Volumn 204, Issue 1, 2012, Pages 118-123

A comparison of MR imaging of a mouse model of glioma at 0.2T and 9.4T

Author keywords

Brain; Glioma; Low field MRI; MRI; RF coil

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; BRAIN SLICE; BRAIN TISSUE; COMPARATIVE STUDY; GLIOMA; HUMAN; HUMAN CELL; MALE; MOUSE; NONHUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL;

EID: 84855171864     PISSN: 01650270     EISSN: 1872678X     Source Type: Journal    
DOI: 10.1016/j.jneumeth.2011.10.030     Document Type: Article
Times cited : (5)

References (28)
  • 1
    • 0032470994 scopus 로고    scopus 로고
    • Magnetic resonance diagnosis of the anterior labrum and capsule. Effect of field strength on efficacy
    • Allmann K.H., Walter O., Laubenberger J., Uhl M., Buitago-Tellez C.H., Biebow N., et al. Magnetic resonance diagnosis of the anterior labrum and capsule. Effect of field strength on efficacy. Invest Radiol 1998, 33:415-420.
    • (1998) Invest Radiol , vol.33 , pp. 415-420
    • Allmann, K.H.1    Walter, O.2    Laubenberger, J.3    Uhl, M.4    Buitago-Tellez, C.H.5    Biebow, N.6
  • 2
    • 0027171844 scopus 로고
    • MR diagnosis of internal derangement of the knee: effect of field strength on efficacy
    • Barnettt J. MR diagnosis of internal derangement of the knee: effect of field strength on efficacy. Am J Roentgenol 1993, 161:1115-1118.
    • (1993) Am J Roentgenol , vol.161 , pp. 1115-1118
    • Barnettt, J.1
  • 4
    • 70349808224 scopus 로고    scopus 로고
    • An optimized solenoidal head radiofrequency coil for low-field magnetic resonance imaging
    • Blasiak B., Volotovskyy V., Deng C., Tomanek B. An optimized solenoidal head radiofrequency coil for low-field magnetic resonance imaging. Magn Reson Imaging 2009, 27:1302-1308.
    • (2009) Magn Reson Imaging , vol.27 , pp. 1302-1308
    • Blasiak, B.1    Volotovskyy, V.2    Deng, C.3    Tomanek, B.4
  • 5
    • 0031305015 scopus 로고    scopus 로고
    • MR equipment acquisition strategies: low field or high field scanners
    • Bonart M.L., Kormaro M. MR equipment acquisition strategies: low field or high field scanners. Eur Radiol 1997, 7:263-268.
    • (1997) Eur Radiol , vol.7 , pp. 263-268
    • Bonart, M.L.1    Kormaro, M.2
  • 6
    • 77949659175 scopus 로고    scopus 로고
    • In vivo preclinical low field MRI monitoring of tumor growth following a suicide gene therapy in an orthotopic mice model of human glioblastoma
    • Breton E., Goetz C., Kintz J., Accart N., Aubertin G., Grellier B., et al. In vivo preclinical low field MRI monitoring of tumor growth following a suicide gene therapy in an orthotopic mice model of human glioblastoma. C R Biol 2010, 333:220-225.
    • (2010) C R Biol , vol.333 , pp. 220-225
    • Breton, E.1    Goetz, C.2    Kintz, J.3    Accart, N.4    Aubertin, G.5    Grellier, B.6
  • 7
    • 0022799215 scopus 로고
    • The field dependance of NMR imaging. 1. Laboratory assessment of signal to noise ratio and power deposition
    • Chen C.N., Sank V.J., Hoult D.I. The field dependance of NMR imaging. 1. Laboratory assessment of signal to noise ratio and power deposition. Magn Reson Med 1986, 3:722-729.
    • (1986) Magn Reson Med , vol.3 , pp. 722-729
    • Chen, C.N.1    Sank, V.J.2    Hoult, D.I.3
  • 11
    • 17544396674 scopus 로고    scopus 로고
    • Anxiety of MR patients extends beyond claustrophobia
    • Evers S.R. Anxiety of MR patients extends beyond claustrophobia. Diagn Imaging (San Franc) 1999, 21:41-48.
    • (1999) Diagn Imaging (San Franc) , vol.21 , pp. 41-48
    • Evers, S.R.1
  • 14
    • 46549092488 scopus 로고
    • An efficient, highly homogenous radiofrequency coil for whole-body NMR imaging at 1.5T
    • Hayes C.E., Edelstein W.A., Schenck J.F., Mueller O.M., Eash M. An efficient, highly homogenous radiofrequency coil for whole-body NMR imaging at 1.5T. J Magn Reson 1985, 63:622-628.
    • (1985) J Magn Reson , vol.63 , pp. 622-628
    • Hayes, C.E.1    Edelstein, W.A.2    Schenck, J.F.3    Mueller, O.M.4    Eash, M.5
  • 15
    • 0022799736 scopus 로고
    • The field dependent of NMR imaging. II. Arguments concerning an optimal field strength
    • Hoult D.I., Chen C.N., Sank V.J. The field dependent of NMR imaging. II. Arguments concerning an optimal field strength. Magn Reson Med 1986, 3:730-746.
    • (1986) Magn Reson Med , vol.3 , pp. 730-746
    • Hoult, D.I.1    Chen, C.N.2    Sank, V.J.3
  • 16
    • 49549133678 scopus 로고
    • The signal-to-noise ratio of the magnetic resonance experiment
    • Hoult D.I., Richards R.E. The signal-to-noise ratio of the magnetic resonance experiment. J Magn Reson 1976, 24:71-85.
    • (1976) J Magn Reson , vol.24 , pp. 71-85
    • Hoult, D.I.1    Richards, R.E.2
  • 17
    • 0033945956 scopus 로고    scopus 로고
    • Sensitivity and power deposition in a high-field imaging experiment
    • Hoult D.I. Sensitivity and power deposition in a high-field imaging experiment. J Magn Reson Imaging 2000, 12:46-67.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 46-67
    • Hoult, D.I.1
  • 19
    • 0029079320 scopus 로고
    • MR mammography at 0.5 Tesla. II. The capacity to differentiate malignant and benign lesions in MR mammography at 0. 5 and 1. 5T
    • Kuhl C.K., Kreft B.P., Hauswirth A., Geiseke J., Elevelt A., Reiser M., et al. MR mammography at 0.5 Tesla. II. The capacity to differentiate malignant and benign lesions in MR mammography at 0. 5 and 1. 5T. Roto Fortschr Geb Roengenstr Neuen Verfahr 1995, 162:482-491.
    • (1995) Roto Fortschr Geb Roengenstr Neuen Verfahr , vol.162 , pp. 482-491
    • Kuhl, C.K.1    Kreft, B.P.2    Hauswirth, A.3    Geiseke, J.4    Elevelt, A.5    Reiser, M.6
  • 20
    • 6044249967 scopus 로고
    • Paramagnetic metal complexes as water proton relaxation agents for NMR imaging: theory and design
    • Lauffer R.B. Paramagnetic metal complexes as water proton relaxation agents for NMR imaging: theory and design. Chem Rev 1987, 87(5):901-927.
    • (1987) Chem Rev , vol.87 , Issue.5 , pp. 901-927
    • Lauffer, R.B.1
  • 21
    • 0003382599 scopus 로고    scopus 로고
    • Interventional MRI with an open low-field system
    • Springer-Verlang, Berlin, J.F. Debatin, G. Adams (Eds.)
    • Lenz G., Drobnitzky M. Interventional MRI with an open low-field system. Interventional magnetic resonance imaging 1998, 3-10. Springer-Verlang, Berlin. J.F. Debatin, G. Adams (Eds.).
    • (1998) Interventional magnetic resonance imaging , pp. 3-10
    • Lenz, G.1    Drobnitzky, M.2
  • 22
    • 0033050451 scopus 로고    scopus 로고
    • Results of a prospective multicenter study for evaluation of the diagnostic quality of an open whole-body low-field MRI unit. A comparison with high-field MRI measured by the applicable gold standard
    • Merl T., Scholz M., Gerhardt P., Langer M., Laubenberger J., Weiss H.D., et al. Results of a prospective multicenter study for evaluation of the diagnostic quality of an open whole-body low-field MRI unit. A comparison with high-field MRI measured by the applicable gold standard. Eur J Radiol 1999, 30:43-53.
    • (1999) Eur J Radiol , vol.30 , pp. 43-53
    • Merl, T.1    Scholz, M.2    Gerhardt, P.3    Langer, M.4    Laubenberger, J.5    Weiss, H.D.6
  • 25
    • 0000314521 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the extremities using dedicated equipment: diagnostic and economic considerations
    • Passariello R., Mastantuono M., Satraggno L. Magnetic resonance imaging of the extremities using dedicated equipment: diagnostic and economic considerations. Acad Radiol 1996, 3:141-144.
    • (1996) Acad Radiol , vol.3 , pp. 141-144
    • Passariello, R.1    Mastantuono, M.2    Satraggno, L.3
  • 26
    • 0034067374 scopus 로고    scopus 로고
    • MRI of the claustrophobic patient: interventionally configured magnet
    • Spouse E., Gedroyc W.M. MRI of the claustrophobic patient: interventionally configured magnet. Br J Radiol 2000, 73:918-923.
    • (2000) Br J Radiol , vol.73 , pp. 918-923
    • Spouse, E.1    Gedroyc, W.M.2
  • 27
    • 0032438507 scopus 로고    scopus 로고
    • Brain tumor survival: results from the National Cancer Data Base
    • Surawicz T.S., Davis F., Freels S., Laws E.R., Menck H.R. Brain tumor survival: results from the National Cancer Data Base. J Neurooncol 1998, 40(2):151-160.
    • (1998) J Neurooncol , vol.40 , Issue.2 , pp. 151-160
    • Surawicz, T.S.1    Davis, F.2    Freels, S.3    Laws, E.R.4    Menck, H.R.5
  • 28
    • 0026582853 scopus 로고
    • Experimental design and fabrication of birdcage resonators for magnetic resonance imaging
    • Vullo T., Zipagan R.T., Pascone R., Whalen J.P., Cahill P.T. Experimental design and fabrication of birdcage resonators for magnetic resonance imaging. Magn Reson Med 1992, 24(2):243-252.
    • (1992) Magn Reson Med , vol.24 , Issue.2 , pp. 243-252
    • Vullo, T.1    Zipagan, R.T.2    Pascone, R.3    Whalen, J.P.4    Cahill, P.T.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.