메뉴 건너뛰기




Volumn 19, Issue 2, 2012, Pages 184-190

Design Considerations for using PET as a Response Measure in Single Site and Multicenter Clinical Trials

Author keywords

FDG PET; Multicenter trial design; Sample size; SUV

Indexed keywords

ANTINEOPLASTIC AGENT; FLUORODEOXYGLUCOSE F 18;

EID: 84855272218     PISSN: 10766332     EISSN: 18784046     Source Type: Journal    
DOI: 10.1016/j.acra.2011.10.008     Document Type: Article
Times cited : (29)

References (29)
  • 1
    • 32044438650 scopus 로고    scopus 로고
    • Positron-emission tomography and assessment of cancer therapy
    • Juweid M.E., Cheson B.D. Positron-emission tomography and assessment of cancer therapy. N Engl J Med 2006, 354:496-507.
    • (2006) N Engl J Med , vol.354 , pp. 496-507
    • Juweid, M.E.1    Cheson, B.D.2
  • 2
    • 66149139452 scopus 로고    scopus 로고
    • From RECIST to PERCIST: evolving considerations for PET response criteria in solid tumors
    • Wahl R.L., Jacene H., Kasamon Y., et al. From RECIST to PERCIST: evolving considerations for PET response criteria in solid tumors. J Nucl Med 2009, 50(Suppl 1):122S-150S.
    • (2009) J Nucl Med , vol.50 , Issue.SUPPL. 1
    • Wahl, R.L.1    Jacene, H.2    Kasamon, Y.3
  • 3
    • 57849117384 scopus 로고    scopus 로고
    • New response evaluation criteria in solid tumours: revised RECIST guideline (version 1.1)
    • Eisenhauer E.A., Therasse P., Bogaerts J., et al. New response evaluation criteria in solid tumours: revised RECIST guideline (version 1.1). EurJCancer 2009, 45:228-247.
    • (2009) EurJCancer , vol.45 , pp. 228-247
    • Eisenhauer, E.A.1    Therasse, P.2    Bogaerts, J.3
  • 4
    • 0032757213 scopus 로고    scopus 로고
    • Measurement of clinical and subclinical tumour response using [18F]-fluorodeoxyglucose and positron emission tomography: review and 1999 EORTC recommendations. European Organization for Research and Treatment of Cancer (EORTC) PET Study Group
    • Young H., Baum R., Cremerius U., et al. Measurement of clinical and subclinical tumour response using [18F]-fluorodeoxyglucose and positron emission tomography: review and 1999 EORTC recommendations. European Organization for Research and Treatment of Cancer (EORTC) PET Study Group. Eur J Cancer 1999, 35:1773-1782.
    • (1999) Eur J Cancer , vol.35 , pp. 1773-1782
    • Young, H.1    Baum, R.2    Cremerius, U.3
  • 5
    • 33746036112 scopus 로고    scopus 로고
    • Consensus recommendations for the use of 18F-FDG PET as an indicator of therapeutic response in patients in National Cancer Institute Trials
    • Shankar L.K., Hoffman J.M., Bacharach S., et al. Consensus recommendations for the use of 18F-FDG PET as an indicator of therapeutic response in patients in National Cancer Institute Trials. J Nucl Med 2006, 47:1059-1066.
    • (2006) J Nucl Med , vol.47 , pp. 1059-1066
    • Shankar, L.K.1    Hoffman, J.M.2    Bacharach, S.3
  • 6
    • 66149106325 scopus 로고    scopus 로고
    • Standards for PET image acquisition and quantitative data analysis
    • Boellaard R. Standards for PET image acquisition and quantitative data analysis. J Nucl Med 2009, 50(Suppl 1):11S-20S.
    • (2009) J Nucl Med , vol.50 , Issue.SUPPL. 1
    • Boellaard, R.1
  • 7
    • 0032716268 scopus 로고    scopus 로고
    • Reproducibility of metabolic measurements in malignant tumors using FDG PET
    • Weber W., Ziegler S., Thodtmann R., et al. Reproducibility of metabolic measurements in malignant tumors using FDG PET. J Nucl Med 1999, 40:1771-1777.
    • (1999) J Nucl Med , vol.40 , pp. 1771-1777
    • Weber, W.1    Ziegler, S.2    Thodtmann, R.3
  • 8
    • 33745955010 scopus 로고    scopus 로고
    • Positron emission tomography as an imaging biomarker
    • Weber W.A. Positron emission tomography as an imaging biomarker. J Clin Oncol 2006, 24:3282-3292.
    • (2006) J Clin Oncol , vol.24 , pp. 3282-3292
    • Weber, W.A.1
  • 9
    • 0027442958 scopus 로고
    • Metabolic monitoring of breast cancer chemohormonotherapy using positron emission tomography: Initial evaluation
    • Wahl R.L., Zasadny K., Helvie M., et al. Metabolic monitoring of breast cancer chemohormonotherapy using positron emission tomography: Initial evaluation. J Clin Oncol 1993, 11:2101-2111.
    • (1993) J Clin Oncol , vol.11 , pp. 2101-2111
    • Wahl, R.L.1    Zasadny, K.2    Helvie, M.3
  • 10
    • 52449103839 scopus 로고    scopus 로고
    • Tumor metabolism and blood flow changes by positron emission tomography: relation to survival in patients treated with neoadjuvant chemotherapy for locally advanced breast cancer
    • Dunnwald L.K., Gralow J.R., Ellis G.K., et al. Tumor metabolism and blood flow changes by positron emission tomography: relation to survival in patients treated with neoadjuvant chemotherapy for locally advanced breast cancer. J Clin Oncol 2008, 26:4449-4457.
    • (2008) J Clin Oncol , vol.26 , pp. 4449-4457
    • Dunnwald, L.K.1    Gralow, J.R.2    Ellis, G.K.3
  • 11
    • 68949102467 scopus 로고    scopus 로고
    • Lower-dose vs high-dose oral estradiol therapy of hormone receptor-positive, aromatase inhibitor-resistant advanced breast cancer: a phase 2 randomized study
    • Ellis M.J., Gao F., Dehdashti F., et al. Lower-dose vs high-dose oral estradiol therapy of hormone receptor-positive, aromatase inhibitor-resistant advanced breast cancer: a phase 2 randomized study. JAMA 2009, 302:774-780.
    • (2009) JAMA , vol.302 , pp. 774-780
    • Ellis, M.J.1    Gao, F.2    Dehdashti, F.3
  • 12
    • 0029017592 scopus 로고
    • Lung cancer: reproducibility of quantitative measurements for evaluating 2-[F-18]-fluoro-2-deoxy-D-glucose uptake at PET
    • Minn H., Zasadny K.R., Quint L.E., et al. Lung cancer: reproducibility of quantitative measurements for evaluating 2-[F-18]-fluoro-2-deoxy-D-glucose uptake at PET. Radiology 1995, 196:167-173.
    • (1995) Radiology , vol.196 , pp. 167-173
    • Minn, H.1    Zasadny, K.R.2    Quint, L.E.3
  • 13
    • 0036202726 scopus 로고    scopus 로고
    • Reproducibility of common semi-quantitative parameters for evaluating lung cancer glucose metabolism with positron emission tomography using 2-deoxy-2-[18F]fluoro-D-glucose
    • Nakamoto Y., Zasadny K.R., Minn H., et al. Reproducibility of common semi-quantitative parameters for evaluating lung cancer glucose metabolism with positron emission tomography using 2-deoxy-2-[18F]fluoro-D-glucose. Mol Imaging Biol 2002, 4:171-178.
    • (2002) Mol Imaging Biol , vol.4 , pp. 171-178
    • Nakamoto, Y.1    Zasadny, K.R.2    Minn, H.3
  • 14
    • 17644421807 scopus 로고    scopus 로고
    • Effects of ROI definition and reconstruction method on quantitative outcome and applicability in a response monitoring trial
    • Krak N.C., Boellaard R., Hoekstra O.S., et al. Effects of ROI definition and reconstruction method on quantitative outcome and applicability in a response monitoring trial. Eur J Nucl Med Mol Imaging 2005, 32:294-301.
    • (2005) Eur J Nucl Med Mol Imaging , vol.32 , pp. 294-301
    • Krak, N.C.1    Boellaard, R.2    Hoekstra, O.S.3
  • 15
    • 57349145902 scopus 로고    scopus 로고
    • Reproducibility of standardized uptake value measurements determined by 18F-FDG PET in malignant tumors
    • Nahmias C., Wahl L.M. Reproducibility of standardized uptake value measurements determined by 18F-FDG PET in malignant tumors. J Nucl Med 2008, 49:1804-1808.
    • (2008) J Nucl Med , vol.49 , pp. 1804-1808
    • Nahmias, C.1    Wahl, L.M.2
  • 16
    • 78149439474 scopus 로고    scopus 로고
    • Instrumentation factors affecting variance and bias of quantifying tracer uptake with PET/CT
    • Doot R.K., Scheuermann J.S., Christian P.E., et al. Instrumentation factors affecting variance and bias of quantifying tracer uptake with PET/CT. Med Phys 2010, 37:6035-6046.
    • (2010) Med Phys , vol.37 , pp. 6035-6046
    • Doot, R.K.1    Scheuermann, J.S.2    Christian, P.E.3
  • 17
    • 77954751024 scopus 로고    scopus 로고
    • Variability in PET quantitation within a multicenter consortium
    • Fahey F.H., Kinahan P.E., Doot R.K., et al. Variability in PET quantitation within a multicenter consortium. Med Phys 2010, 37:3660-3666.
    • (2010) Med Phys , vol.37 , pp. 3660-3666
    • Fahey, F.H.1    Kinahan, P.E.2    Doot, R.K.3
  • 18
    • 79851482552 scopus 로고    scopus 로고
    • Quantifying and reducing the effect of calibration error on variability of PET/CT standardized uptake value measurements
    • Lockhart C.M., MacDonald L.R., Alessio A.M., et al. Quantifying and reducing the effect of calibration error on variability of PET/CT standardized uptake value measurements. J Nucl Med 2011, 52:218-224.
    • (2011) J Nucl Med , vol.52 , pp. 218-224
    • Lockhart, C.M.1    MacDonald, L.R.2    Alessio, A.M.3
  • 19
    • 48749115711 scopus 로고    scopus 로고
    • Variability of lesion detectability and standardized uptake value according to the acquisition procedure and reconstruction among five PET scanners
    • Takahashi Y., Oriuchi N., Otake H., et al. Variability of lesion detectability and standardized uptake value according to the acquisition procedure and reconstruction among five PET scanners. Ann Nucl Med 2008, 22:543-548.
    • (2008) Ann Nucl Med , vol.22 , pp. 543-548
    • Takahashi, Y.1    Oriuchi, N.2    Otake, H.3
  • 20
    • 70349650689 scopus 로고    scopus 로고
    • Repeatability of 18F-FDG PET in a multicenter phase I study of patients with advanced gastrointestinal malignancies
    • Velasquez L.M., Boellaard R., Kollia G., et al. Repeatability of 18F-FDG PET in a multicenter phase I study of patients with advanced gastrointestinal malignancies. J Nucl Med 2009, 50:1646-1654.
    • (2009) J Nucl Med , vol.50 , pp. 1646-1654
    • Velasquez, L.M.1    Boellaard, R.2    Kollia, G.3
  • 21
    • 0038207710 scopus 로고    scopus 로고
    • Comparison of SUV and Patlak slope for monitoring of cancer therapy using serial PET scans
    • Freedman N.M., Sundaram S.K., Kurdziel K., et al. Comparison of SUV and Patlak slope for monitoring of cancer therapy using serial PET scans. Eur J Nucl Med Mol Imaging 2003, 30:46-53.
    • (2003) Eur J Nucl Med Mol Imaging , vol.30 , pp. 46-53
    • Freedman, N.M.1    Sundaram, S.K.2    Kurdziel, K.3
  • 22
    • 33746485010 scopus 로고    scopus 로고
    • How should we analyse FDG PET studies for monitoring tumour response?
    • Lammertsma A.A., Hoekstra C.J., Giaccone G., et al. How should we analyse FDG PET studies for monitoring tumour response?. Eur J Nucl Med Mol Imaging 2006, 33(Suppl 13):16-21.
    • (2006) Eur J Nucl Med Mol Imaging , vol.33 , Issue.SUPPL. 13 , pp. 16-21
    • Lammertsma, A.A.1    Hoekstra, C.J.2    Giaccone, G.3
  • 23
    • 33847168972 scopus 로고    scopus 로고
    • Monitoring primary breast cancer throughout chemotherapy using FDG-PET
    • McDermott G.M., Welch A., Staff R.T., et al. Monitoring primary breast cancer throughout chemotherapy using FDG-PET. Breast Cancer Res Treatment 2007, 102:75-84.
    • (2007) Breast Cancer Res Treatment , vol.102 , pp. 75-84
    • McDermott, G.M.1    Welch, A.2    Staff, R.T.3
  • 24
    • 34250348253 scopus 로고    scopus 로고
    • Dynamic and static approaches to quantifying 18F-FDG uptake for measuring cancer response to therapy, including the effect of granulocyte CSF
    • Doot R.K., Dunnwald L.K., Schubert E.K., et al. Dynamic and static approaches to quantifying 18F-FDG uptake for measuring cancer response to therapy, including the effect of granulocyte CSF. J Nucl Med 2007, 48:920-925.
    • (2007) J Nucl Med , vol.48 , pp. 920-925
    • Doot, R.K.1    Dunnwald, L.K.2    Schubert, E.K.3
  • 25
    • 77953347942 scopus 로고    scopus 로고
    • Using 18F-fluorodeoxyglucose positron emission tomography to monitor clinical outcomes in patients treated with neoadjuvant chemo-radiotherapy for locally advanced pancreatic cancer
    • Choi M., Heilbrun L.K., Venkatramanamoorthy R., et al. Using 18F-fluorodeoxyglucose positron emission tomography to monitor clinical outcomes in patients treated with neoadjuvant chemo-radiotherapy for locally advanced pancreatic cancer. Am J Clin Oncol 2010, 33:257-261.
    • (2010) Am J Clin Oncol , vol.33 , pp. 257-261
    • Choi, M.1    Heilbrun, L.K.2    Venkatramanamoorthy, R.3
  • 26
    • 79954611821 scopus 로고    scopus 로고
    • PET tumor metabolism in locally advanced breast cancer patients undergoing neoadjuvant chemotherapy: value of static versus kinetic measures of fluorodeoxyglucose uptake
    • Dunnwald L.K., Doot R.K., Specht J.M., et al. PET tumor metabolism in locally advanced breast cancer patients undergoing neoadjuvant chemotherapy: value of static versus kinetic measures of fluorodeoxyglucose uptake. Clin Cancer Res 2011, 17:2400-2409.
    • (2011) Clin Cancer Res , vol.17 , pp. 2400-2409
    • Dunnwald, L.K.1    Doot, R.K.2    Specht, J.M.3
  • 27
    • 0027367203 scopus 로고
    • Standardized uptake values of normal tissues atPET with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose: variations with body weight and a method for correction
    • Zasadny K.R., Wahl R.L. Standardized uptake values of normal tissues atPET with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose: variations with body weight and a method for correction. Radiology 1993, 189:847-850.
    • (1993) Radiology , vol.189 , pp. 847-850
    • Zasadny, K.R.1    Wahl, R.L.2
  • 28
    • 70350707776 scopus 로고    scopus 로고
    • Assessment of interobserver reproducibility in quantitative 18F-FDG PET and CT measurements of tumor response to therapy
    • Jacene H.A., Leboulleux S., Baba S., et al. Assessment of interobserver reproducibility in quantitative 18F-FDG PET and CT measurements of tumor response to therapy. J Nucl Med 2009, 50:1760-1769.
    • (2009) J Nucl Med , vol.50 , pp. 1760-1769
    • Jacene, H.A.1    Leboulleux, S.2    Baba, S.3
  • 29
    • 77956188828 scopus 로고    scopus 로고
    • Partial volume correction strategies for quantitative FDG PET in oncology
    • Hoetjes N.J., van Velden F.H., Hoekstra O.S., et al. Partial volume correction strategies for quantitative FDG PET in oncology. Eur J Nucl Med Mol Imaging 2010, 37:1679-1687.
    • (2010) Eur J Nucl Med Mol Imaging , vol.37 , pp. 1679-1687
    • Hoetjes, N.J.1    van Velden, F.H.2    Hoekstra, O.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.