메뉴 건너뛰기




Volumn 18, Issue 1, 2012, Pages

Cranioplasty prosthesis manufacturing based on reverse engineering technology

Author keywords

Cranioplasty; CT; Rapid prototyping; Reverse engineering

Indexed keywords

POLYESTER; POLYPROPYLENE;

EID: 84855281422     PISSN: 12341010     EISSN: 16433750     Source Type: Journal    
DOI: 10.12659/msm.882186     Document Type: Article
Times cited : (28)

References (28)
  • 1
    • 0031093586 scopus 로고    scopus 로고
    • Repairing holes in the head: A history of cranioplasty
    • Sanan A, Haines SJ: Repairing holes in the head: a history of cranioplasty. Neurosurgery, 1997; 40: 588-603
    • (1997) Neurosurgery , vol.40 , pp. 588-603
    • Sanan, A.1    Haines, S.J.2
  • 2
    • 0030899201 scopus 로고    scopus 로고
    • Cranioplasty: Cosmetic or therapeutic?
    • Dujovny M, Aviles A, Agner C et al: Cranioplasty: cosmetic or therapeutic? Surg Neurol, 1997; 47: 238-41
    • (1997) Surg Neurol , vol.47 , pp. 238-241
    • Dujovny, M.1    Aviles, A.2    Agner, C.3
  • 3
    • 0033922919 scopus 로고    scopus 로고
    • Influence of cranioplasty on postural blood flow regulation, cerebrovascular reserve capacity, and cerebral glucose metabolism
    • Winkler PA, Stummer W, Linke R et al: Influence of cranioplasty on postural blood flow regulation, cerebrovascular reserve capacity, and cerebral glucose metabolism. J Neurosurg, 2000; 93: 53-61
    • (2000) J Neurosurg , vol.93 , pp. 53-61
    • Winkler, P.A.1    Stummer, W.2    Linke, R.3
  • 4
    • 3042800167 scopus 로고    scopus 로고
    • Neurological improvement after cranioplasty - analysis by transcranial Doppler ultrasonography
    • Kuo JR, Wang CC, Chio CC et al: Neurological improvement after cranioplasty - analysis by transcranial Doppler ultrasonography. J Clin Neurosci, 2004; 11: 486-89
    • (2004) J Clin Neurosci , vol.11 , pp. 486-489
    • Kuo, J.R.1    Wang, C.C.2    Chio, C.C.3
  • 5
    • 4644231745 scopus 로고    scopus 로고
    • Sinking skin flap syndrome. A case of improved cerebral blood flow after cranioplasty
    • Isago T, Nozaki M, Kikuchi Y et al: Sinking skin flap syndrome. A case of improved cerebral blood flow after cranioplasty. Ann Plast Surg, 2004; 53: 288-92
    • (2004) Ann Plast Surg , vol.53 , pp. 288-292
    • Isago, T.1    Nozaki, M.2    Kikuchi, Y.3
  • 6
    • 33746928818 scopus 로고    scopus 로고
    • CT perfusion imaging in the syndrome of the sinking skin flap before and after cranioplasty
    • Sakamoto S, Eguchi K, Kiura Y et al: CT perfusion imaging in the syndrome of the sinking skin flap before and after cranioplasty. Clin Neurol Neurosurg, 2006; 108: 583-85
    • (2006) Clin Neurol Neurosurg , vol.108 , pp. 583-585
    • Sakamoto, S.1    Eguchi, K.2    Kiura, Y.3
  • 7
    • 0037371676 scopus 로고    scopus 로고
    • The use of frozen autogenous bone flaps in delayed cranioplasty revisited
    • Iwama T, Yamada J, Imai S et al: The use of frozen autogenous bone flaps in delayed cranioplasty revisited. Neurosurgery, 2003; 52: 591-95
    • (2003) Neurosurgery , vol.52 , pp. 591-595
    • Iwama, T.1    Yamada, J.2    Imai, S.3
  • 8
    • 0035024433 scopus 로고    scopus 로고
    • Successful use of rib grafts for cranioplasty in children
    • Taggard DA, Menezes AH: Successful use of rib grafts for cranioplasty in children, Pediatr Neurosurg, 2001; 34: 149-55
    • (2001) Pediatr Neurosurg , vol.34 , pp. 149-155
    • Taggard, D.A.1    Menezes, A.H.2
  • 9
    • 0033458787 scopus 로고    scopus 로고
    • A prospective study of computer-aided design and manufacture of titanium plate for cranioplasty and its clinical outcome
    • Joffe J, Harris M, Kahugu F et al: A prospective study of computer-aided design and manufacture of titanium plate for cranioplasty and its clinical outcome. Brit J Neurosurg, 1999; 13: 576-80
    • (1999) Brit J Neurosurg , vol.13 , pp. 576-580
    • Joffe, J.1    Harris, M.2    Kahugu, F.3
  • 10
    • 0033169246 scopus 로고    scopus 로고
    • Validation of computer assisted manufacture of titanium plates for cranioplasty
    • Joffe JM, Nicoll SR, Richards R et al: Validation of computer assisted manufacture of titanium plates for cranioplasty. Int J Oral Maxillofac Surg, 1999; 28: 309-13
    • (1999) Int J Oral Maxillofac Surg , vol.28 , pp. 309-313
    • Joffe, J.M.1    Nicoll, S.R.2    Richards, R.3
  • 11
    • 33644853692 scopus 로고    scopus 로고
    • Cranioplasty with subcutaneously preserved autologous bone grafts
    • Movassaghi K, Ver Halen J, Ganchi P et al: Cranioplasty with subcutaneously preserved autologous bone grafts. Plast Reconstr Surg, 2006; 117: 202-6
    • (2006) Plast Reconstr Surg , vol.117 , pp. 202-206
    • Movassaghi, K.1    Ver, H.J.2    Ganchi, P.3
  • 12
    • 56849095796 scopus 로고    scopus 로고
    • Cranioplasty using polymethyl methacrylate prostheses
    • Lee SC, Wu CT, Lee ST et al: Cranioplasty using polymethyl methacrylate prostheses. J Clin Neurosci, 2009; 16: 56-63
    • (2009) J Clin Neurosci , vol.16 , pp. 56-63
    • Lee, S.C.1    Wu, C.T.2    Lee, S.T.3
  • 13
    • 44649132790 scopus 로고    scopus 로고
    • Cost-effective patient-specific intraoperative molded cranioplasty
    • Fathi AR, Marbacher S, Lukes A: Cost-effective patient-specific intraoperative molded cranioplasty. J Craniofac Surg, 2008; 19: 777-81
    • (2008) J Craniofac Surg , vol.19 , pp. 777-781
    • Fathi, A.R.1    Marbacher, S.2    Lukes, A.3
  • 14
    • 33646128722 scopus 로고    scopus 로고
    • Silicone rubber mould cast polyethylmethacrylate-hydroxyapatite plate used for repairing a large skull defect
    • Rotaru H, Baciut M, Stan H et al: Silicone rubber mould cast polyethylmethacrylate-hydroxyapatite plate used for repairing a large skull defect. J Craniomaxillofac Surg, 2006; 34: 242-46
    • (2006) J Craniomaxillofac Surg , vol.34 , pp. 242-246
    • Rotaru, H.1    Baciut, M.2    Stan, H.3
  • 15
    • 0036434524 scopus 로고    scopus 로고
    • Cranioplasty with individual carbon fibre reinforced polymere (CFRP) medical grade implants based on CAD/CAM technique
    • Saringer W, Nöbauer-Huhmann I, Knosp E: Cranioplasty with individual carbon fibre reinforced polymere (CFRP) medical grade implants based on CAD/CAM technique. Acta Neurochir (Wien), 2002; 144: 1193-203
    • (2002) Acta Neurochir (Wien) , vol.144 , pp. 1193-1203
    • Saringer, W.1    Nöbauer-Huhmann, I.2    Knosp, E.3
  • 16
    • 23844510069 scopus 로고    scopus 로고
    • Clinical evaluation of the polypropylene-polyester knit used as a cranioplasty material
    • Andrzejak S, Fortuniak J, Wróbel-Wiśniewska G et al: Clinical evaluation of the polypropylene-polyester knit used as a cranioplasty material. Acta Neurochir (Wien), 2005; 147: 973-76
    • (2005) Acta Neurochir (Wien) , vol.147 , pp. 973-976
    • Andrzejak, S.1    Fortuniak, J.2    Wróbel-Wiśniewska, G.3
  • 17
    • 57749189537 scopus 로고    scopus 로고
    • From computerized tomography data processing to rapid manufacturing of custom-made prostheses for cranioplasty. Case report
    • Solaro P, Pierangeli E, Pizzoni C et al: From computerized tomography data processing to rapid manufacturing of custom-made prostheses for cranioplasty. Case report. J Neurosurg Sci, 2008; 52: 113-16
    • (2008) J Neurosurg Sci , vol.52 , pp. 113-116
    • Solaro, P.1    Pierangeli, E.2    Pizzoni, C.3
  • 18
    • 39749195404 scopus 로고    scopus 로고
    • Reverse engineering techniques for cranioplasty: A case study
    • Maravelakis E, David K, Antoniadis A et al: Reverse engineering techniques for cranioplasty: a case study. J Med Eng Technol, 2008; 32: 115-21
    • (2008) J Med Eng Technol , vol.32 , pp. 115-121
    • Maravelakis, E.1    David, K.2    Antoniadis, A.3
  • 19
    • 85052608896 scopus 로고    scopus 로고
    • Taylored implants for alloplastic cranioplasty - clinical and surgical considerations
    • Hoffmann B, Sepehrnia A: Taylored implants for alloplastic cranioplasty - clinical and surgical considerations. Acta Neurochir Suppl, 2005; 93: 127-29
    • (2005) Acta Neurochir Suppl , vol.93 , pp. 127-129
    • Hoffmann, B.1    Sepehrnia, A.2
  • 20
    • 23844477622 scopus 로고    scopus 로고
    • CAD generated mold for preoperative implant fabrication in cranioplasty
    • Wulf J, Busch LC, Golz T et al: CAD generated mold for preoperative implant fabrication in cranioplasty. Stud Health Technol Inform, 2005; 111: 608-10
    • (2005) Stud Health Technol Inform , vol.111 , pp. 608-610
    • Wulf, J.1    Busch, L.C.2    Golz, T.3
  • 21
    • 18144440405 scopus 로고    scopus 로고
    • The application of rapid prototyping techniques in cranial reconstruction and preoperative planning in neurosurgery
    • Müller A, Krishnan KG, Uhl E et al: The application of rapid prototyping techniques in cranial reconstruction and preoperative planning in neurosurgery. J Craniofac Surg, 2003; 14: 899-914
    • (2003) J Craniofac Surg , vol.14 , pp. 899-914
    • Müller, A.1    Krishnan, K.G.2    Uhl, E.3
  • 22
    • 0033998729 scopus 로고    scopus 로고
    • Custom cranioplasty using stereolithography and acrylic
    • D'Urso PS, Earwaker WJ, Barker TM et al: Custom cranioplasty using stereolithography and acrylic. Br J Plast Surg, 2000; 53: 200-4
    • (2000) Br J Plast Surg , vol.53 , pp. 200-204
    • D'urso, P.S.1    Earwaker, W.J.2    Barker, T.M.3
  • 23
    • 0031954379 scopus 로고    scopus 로고
    • Stereolithography for posterior fossa cranioplasty
    • Agner C, Dujovny M, Evenhouse R et al: Stereolithography for posterior fossa cranioplasty. Skull Base Surg, 1998; 8: 81-86
    • (1998) Skull Base Surg , vol.8 , pp. 81-86
    • Agner, C.1    Dujovny, M.2    Evenhouse, R.3
  • 24
    • 1542758589 scopus 로고    scopus 로고
    • Computer aided design of large-format prefabricated cranial plates
    • Dean D, Min KJ, Bond A: Computer aided design of large-format prefabricated cranial plates. J Craniofac Surg, 2003; 14: 819-32
    • (2003) J Craniofac Surg , vol.14 , pp. 819-832
    • Dean, D.1    Min, K.J.2    Bond, A.3
  • 25
    • 77956338910 scopus 로고    scopus 로고
    • Customised fabricated implants after previous failed cranioplasty
    • Goh RC, Chang CN, Lin CL et al: Customised fabricated implants after previous failed cranioplasty. J Plast Reconstr Aesthet Surg, 2010; 63: 1479-84
    • (2010) J Plast Reconstr Aesthet Surg , vol.63 , pp. 1479-1484
    • Goh, R.C.1    Chang, C.N.2    Lin, C.L.3
  • 26
    • 0036396307 scopus 로고    scopus 로고
    • Design and manufacturing of cranioplasty implants by 3-axis cnc milling
    • Hieu, LC, Bohez E, Sloten J et al: Design and manufacturing of cranioplasty implants by 3-axis cnc milling. Technol Health Care, 2002; 10: 413-23
    • (2002) Technol Health Care , vol.10 , pp. 413-423
    • Hieu, L.C.1    Bohez, E.2    Sloten, J.3
  • 27
    • 77949403527 scopus 로고    scopus 로고
    • CAD/CAM prefabricated individual skull implants: New aspects in robot resection and guided bone regeneration
    • Weihe S, Schiller C, Rasche C et al: CAD/CAM prefabricated individual skull implants: new aspects in robot resection and guided bone regeneration. International Congress Series, 2004; 1268: 584-90
    • (2004) International Congress Series , vol.1268 , pp. 584-590
    • Weihe, S.1    Schiller, C.2    Rasche, C.3
  • 28
    • 80051499078 scopus 로고    scopus 로고
    • Patient specific implants, designed using Rapid Prototyping and diagnostic imaging, for the repair of orbital fractures
    • Elgalal M, Kozakiewicz M, Loba P et al: Patient specific implants, designed using Rapid Prototyping and diagnostic imaging, for the repair of orbital fractures. Med Sci Monit, 2010; 16(Suppl.1): 75-7
    • (2010) Med Sci Monit , vol.16 , Issue.1 SUPPL. , pp. 75-77
    • Elgalal, M.1    Kozakiewicz, M.2    Loba, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.