Volumn 26, Issue 4, 2011, Pages 797-806

Load fatigue performance of conical implant-abutment connections

Author keywords

Conical implant abutment connection; Implant abutment interface; Load fatigue

Indexed keywords

TITANIUM; ZIRCONIUM; ZIRCONIUM OXIDE;

EID: 84555206209     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (49)

References (39)
  • 1
    • 0030155754 scopus 로고    scopus 로고
    • Long-term stability of osseointegrated implants in bone regenerated with the membrane technique. 5-year results of a prospective study with 12 implants
    • Buser D, Dula K, Lang NP, Nyman S. Long-term stability of osseointegrated implants in bone regenerated with the membrane technique. 5-year results of a prospective study with 12 implants. Clin Oral Implants Res 1996;7:175-183.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 175-183
    • Buser, D.1    Dula, K.2    Lang, N.P.3    Nyman, S.4
  • 2
    • 2342431804 scopus 로고    scopus 로고
    • Long-term survival and success of oral implants in the treatment of full and partial arches: A seven-year prospective study with the ITI dental implant system
    • Romeo E, Lops D, Margutti E, Ghisolfi M, Chiapasco M, Vogel G. Long-term survival and success of oral implants in the treatment of full and partial arches: A seven-year prospective study with the ITI dental implant system. Int J Oral Maxillofac Implants 2004;19:247-259.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 247-259
    • Romeo, E.1    Lops, D.2    Margutti, E.3    Ghisolfi, M.4    Chiapasco, M.5    Vogel, G.6
  • 3
    • 0019663098 scopus 로고
    • A 15-year study of osseointegrated implants in the treatment of edentulous jaw
    • Adell R, Lekholm U, Rockler B, Brånemark P-I. A 15-year study of osseointegrated implants in the treatment of edentulous jaw. Int J Oral Surgery 1981;10:387-416.
    • (1981) Int J Oral Surgery , vol.10 , pp. 387-416
    • Adell, R.1    Lekholm, U.2    Rockler, B.3    Brånemark, P.-I.4
  • 4
    • 0034574104 scopus 로고    scopus 로고
    • Mechanical complications of dental implants
    • Schwarz MS. Mechanical complications of dental implants. Clin Oral Implants Res 2000;11(suppl):156-158.
    • (2000) Clin Oral Implants Res , vol.11 , pp. 156-158
    • Schwarz, M.S.1
  • 5
    • 0037928812 scopus 로고    scopus 로고
    • A systematic review of the incidence of biological and technical complications in implant dentistry reported in prospective longitudinal studies of at least 5 years
    • Berglundh T, Persson L, Klinge B. A systematic review of the incidence of biological and technical complications in implant dentistry reported in prospective longitudinal studies of at least 5 years. J Clin Periodontol 2002;29(suppl 3):197-212.
    • (2002) J Clin Periodontol , vol.29 , pp. 197-212
    • Berglundh, T.1    Persson, L.2    Klinge, B.3
  • 7
    • 37849054339 scopus 로고    scopus 로고
    • A systematic review of the 5 year survival and complication rates of implant-supported single crowns
    • Jung R, Pjetursson B, Glauser B, Zembic A, Zwahlen M, Lang N. A systematic review of the 5 year survival and complication rates of implant-supported single crowns. Clin Oral Implants Res 2008;19:119-130.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 119-130
    • Jung, R.1    Pjetursson, B.2    Glauser, B.3    Zembic, A.4    Zwahlen, M.5    Lang, N.6
  • 8
    • 0034218915 scopus 로고    scopus 로고
    • Mechanics of the implantabutment connection: An 8-degree taper compared to a butt joint connection
    • Merz BR, Hunenbart S, Belser UC. Mechanics of the implantabutment connection: An 8-degree taper compared to a butt joint connection. Int J Oral Maxillofac Implants 2000;15:519-526.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 519-526
    • Merz, B.R.1    Hunenbart, S.2    Belser, U.C.3
  • 9
    • 0034186179 scopus 로고    scopus 로고
    • In vitro evaluation of the strength of the conical implant-to-abutment joint in two commercially available implant systems
    • May
    • Norton MR. In vitro evaluation of the strength of the conical implant-to-abutment joint in two commercially available implant systems. J Prosthet Dent 2000 May;83:567-571.
    • (2000) J Prosthet Dent , vol.83 , pp. 567-571
    • Norton, M.R.1
  • 10
    • 0031197102 scopus 로고    scopus 로고
    • An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design
    • Norton MR. An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design. Clin Oral Implants Res 1997;8:290-298.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 290-298
    • Norton, M.R.1
  • 11
    • 34250709695 scopus 로고    scopus 로고
    • Peri-implant bone level around implants with platform-switched abutments:Preliminary data from a prospective study
    • Hurzeler M, FicklS, Zuhr O, Wachtel HC. Peri-implant bone level around implants with platform-switched abutments:Preliminary data from a prospective study. J Oral Maxillofac Surg 2007;65(suppl 1):33-39.
    • (2007) J Oral Maxillofac Surg , vol.65 , pp. 33-39
    • Hurzeler, M.1    Fickl, S.2    Zuhr, O.3    Wachtel, H.C.4
  • 12
    • 34250305399 scopus 로고    scopus 로고
    • Immediate provisionalization on a new implant design for esthetic restoration and preserving crestal bone
    • Guirado JLC, Yuguero MRS, Zamora GP, Barrio EM. Immediate provisionalization on a new implant design for esthetic restoration and preserving crestal bone. Implant Dent 2007; 16:155-164.
    • (2007) Implant Dent , vol.16 , pp. 155-164
    • Guirado, J.L.C.1    Yuguero, M.R.S.2    Zamora, G.P.3    Barrio, E.M.4
  • 14
    • 55749100339 scopus 로고    scopus 로고
    • Effect of microthreads and platform switching on crestal bone stress levels: A finite element analysis
    • Schrotenboer J, Tsao YP, Kinariwala V, Wang HL. Effect of microthreads and platform switching on crestal bone stress levels: A finite element analysis. J Periodontol 2008;79:2166-2172.
    • (2008) J Periodontol , vol.79 , pp. 2166-2172
    • Schrotenboer, J.1    Tsao, Y.P.2    Kinariwala, V.3    Wang, H.L.4
  • 15
    • 3242892644 scopus 로고    scopus 로고
    • Functional and esthetic considerations for single-tooth Ankylos implant-crowns: 8 years of clinical performance
    • Döring K, Eisenmann E, Stiller M. Functional and esthetic considerations for single-tooth Ankylos implant-crowns: 8 years of clinical performance. J Oral Implantol 2004;30:198-209.
    • (2004) J Oral Implantol , vol.30 , pp. 198-209
    • Döring, K.1    Eisenmann, E.2    Stiller, M.3
  • 16
    • 3242875522 scopus 로고    scopus 로고
    • New prosthetic restorative features of Ankylos implant system [review]
    • Weigl P. New prosthetic restorative features of Ankylos implant system [review]. J Oral Implantol 2004;30:178-188.
    • (2004) J Oral Implantol , vol.30 , pp. 178-188
    • Weigl, P.1
  • 17
    • 0141832052 scopus 로고    scopus 로고
    • Evaluation of the mechanical characteristics of the implant-abutment complex of a reduceddiameter Morse-taper implant. A nonlinear finite element stress analysis
    • Akça K, Cehreli MC, Iplikçioğlu H. Evaluation of the mechanical characteristics of the implant-abutment complex of a reduceddiameter Morse-taper implant. A nonlinear finite element stress analysis. Clin Oral Implants Res 2003;14:444-454.
    • (2003) Clin Oral Implants Res , vol.14 , pp. 444-454
    • Akça, K.1    Cehreli, M.C.2    Iplikçioğlu, H.3
  • 18
    • 34548700364 scopus 로고    scopus 로고
    • Biomechanical analysis on platform switching: Is there any biomechanical rationale?
    • Maeda Y, Miura J, Taki I, Sogo M. Biomechanical analysis on platform switching: Is there any biomechanical rationale? Clin Oral Implants Res 2007;18:581-584.
    • (2007) Clin Oral Implants Res , vol.18 , pp. 581-584
    • Maeda, Y.1    Miura, J.2    Taki, I.3    Sogo, M.4
  • 19
    • 0141923180 scopus 로고    scopus 로고
    • In vivo fracture resistance of implant-supported all-ceramic restorations
    • Yildirim M, Fischer H, Marx R, Edelhoff D. In vivo fracture resistance of implant-supported all-ceramic restorations. J Prosthet Dent 2003;90:325-331.
    • (2003) J Prosthet Dent , vol.90 , pp. 325-331
    • Yildirim, M.1    Fischer, H.2    Marx, R.3    Edelhoff, D.4
  • 20
    • 0029294802 scopus 로고
    • Strength and mode of failure of single implant all-ceramic abutment restorations under static load
    • Tripodakis AP, Strub JR, Kappert HF, Witkowski S. Strength and mode of failure of single implant all-ceramic abutment restorations under static load. Int J Prosthodont 1995;8:265-272.
    • (1995) Int J Prosthodont , vol.8 , pp. 265-272
    • Tripodakis, A.P.1    Strub, J.R.2    Kappert, H.F.3    Witkowski, S.4
  • 21
    • 27344446978 scopus 로고    scopus 로고
    • Survival rate, fracture strength and failure mode of ceramic implant abutments after chewing simulation
    • Butz F, Heydecke G, Okutan M, Strub JR. Survival rate, fracture strength and failure mode of ceramic implant abutments after chewing simulation. J Oral Rehabil 2005;32:838-843.
    • (2005) J Oral Rehabil , vol.32 , pp. 838-843
    • Butz, F.1    Heydecke, G.2    Okutan, M.3    Strub, J.R.4
  • 22
    • 33748509101 scopus 로고    scopus 로고
    • An in vitro evaluation of titanium, zirconia, and alumina Procera abutments with hexagonal connection
    • Vigolo P, Fonzi F, Majzoub Z, Cordioli G. An in vitro evaluation of titanium, zirconia, and alumina Procera abutments with hexagonal connection. Int J Oral Maxillofac Implants 2006; 21:575-580.
    • (2006) Int J Oral Maxillofac Implants , vol.21 , pp. 575-580
    • Vigolo, P.1    Fonzi, F.2    Majzoub, Z.3    Cordioli, G.4
  • 23
    • 66149129216 scopus 로고    scopus 로고
    • A comparison of fabrication precision and mechanical reliability of 2 zirconia implant abutments
    • Kerstein RB, Radke J. A comparison of fabrication precision and mechanical reliability of 2 zirconia implant abutments. Int J Oral Maxillofac Implants 2008;23:1029-1036.
    • (2008) Int J Oral Maxillofac Implants , vol.23 , pp. 1029-1036
    • Kerstein, R.B.1    Radke, J.2
  • 24
    • 58149134044 scopus 로고    scopus 로고
    • Fracture resistance of yttria-stabilized zirconia dental implant abutments
    • Adatia ND, Bayne SC, Cooper LF, Thompson JY. Fracture resistance of yttria-stabilized zirconia dental implant abutments. J Prosthodont 2009;18:17-22.
    • (2009) J Prosthodont , vol.18 , pp. 17-22
    • Adatia, N.D.1    Bayne, S.C.2    Cooper, L.F.3    Thompson, J.Y.4
  • 26
    • 0346851883 scopus 로고    scopus 로고
    • Evaluation of custom-made Procera ceramic abutments for single-implant tooth replacement: A prospective 1-year follow-up study
    • Henriksson K, Jemt T. Evaluation of custom-made Procera ceramic abutments for single-implant tooth replacement: A prospective 1-year follow-up study. Int J Prosthodont 2003; 16:626-630.
    • (2003) Int J Prosthodont , vol.16 , pp. 626-630
    • Henriksson, K.1    Jemt, T.2
  • 27
    • 0033154854 scopus 로고    scopus 로고
    • Ceramic implant abutments used for short-span fixed partial dentures: A prospective 2-year multicenter study
    • Andersson B, Scharer P, Simion M, Bergstrom C. Ceramic implant abutments used for short-span fixed partial dentures: A prospective 2-year multicenter study. Int J Prosthodont 1999; 12:318-324.
    • (1999) Int J Prosthodont , vol.12 , pp. 318-324
    • Andersson, B.1    Scharer, P.2    Simion, M.3    Bergstrom, C.4
  • 28
    • 0348112456 scopus 로고    scopus 로고
    • Ceramic implant abutments for short-span FPDs: A prospective 5-year multicenter study
    • Andersson B, Glauser R, Maglione M, Taylor A. Ceramic implant abutments for short-span FPDs: A prospective 5-year multicenter study. Int J Prosthodont 2003;16:640-646.
    • (2003) Int J Prosthodont , vol.16 , pp. 640-646
    • Andersson, B.1    Glauser, R.2    Maglione, M.3    Taylor, A.4
  • 29
    • 2542639442 scopus 로고    scopus 로고
    • Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions:4-year results of a prospective clinical study
    • Glauser R, Sailer I, Wohlwend A, Studer S, Schibli M, Schärer P. Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions:4-year results of a prospective clinical study. Int J Prosthodont 2004;17:285-290.
    • (2004) Int J Prosthodont , vol.17 , pp. 285-290
    • Glauser, R.1    Sailer, I.2    Wohlwend, A.3    Studer, S.4    Schibli, M.5    Schärer, P.6
  • 31
    • 33846290368 scopus 로고    scopus 로고
    • Load fatigue performance of a single-tooth implant abutment system: Effect of diameter
    • Quek CE, Tan KB, Nicholls JI. Load fatigue performance of a single-tooth implant abutment system: Effect of diameter. Int J Oral Maxillofac Implants 2006;21:929-936.
    • (2006) Int J Oral Maxillofac Implants , vol.21 , pp. 929-936
    • Quek, C.E.1    Tan, K.B.2    Nicholls, J.I.3
  • 32
    • 43149105399 scopus 로고    scopus 로고
    • Load fatigue performance of four implant-abutment interface designs: Effect of torque level and implant system
    • Quek HC, Tan KB, Nicholls JI. Load fatigue performance of four implant-abutment interface designs: Effect of torque level and implant system. Int J Oral Maxillofac Implants 2008;23:253-262.
    • (2008) Int J Oral Maxillofac Implants , vol.23 , pp. 253-262
    • Quek, H.C.1    Tan, K.B.2    Nicholls, J.I.3
  • 33
    • 0029262154 scopus 로고
    • Stress fatigue: Basic principles and prosthodontic implications
    • Wiskott HW, Nicholls JI, Belser UC. Stress fatigue: Basic principles and prosthodontic implications. Int J Prosthodont 1995;8:105-116.
    • (1995) Int J Prosthodont , vol.8 , pp. 105-116
    • Wiskott, H.W.1    Nicholls, J.I.2    Belser, U.C.3
  • 35
    • 84995745816 scopus 로고    scopus 로고
    • U.S. Department of Health and Human Services, Food and Drug Administration, Center for Devices and Radiological Health, Accessed 8 July
    • Class II special controls guidance document: Root-form endosseous dental implants and endosseous dental abutments 2004. U.S. Department of Health and Human Services, Food and Drug Administration, Center for Devices and Radiological Health. http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/ GuidanceDocuments/ucm072424.htm. Accessed 8 July 2011.
    • (2011) Class II special controls guidance document: Root-form endosseous dental implants and endosseous dental abutments 2004
  • 36
    • 35148891671 scopus 로고    scopus 로고
    • An overview of zirconia ceramics: Basic properties and clinical applications
    • Manicone PF, Iommetti PR, Raffaelli L. An overview of zirconia ceramics: Basic properties and clinical applications. J Dent 2007;35:819-826.
    • (2007) J Dent , vol.35 , pp. 819-826
    • Manicone, P.F.1    Iommetti, P.R.2    Raffaelli, L.3
  • 37
    • 16344363996 scopus 로고    scopus 로고
    • Influence of surface and heat treatments on the flexural strength of a glass-infiltrated alumina/zirconia-reinforced dental ceramic
    • Guazzato M, Albakry M, Quach L, Swain MV. Influence of surface and heat treatments on the flexural strength of a glass-infiltrated alumina/zirconia-reinforced dental ceramic. Dent Mater 2005;21:454-463.
    • (2005) Dent Mater , vol.21 , pp. 454-463
    • Guazzato, M.1    Albakry, M.2    Quach, L.3    Swain, M.V.4
  • 38
    • 33748596081 scopus 로고    scopus 로고
    • In vitro evaluation of low-temperature aging effects and finishing procedures on the flexural strength and structural stability of Y-TZP dental ceramics
    • Papanagiotou HP, Morgano SM, Giordano RA, Pober R. In vitro evaluation of low-temperature aging effects and finishing procedures on the flexural strength and structural stability of Y-TZP dental ceramics. J Prosthet Dent 2006;96:154-164.
    • (2006) J Prosthet Dent , vol.96 , pp. 154-164
    • Papanagiotou, H.P.1    Morgano, S.M.2    Giordano, R.A.3    Pober, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.