메뉴 건너뛰기




Volumn 25, Issue 6, 2011, Pages 377-385

Impact of central hypovolemia on photoplethysmographic waveform parameters in healthy volunteers. Part 1: Time domain Analysis

Author keywords

non invasive monitoring; photoplethysmography; pulse oximeter; waveform analysis

Indexed keywords

ARTERIAL BLOOD PRESSURE; BLOOD FLOW; BLOOD LOSS; DIASTOLIC PRESSURE; HEART RATE VARIABILITY; HEART RATES; LOWER BODY; NEGATIVE PRESSURES; NON-INVASIVE MONITORING; PHOTOPLETHYSMOGRAPHIC; PHOTOPLETHYSMOGRAPHY; PRESSURE VARIABLES; PULSE OXIMETERS; PULSE PRESSURE; SQUARE ROOTS; WAVE FORMS; WAVEFORM PARAMETERS; WILCOXON TEST;

EID: 84655168074     PISSN: 13871307     EISSN: 15732614     Source Type: Journal    
DOI: 10.1007/s10877-011-9316-y     Document Type: Article
Times cited : (18)

References (25)
  • 1
    • 15544387799 scopus 로고    scopus 로고
    • Perioperative fluid management and clinical outcomes in adults
    • DOI 10.1213/01.ANE.0000148691.33690.AC
    • MPW Grocott G Michael MG Mythen TJ Gan 2005 Perioperative fluid management and clinical outcome in adults Anesth Analg 100 1093 1106 15781528 10.1213/01.ANE.0000148691.33690.AC (Pubitemid 40404217)
    • (2005) Anesthesia and Analgesia , vol.100 , Issue.4 , pp. 1093-1106
    • Grocott, M.P.W.1    Mythen, M.G.2    Gan, T.J.3
  • 3
    • 1642293151 scopus 로고    scopus 로고
    • Lower body negative pressure as a model to study progression to acute hemorrhagic shock in humans
    • DOI 10.1152/japplphysiol.01155.2003
    • W Cooke K Ryan V Convertino 2004 Lower body negative pressure as a model to study progression to acute hemorrhagic shock in humans J Appl Physiol 96 4 1249 1261 15016789 10.1152/japplphysiol.01155.2003 (Pubitemid 38392658)
    • (2004) Journal of Applied Physiology , vol.96 , Issue.4 , pp. 1249-1261
    • Cooke, W.H.1    Ryan, K.L.2    Convertino, V.A.3
  • 4
    • 0035754432 scopus 로고    scopus 로고
    • Lower body negative pressure as a tool for research in aerospace physiology and military medicine
    • 12365445 1:STN:280:DC%2BD38nhtVajtg%3D%3D
    • VA Convertino 2001 Lower body negative pressure as a tool for research in aerospace physiology and military medicine J Gravit Physiol 8 2 1 14 12365445 1:STN:280:DC%2BD38nhtVajtg%3D%3D
    • (2001) J Gravit Physiol , vol.8 , Issue.2 , pp. 1-14
    • Convertino, V.A.1
  • 5
    • 0016247804 scopus 로고
    • Physiological effects of locally applied reduced pressure in man
    • 4601623 1:STN:280:DyaE2c3ntlWhtA%3D%3D
    • R Wolthuis S Bergman A Nicogossian 1974 Physiological effects of locally applied reduced pressure in man Physiol Rev 54 3 566 595 4601623 1:STN:280:DyaE2c3ntlWhtA%3D%3D
    • (1974) Physiol Rev , vol.54 , Issue.3 , pp. 566-595
    • Wolthuis, R.1    Bergman, S.2    Nicogossian, A.3
  • 8
    • 0016833628 scopus 로고
    • Response of local vascular volumes to lower body negative pressure stress
    • 1:STN:280:DyaE2M7msVentg%3D%3D
    • RA Wolthuis A LeBlanc WA Carpentier SA Bergman 1975 Response of local vascular volumes to lower body negative pressure stress Avit Space Environ Med 46 697 702 1:STN:280:DyaE2M7msVentg%3D%3D
    • (1975) Avit Space Environ Med , vol.46 , pp. 697-702
    • Wolthuis, R.A.1    Leblanc, A.2    Carpentier, W.A.3    Bergman, S.A.4
  • 9
    • 0014526035 scopus 로고
    • Changes in total leg voilume during lower body negative pressure
    • FS Muscrave FW Zechman RC Mains 1969 Changes in total leg voilume during lower body negative pressure Aerospace Med 40 602 606
    • (1969) Aerospace Med , vol.40 , pp. 602-606
    • Muscrave, F.S.1    Zechman, F.W.2    Mains, R.C.3
  • 10
    • 0001546460 scopus 로고
    • The absence of vasoconstrictor reflexes in the forehead circulation: Effects of cold
    • AB Hertzman LW Roth 1942 The absence of vasoconstrictor reflexes in the forehead circulation: effects of cold Am J Physiol 136 692 697
    • (1942) Am J Physiol , vol.136 , pp. 692-697
    • Hertzman, A.B.1    Roth, L.W.2
  • 11
    • 0035024813 scopus 로고    scopus 로고
    • Different responses of ear and finger pulse oximeter wave form to cold pressor test
    • A Awad MA Ghobashy W Ouda RG Stout DG Silverman KH Shelley 2001 Different responses of ear and finger pulse oximeter wave form to cold pressor test Anesth Analg 92 6 1483 1486 11375830 10.1097/00000539-200106000-00026 1:STN:280:DC%2BD3M3pt12lsw%3D%3D (Pubitemid 32493167)
    • (2001) Anesthesia and Analgesia , vol.92 , Issue.6 , pp. 1483-1486
    • Awad, A.A.1    Ghobashy, M.A.M.2    Ouda, W.3    Stout, R.G.4    Silverman, D.G.5    Shelley, K.H.6
  • 12
    • 0020956492 scopus 로고
    • Evaluation of pulse oximetry
    • M Yelderman W New 1983 Evaluation of pulse oximetry Anesthesiology 59 4 349 352 6614545 10.1097/00000542-198310000-00015 1:STN:280:DyaL3szgs1KlsA%3D%3D (Pubitemid 13012527)
    • (1983) Anesthesiology , vol.59 , Issue.4 , pp. 349-352
    • Yelderman, M.1    New Jr., W.2
  • 13
    • 43449105997 scopus 로고    scopus 로고
    • Photoplethysmography: Beyond the calculation of arterial oxygen saturation and heart rate
    • 18048895 10.1213/01.ane.0000269512.82836.c9
    • KH Shelley 2007 Photoplethysmography: beyond the calculation of arterial oxygen saturation and heart rate Anesth Analg 105 6 Suppl S31 S36 18048895 10.1213/01.ane.0000269512.82836.c9
    • (2007) Anesth Analg , vol.105 , Issue.6 SUPPL.
    • Shelley, K.H.1
  • 15
    • 0025327294 scopus 로고
    • Heart rate and muscle sympathetic nerve variability during reflex changes of autonomic activity
    • 2316686 1:STN:280:DyaK3c7ps1ejsw%3D%3D
    • JP Saul RF Rea DL Eckberg RD Berger RJ Cohen 1990 Heart rate and muscle sympathetic nerve variability during reflex changes of autonomic activity Am J Physiol 258 H713 H721 2316686 1:STN:280:DyaK3c7ps1ejsw%3D%3D
    • (1990) Am J Physiol , vol.258
    • Saul, J.P.1    Rea, R.F.2    Eckberg, D.L.3    Berger, R.D.4    Cohen, R.J.5
  • 16
    • 0029928495 scopus 로고    scopus 로고
    • Task force of the European society of cardiology and the North American society of pacing and electrophysiology
    • Heart rate variability: standards of measurement, physiological interpretation, clinical use. 10.1161/01.CIR.93.5.1043
    • Heart rate variability: standards of measurement, physiological interpretation, clinical use 1996 Task force of the European society of cardiology and the North American society of pacing and electrophysiology Circulation 93 5 1043 1065 10.1161/01.CIR.93.5.1043
    • (1996) Circulation , vol.93 , Issue.5 , pp. 1043-1065
  • 17
    • 0023428633 scopus 로고
    • Use of pulse oximetry as a noninvasive indicator of intravascular volume status
    • 3681360 1:STN:280:DyaL1c%2FmtFCltw%3D%3D
    • BL Partridge 1987 Use of pulse oximetry as a noninvasive indicator of intravascular volume status J Clin Monit 3 4 263 268 3681360 1:STN:280:DyaL1c%2FmtFCltw%3D%3D
    • (1987) J Clin Monit , vol.3 , Issue.4 , pp. 263-268
    • Partridge, B.L.1
  • 18
    • 0032953278 scopus 로고    scopus 로고
    • Pulse oximetry plethysmographic waveform during changes in blood volume
    • M Shamir LA Eidelman Y Floman L Kaplan R Pizov 1999 Pulse oximetry plethysmographic waveform during changes in blood volume Br J Anaesth 82 2 178 181 10364990 10.1093/bja/82.2.178 1:STN:280:DyaK1M3ptlehtg%3D%3D (Pubitemid 29057612)
    • (1999) British Journal of Anaesthesia , vol.82 , Issue.2 , pp. 178-181
    • Shamir, M.1    Eidelman, L.A.2    Floman, Y.3    Kaplan, L.4    Pizov, R.5
  • 19
    • 0035201939 scopus 로고    scopus 로고
    • How does the plethysmogram derived from the pulse oximeter relate to arterial blood pressure in coronary artery bypass graft patients?
    • A Awad MA Ghobashy RG Stout DG Silverman KH Shelley 2001 How does the plethysmogram derived from the pulse oximeter relate to arterial blood pressure in coronary artery bypass graft patients? Anesth Analg 93 6 1466 1471 11726424 10.1097/00000539-200112000-00022 1:STN:280:DC%2BD3MnotVWitw%3D%3D (Pubitemid 33111670)
    • (2001) Anesthesia and Analgesia , vol.93 , Issue.6 , pp. 1466-1471
    • Awad, A.A.1    Ghobashy, M.A.M.2    Stout, R.G.3    Silverman, D.G.4    Shelley, K.H.5
  • 21
    • 79251542037 scopus 로고    scopus 로고
    • Pulse oximeter plethysmographic waveform changes in awake, spontaneously breathing, hypovolemic vol- unteers
    • 20103539 10.1213/ANE.0b013e3181cb3f4a
    • SP McGrath KL Ryan SM Wendelken CA Rickards VA Convertino 2011 Pulse oximeter plethysmographic waveform changes in awake, spontaneously breathing, hypovolemic vol- unteers Anesth Analg 112 2 368 374 20103539 10.1213/ANE.0b013e3181cb3f4a
    • (2011) Anesth Analg , vol.112 , Issue.2 , pp. 368-374
    • McGrath, S.P.1    Ryan, K.L.2    Wendelken, S.M.3    Rickards, C.A.4    Convertino, V.A.5
  • 22
    • 0026023118 scopus 로고
    • Hemodynamic and neurohumoral responses to acute hypovolemia in conscious mammals
    • 1671735 1:CAS:528:DyaK3MXhs1Wks7Y%3D
    • JC Schadt J Ludbrook 1991 Hemodynamic and neurohumoral responses to acute hypovolemia in conscious mammals Am J Physiol 260 H305 H318 1671735 1:CAS:528:DyaK3MXhs1Wks7Y%3D
    • (1991) Am J Physiol , vol.260
    • Schadt, J.C.1    Ludbrook, J.2
  • 23
    • 0014277712 scopus 로고
    • Role of the capacitance and resistance vessels in vasovagal syncope
    • 5649078 1:STN:280:DyaF1c3jslOlsQ%3D%3D
    • SE Epstein M Stampfer GD Beiser 1968 Role of the capacitance and resistance vessels in vasovagal syncope Circulation 37 524 533 5649078 1:STN:280:DyaF1c3jslOlsQ%3D%3D
    • (1968) Circulation , vol.37 , pp. 524-533
    • Epstein, S.E.1    Stampfer, M.2    Beiser, G.D.3
  • 24
    • 0036353483 scopus 로고    scopus 로고
    • Distinction between atropine-sensitive control of microvascular and cardiac oscillatory activity
    • DOI 10.1006/mvre.2001.2385
    • D Silverman R Stout 2002 Distinction between atropine-sensitive control of microvascular and cardiac oscillatory activity Microvasc Res 63 2 196 208 11866543 10.1006/mvre.2001.2385 (Pubitemid 34971636)
    • (2002) Microvascular Research , vol.63 , Issue.2 , pp. 196-208
    • Silverman, D.G.1    Stout, R.G.2
  • 25
    • 0021797791 scopus 로고
    • Photo-electric plethysmography as a monitoring device in anaesthesia. Application and interpretation
    • JC Dorlas JA Nijboer 1985 Photo-electric plethysmography as a monitoring device in anaesthesia. Application and interpretation Br J Anaesth 57 5 524 530 3994887 10.1093/bja/57.5.524 1:STN:280:DyaL2M7pvFGquw%3D%3D (Pubitemid 15052545)
    • (1985) British Journal of Anaesthesia , vol.57 , Issue.5 , pp. 524-530
    • Dorlas, J.C.1    Nijboer, J.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.