메뉴 건너뛰기




Volumn 45, Issue , 2012, Pages 82-90

Thermal performance and cost effectiveness of wall insulation under Thai climate

Author keywords

Air conditioning; Cooling load; Vernacular buildings; Wall insulation; Wall performance

Indexed keywords

AIR-CONDITIONED SPACES; COOLING LOAD; COST EFFECTIVE; ECONOMIC PERFORMANCE; FORCED VENTILATION; INTERIOR SPACE; LARGE BUILDINGS; PUBLIC BUILDINGS; SIMULATION STUDIES; THAILAND; THERMAL MASS; THERMAL PERFORMANCE; WALL INSULATION; WALL PERFORMANCE;

EID: 84855240808     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2011.10.025     Document Type: Article
Times cited : (36)

References (19)
  • 1
    • 73049103159 scopus 로고    scopus 로고
    • Ancient vernacular architecture: Characteristics categorization and energy performance evaluation
    • Z. Zhai, and J.M. Previtali Ancient vernacular architecture: characteristics categorization and energy performance evaluation Energy and Buildings 42 2010 357 365
    • (2010) Energy and Buildings , vol.42 , pp. 357-365
    • Zhai, Z.1    Previtali, J.M.2
  • 2
    • 0037332442 scopus 로고    scopus 로고
    • Optimum insulation thickness of external walls for energy saving
    • K. Comakli, and B. Yuksel Optimum insulation thickness of external walls for energy saving Applied Thermal Engineering 23 2003 473 479
    • (2003) Applied Thermal Engineering , vol.23 , pp. 473-479
    • Comakli, K.1    Yuksel, B.2
  • 3
    • 4344649124 scopus 로고    scopus 로고
    • Determination and selecting the optimum thickness of insulation for buildings in hot countries by accounting for solar radiation
    • M.J. Khawaja Determination and selecting the optimum thickness of insulation for buildings in hot countries by accounting for solar radiation Applied Thermal Engineering 24 2004 2601 2610
    • (2004) Applied Thermal Engineering , vol.24 , pp. 2601-2610
    • Khawaja, M.J.1
  • 4
    • 10444272493 scopus 로고    scopus 로고
    • Cooling energy evaluation for high-rise residential buildings in Hong Kong
    • M. Bojic, and F. Yik Cooling energy evaluation for high-rise residential buildings in Hong Kong Energy and Buildings 37 2005 345 351
    • (2005) Energy and Buildings , vol.37 , pp. 345-351
    • Bojic, M.1    Yik, F.2
  • 5
    • 33745134436 scopus 로고    scopus 로고
    • Optimization of insulation thickness for external walls using different energy-sources
    • DOI 10.1016/j.apenergy.2005.10.006, PII S0306261905001364
    • O.A. Dombayci, M. Golcu, and Y. Pancar Optimization of insulation thickness for external walls using different energy sources Applied Energy 83 2006 921 928 (Pubitemid 43903092)
    • (2006) Applied Energy , vol.83 , Issue.9 , pp. 921-928
    • Dombayci, O.A.1    Golcu, M.2    Pancar, Y.3
  • 6
    • 34447127038 scopus 로고    scopus 로고
    • The environmental impact of optimum insulation thickness for external walls of buildings
    • DOI 10.1016/j.buildenv.2006.10.054, PII S0360132306003969
    • O.A. Dombayci The environmental impact of optimum insulation thickness for external walls of buildings Building and Environment 42 2007 3855 3859 (Pubitemid 47034811)
    • (2007) Building and Environment , vol.42 , Issue.11 , pp. 3855-3859
    • Dombayci, O.A.1
  • 7
    • 38849104230 scopus 로고    scopus 로고
    • Optimum insulation thicknesses for building walls with respect to cooling and heating degree-hours in the warmest zone of Turkey
    • DOI 10.1016/j.buildenv.2007.02.014, PII S036013230700090X
    • A. Bolatturk Optimum insulation thicknesses for building walls with respect to cooling and heating degree-hours in the warmest zone of Turkey Building and Environment 43 2008 1055 1064 (Pubitemid 351194257)
    • (2008) Building and Environment , vol.43 , Issue.6 , pp. 1055-1064
    • Bolatturk, A.1
  • 9
    • 77950459074 scopus 로고    scopus 로고
    • Cost benefit analysis and emission reductions of optimum thickness and air gaps for selected insulation materials for building walls in Maldives
    • T.M.I. Mahlia, and A. Iqbal Cost benefit analysis and emission reductions of optimum thickness and air gaps for selected insulation materials for building walls in Maldives Energy 35 2010 2242 2250
    • (2010) Energy , vol.35 , pp. 2242-2250
    • Mahlia, T.M.I.1    Iqbal, A.2
  • 10
    • 67349133107 scopus 로고    scopus 로고
    • A study on optimum insulation thicknesses of external walls in hot summer and cold winter zone of China
    • J. Yu, C. Yang, L. Tian, and D. Liao A study on optimum insulation thicknesses of external walls in hot summer and cold winter zone of China Applied Energy 86 2009 2520 2529
    • (2009) Applied Energy , vol.86 , pp. 2520-2529
    • Yu, J.1    Yang, C.2    Tian, L.3    Liao, D.4
  • 11
    • 69449102747 scopus 로고    scopus 로고
    • Determination of the energy savings and the optimum insulation thickness in the four different insulated exterior walls
    • A. Uker, and F. Balo Determination of the energy savings and the optimum insulation thickness in the four different insulated exterior walls Renewable Energy 35 2010 88 94
    • (2010) Renewable Energy , vol.35 , pp. 88-94
    • Uker, A.1    Balo, F.2
  • 12
    • 0035400743 scopus 로고    scopus 로고
    • Influence of thermal insulation position in building envelope on the space cooling of high-rise residential buildings in Hong Kong
    • DOI 10.1016/S0378-7788(00)00125-0, PII S0378778800001250
    • M. Bojic, F. Yik, and P. Sat Influence of thermal insulation position in building envelope on the space cooling of high-rise buildings in Hong Kong Energy and Buildings 33 2001 569 581 (Pubitemid 32446639)
    • (2001) Energy and Buildings , vol.33 , Issue.6 , pp. 569-581
    • Bojic, M.1    Yik, F.2    Sat, P.3
  • 13
    • 0036027474 scopus 로고    scopus 로고
    • Thermal insulation of cooled spaces in high rise residential buildings in Hong Kong
    • DOI 10.1016/S0196-8904(01)00018-8, PII S0196890401000188
    • M. Bojic, F. Yik, and W. Leung Thermal insulation of cooled spaces in high rise residential buildings in Hong Kong Energy Conversion and Management 43 2002 165 183 (Pubitemid 33039149)
    • (2002) Energy Conversion and Management , vol.43 , Issue.2 , pp. 165-183
    • Bojic, M.1    Yik, F.2    Leung, W.3
  • 14
    • 0036532684 scopus 로고    scopus 로고
    • Influence of insulation configuration on heating and cooling loads in a continuously used building
    • DOI 10.1016/S0378-7788(01)00121-9, PII S0378778801001219
    • M. Kossecka, and J. Kosny Influence of insulation configuration on heating and cooling loads in a continuously used buildings Energy and Buildings 34 2002 321 331 (Pubitemid 34086552)
    • (2002) Energy and Buildings , vol.34 , Issue.4 , pp. 321-331
    • Kossecka, E.1    Kosny, J.2
  • 15
    • 41749121950 scopus 로고    scopus 로고
    • Transient analysis of an external building cladding
    • DOI 10.1016/j.enbuild.2007.11.008, PII S0378778807002708
    • C. Balocco, G. Grazzini, and A. Cavalera Transient analysis of an external building cladding Energy and Buildings 40 2008 1273 1277 (Pubitemid 351491545)
    • (2008) Energy and Buildings , vol.40 , Issue.7 , pp. 1273-1277
    • Balocco, C.1    Grazzini, G.2    Cavalera, A.3
  • 16
    • 48949115592 scopus 로고    scopus 로고
    • A new and innovative look at anti-insulation behaviour in building energy consumption
    • O.T. Masoso, and L.J. Grobler A new and innovative look at anti-insulation behaviour in building energy consumption Energy and Buildings 40 2008 1889 1894
    • (2008) Energy and Buildings , vol.40 , pp. 1889-1894
    • Masoso, O.T.1    Grobler, L.J.2
  • 17
    • 79956374363 scopus 로고    scopus 로고
    • Thermal performance and cost effectiveness of massive walls under Thai climate
    • S. Chirarattananon, and V.D. Hien Thermal performance and cost effectiveness of massive walls under Thai climate Energy and Buildings 43 2011 1655 1662
    • (2011) Energy and Buildings , vol.43 , pp. 1655-1662
    • Chirarattananon, S.1    Hien, V.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.