1
-
-
84855162935
-
-
Global Observatory on Donation & Transplantation (online) (accessed 11 / 08 / 10)
-
Global Observatory on Donation & Transplantation. http://www.transplant-observatory.org (online) (accessed 11 / 08 / 10)
-
-
-
-
2
-
-
84855178225
-
-
National Kidney Foundation (online)(accessed 26 / 03 / 10)
-
National Kidney Foundation. http://www.kidney.org.uk/campaigns/ Press-Media/nkf-press-oct06.html (online)(accessed 26 / 03 / 10)
-
-
-
-
3
-
-
58249089430
-
Machine Perfusion or Cold Storage in Deceased-Donor Kidney Transplantation
-
Moers C, Smits J M., Maathuis M J. Machine Perfusion or Cold Storage in Deceased-Donor Kidney Transplantation. N Engl J Med 2009 360 7-19
-
(2009)
N Engl J Med
, vol.360
, pp. 7-19
-
-
Moers, C.1
Smits, J.M.2
Maathuis, M.J.3
-
4
-
-
0042693018
-
Experiences learned in the successful establishment of a nonheart beating donor program for renal transplantation
-
DOI 10.1097/01.ju.0000086774.12582.0f
-
Talbot D, Shenton B K., Buckley P E. et al. Experiences learned in the successful establishment of a nonheart beating donor program for renal transplantation. J Urology 2003 170 1088-1092 (Pubitemid 37108085)
-
(2003)
Journal of Urology
, vol.170
, Issue.4
, pp. 1088-1092
-
-
Talbot, D.1
Shenton, B.K.2
Buckley, P.E.3
Gok, M.A.4
-
5
-
-
78049462546
-
Renal Damage Caused by Warm Ischaemia during Laparoscopic and Robot- Assisted Partial Nephrectomy: An Assessment Using Tc 99m-DTPA Glomerular Filtration Rate
-
Choi J D. et al. Renal Damage Caused by Warm Ischaemia During Laparoscopic and Robot- Assisted Partial Nephrectomy: An Assessment Using Tc 99m-DTPA Glomerular Filtration Rate. Eur Urol 2010
-
(2010)
Eur Urol
-
-
Choi, J.D.1
-
6
-
-
0036226158
-
Contrast-enhanced sonography of the renal transplant using triggered pulse-inversion imaging: Preliminary results
-
DOI 10.1016/S0301-5629(01)00526-9, PII S0301562901005269
-
Lefèvre F, Correas J M., Briançon S. Contrast-enhanced sonography of the renal transplant using triggered pulse-inversion imaging: preliminary results. Ultrasound Med Biol 2002 28 303-314 (Pubitemid 34308910)
-
(2002)
Ultrasound in Medicine and Biology
, vol.28
, Issue.3
, pp. 303-314
-
-
Lefevre, F.1
Correas, J.M.2
Briancon, S.3
Helenon, O.4
Kessler, M.5
Claudon, M.6
-
7
-
-
50849134868
-
Arrival time parametric imaging: A new ultrasound technique for quantifying perfusion of kidney grafts
-
Fischer T, Filimonow S, Rudolph J. Arrival time parametric imaging: a new ultrasound technique for quantifying perfusion of kidney grafts. Ultraschall in Med 2008 29 418-423
-
(2008)
Ultraschall in Med
, vol.29
, pp. 418-423
-
-
Fischer, T.1
Filimonow, S.2
Rudolph, J.3
-
8
-
-
70349728220
-
Ultrasonic microbubble contrast agents and the transplant kidney
-
Kay D H., Mazonakis C, Geddes C et al. Ultrasonic microbubble contrast agents and the transplant kidney. Clin Radiol 2009 64 1081-1087
-
(2009)
Clin Radiol
, vol.64
, pp. 1081-1087
-
-
Kay, D.H.1
Mazonakis, C.2
Geddes, C.3
-
9
-
-
77952095173
-
Diagnosis of gallbladder problems using three-dimensional ultrasound
-
Stenberg B, Elliott S T. Diagnosis of gallbladder problems using three-dimensional ultrasound. Eur Radiol 2010 20 908-914
-
(2010)
Eur Radiol
, vol.20
, pp. 908-914
-
-
Stenberg, B.1
Elliott, S.T.2
-
10
-
-
33749611045
-
Improved diagnosis of early kidney allograft dysfunction by ultrasound with echo enhancer - A new method for the diagnosis of renal perfusion
-
DOI 10.1093/ndt/gfl313
-
Fischer T, Filimonow S, Dieckhöfer J. Improved diagnosis of early kidney allograft dysfunction by ultrasound with echo enhancer a new method for the diagnosis of renal perfusion. Nephrol Dial Transplant 2006 21 2921-2929 (Pubitemid 44542251)
-
(2006)
Nephrology Dialysis Transplantation
, vol.21
, Issue.10
, pp. 2921-2929
-
-
Fischer, T.1
Filimonow, S.2
Dieckhofer, J.3
Slowinski, T.4
Muhler, M.5
Lembcke, A.6
Budde, K.7
Neumayer, H.-H.8
Ebeling, V.9
Giessing, M.10
Thomas, A.11
Morgera, S.12
-
11
-
-
70349728220
-
Ultrasonic microbubble contrast agents and the transplant kidney
-
Kay D H., Mazonakis C, Geddes C et al. Ultrasonic microbubble contrast agents and the transplant kidney. Clin Radiol 2009 64 1081-1087
-
(2009)
Clin Radiol
, vol.64
, pp. 1081-1087
-
-
Kay, D.H.1
Mazonakis, C.2
Geddes, C.3
-
12
-
-
58149092572
-
Ischemic Injury to Kidney Induces Glomerular Podocyte Effacement and Dissociation of Slit Diaphragm Proteins Neph1 and ZO-1
-
Wagner M, Rhodes G, Wang C et al. Ischemic Injury to Kidney Induces Glomerular Podocyte Effacement and Dissociation of Slit Diaphragm Proteins Neph1 and ZO-1. Journal of Biological Chemistry 2008 283 35 579-35 589
-
(2008)
Journal of Biological Chemistry
, vol.283
, pp. 35579-35589
-
-
Wagner, M.1
Rhodes, G.2
Wang, C.3
-
14
-
-
67349165383
-
Rapid 3-D imaging of contrast flow: Application in a perfused kidney phantom
-
Chen N G., Fowlkes J B., Carson P L. et al. Rapid 3-D imaging of contrast flow: application in a perfused kidney phantom. Ultrasound med biol 2009 35 813-828
-
(2009)
Ultrasound Med Biol
, vol.35
, pp. 813-828
-
-
Chen, N.G.1
Fowlkes, J.B.2
Carson, P.L.3
-
17
-
-
55749103204
-
In Situ Kidney Insonation with Microbubble Contrast Agents Does Not Cause Renal Tissue Damage in a Porcine Model
-
Jimenez C, Gracia R de, Aguilera A. In Situ Kidney Insonation With Microbubble Contrast Agents Does Not Cause Renal Tissue Damage in a Porcine Model. J Ultrasound Med 2008 27 1607-1615
-
(2008)
J Ultrasound Med
, vol.27
, pp. 1607-1615
-
-
Jimenez, C.1
De, G.R.2
Aguilera, A.3
-
18
-
-
77958183532
-
Contrast-enhanced diagnostic ultrasound causes renal tissue damage in a porcine model
-
Miller D J., Dou C, Wiggins R C. Contrast-enhanced diagnostic ultrasound causes renal tissue damage in a porcine model. J Ultrasound Med 2010 29 (10) 1391-1401
-
(2010)
J Ultrasound Med
, vol.29
, Issue.10
, pp. 1391-1401
-
-
Miller, D.J.1
Dou, C.2
Wiggins, R.C.3
|