhonghua Yan Ke Za Zhi , vol.30 , pp. 39-40
    • Wang, F.R.1    Zhou, X.D.2    Zhou, S.Z.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.