-
2
-
-
0242501489
-
Finite element analysis of the initial stability of ankle arthrodesis with internal fixation: Flat cut versus intact joint contours
-
Alonso Vázquez, A; Lauge-Pedersen, H; Lidgren, L; Taylor, M: Finite element analysis of the initial stability of ankle arthrodesis with internal fixation: flat cut versus intact joint contours. Clin. Biomech. 18:244-53, 2003.
-
(2003)
Clin. Biomech.
, vol.18
, pp. 244-253
-
-
Alonso Vázquez, A.1
Lauge-Pedersen, H.2
Lidgren, L.3
Taylor, M.4
-
3
-
-
3342901935
-
Initial stability of ankle arthrodesis with three-screw fixation. A finite element analysis
-
Alonso Vázquez, A; Lauge-Pedersen, H; Lidgren, L; Taylor, M:Initial stability of ankle arthrodesis with three-screw fixation. A finite element analysis. Clin. Biomech, 19:751-759, 2004.
-
(2004)
Clin. Biomech.
, vol.19
, pp. 751-759
-
-
Alonso Vázquez, A.1
Lauge-Pedersen, H.2
Lidgren, L.3
Taylor, M.4
-
5
-
-
0031977970
-
Tibiotalar arthrodesis in the rheumatoid foot
-
Dereymaeker, GP; van Eygen, P; Driesen, R; De Ferm, A: Tibiotalar arthrodesis in the rheumatoid foot. Clin. Orthop. 349:43-7, 1998.
-
(1998)
Clin. Orthop.
, vol.349
, pp. 43-47
-
-
Dereymaeker, G.P.1
Van Eygen, P.2
Driesen, R.3
De Ferm, A.4
-
6
-
-
0030670940
-
Age variations in the properties of human tibial trabecular bone
-
Ding, M; Dalstra, M; Danielsen, CC; Kabel, J; Hvid, I; Linde, F: Age variations in the properties of human tibial trabecular bone. J. Bone Joint Surg. 79B:995-1002, 1997.
-
(1997)
J. Bone Joint Surg.
, vol.79 B
, pp. 995-1002
-
-
Ding, M.1
Dalstra, M.2
Danielsen, C.C.3
Kabel, J.4
Hvid, I.5
Linde, F.6
-
7
-
-
0028242991
-
A biomechanical evaluation of three forms of internal fixation used in ankle arthrodesis
-
Dohm, MP; Benjamin, JB; Harrison, J; Szivek, JA: A biomechanical evaluation of three forms of internal fixation used in ankle arthrodesis. Foot Ankle Int. 15:297-300, 1994.
-
(1994)
Foot Ankle Int.
, vol.15
, pp. 297-300
-
-
Dohm, M.P.1
Benjamin, J.B.2
Harrison, J.3
Szivek, J.A.4
-
8
-
-
0031968788
-
Ankle arthrodesis in patients with rheumatoid arthritis
-
Felix, NA; Kitaoka, HB: Ankle arthrodesis in patients with rheumatoid arthritis. Clin. Orthop. 349:58-64, 1998.
-
(1998)
Clin. Orthop.
, vol.349
, pp. 58-64
-
-
Felix, N.A.1
Kitaoka, H.B.2
-
9
-
-
0028362330
-
A biomechanical comparative analysis of two techniques for tibiotalar arthrodesis
-
Friedman, RL; Glisson, RR; Nunley, JA: A biomechanical comparative analysis of two techniques for tibiotalar arthrodesis. Foot Ankle Int. 15:301-5, 1994.
-
(1994)
Foot Ankle Int.
, vol.15
, pp. 301-305
-
-
Friedman, R.L.1
Glisson, R.R.2
Nunley, J.A.3
-
10
-
-
0028034777
-
Effects of bone mineral density on pedicle screw fixation
-
Halvorson, TL; Kelley, LA; Thomas, KA; Whitecloud III, TS; Cook, SD: Effects of bone mineral density on pedicle screw fixation. Spine 19:2415-20, 1994.
-
(1994)
Spine
, vol.19
, pp. 2415-2420
-
-
Halvorson, T.L.1
Kelley, L.A.2
Thomas, K.A.3
Whitecloud III, T.S.4
Cook, S.D.5
-
11
-
-
0023958615
-
Trabecular bone strength at the knee
-
Hvid, I: Trabecular bone strength at the knee. Clin. Orthop. 227:210-21, 1988.
-
(1988)
Clin. Orthop.
, vol.227
, pp. 210-221
-
-
Hvid, I.1
-
12
-
-
0032123274
-
Yield strain behaviour of trabecular bone
-
Kopperdahl, DL; Keaveny, TM: Yield strain behaviour of trabecular bone. J. Biomech. 31:601-8, 1998.
-
(1998)
J. Biomech.
, vol.31
, pp. 601-608
-
-
Kopperdahl, D.L.1
Keaveny, T.M.2
-
13
-
-
0033804579
-
Three-dimensional finite element analysis of glenoid replacement prostheses: A comparison of keeled and pegged anchorage systems
-
Lacroix, D; Murphy, LA; Prendergast, PJ: Three-dimensional finite element analysis of glenoid replacement prostheses: a comparison of keeled and pegged anchorage systems. J. Biomech. Eng. 122:430-6, 2000.
-
(2000)
J. Biomech. Eng.
, vol.122
, pp. 430-436
-
-
Lacroix, D.1
Murphy, L.A.2
Prendergast, P.J.3
-
14
-
-
0036105225
-
Arch-shaped versus flat arthrodesis of the ankle joint: Strength measurements using synthetic cancellous bone
-
Lauge-Pedersen, H; Aspenberg, P; Ryd, L; Tanner, KE: Arch-shaped versus flat arthrodesis of the ankle joint: strength measurements using synthetic cancellous bone. Proc Instn. Mech. Engrs. Part H: J. Eng. in Med. 216:43-9, 2002.
-
(2002)
Proc. Instn. Mech. Engrs. Part H: J. Eng. in Med.
, vol.216
, pp. 43-49
-
-
Lauge-Pedersen, H.1
Aspenberg, P.2
Ryd, L.3
Tanner, K.E.4
-
15
-
-
0032427049
-
Percutaneous ankle arthrodesis in the rheumatoid patient without debridement of the joint
-
Lauge-Pedersen, H; Knutson, K; Rydholm, U: Percutaneous ankle arthrodesis in the rheumatoid patient without debridement of the joint. The Foot 8:226-9, 1998.
-
(1998)
The Foot
, vol.8
, pp. 226-229
-
-
Lauge-Pedersen, H.1
Knutson, K.2
Rydholm, U.3
-
16
-
-
0030951051
-
Composition and mechanical properties of cancellous bone from the femoral head of patients with osteoporosis or osteoarthritis
-
Li, B; Aspden, RM: Composition and mechanical properties of cancellous bone from the femoral head of patients with osteoporosis or osteoarthritis. J. Bone Miner Res. 12:641-51, 1997.
-
(1997)
J. Bone Miner Res.
, vol.12
, pp. 641-651
-
-
Li, B.1
Aspden, R.M.2
-
17
-
-
0030962446
-
Age-related changes in the compressive strength of cancellous bone. The relative importance of changes in density and trabecular architecture
-
McCalden, RW; McGeough, JA; Court-Brown, CM: Age-related changes in the compressive strength of cancellous bone. The relative importance of changes in density and trabecular architecture. J. Bone Joint Surg. 79:421-7, 1997.
-
(1997)
J. Bone Joint Surg.
, vol.79
, pp. 421-427
-
-
McCalden, R.W.1
McGeough, J.A.2
Court-Brown, C.M.3
-
18
-
-
0034036554
-
A biomechanical evaluation of internal fixation for ankle arthrodesis comparing two methods of joint surface preparation
-
Miller, RA; Firoozbakhsh, K; Veitch, AJ: A biomechanical evaluation of internal fixation for ankle arthrodesis comparing two methods of joint surface preparation. Orthopedics 23:457-60, 2000.
-
(2000)
Orthopedics
, vol.23
, pp. 457-460
-
-
Miller, R.A.1
Firoozbakhsh, K.2
Veitch, A.J.3
-
19
-
-
0035055590
-
Dependence of yield strain of human trabecular bone on anatomic site
-
Morgan, EF; Keaveny, TM: Dependence of yield strain of human trabecular bone on anatomic site. J. Biomech 34(Suppl. 1):569-77, 2001.
-
(2001)
J. Biomech.
, vol.34
, Issue.SUPPL. 1
, pp. 569-577
-
-
Morgan, E.F.1
Keaveny, T.M.2
-
20
-
-
0034019820
-
Age-related changes in bone mass, structure and strength - Effects of loading
-
Mosekilde, L: Age-related changes in bone mass, structure and strength - effects of loading. Z Rheumatol. 59(Suppl.1):1-9, 2000.
-
(2000)
Z. Rheumatol.
, vol.59
, Issue.SUPPL. 1
, pp. 1-9
-
-
Mosekilde, L.1
-
21
-
-
0034902624
-
Biomechanical comparison of ankle arthrodesis techniques: Crossed screws vs. blade plate
-
Nasson, S; Shuff, C; Palmer, D; Owen, J; Wayne, J; Carr, J; Adelaar, R; May, D: Biomechanical comparison of ankle arthrodesis techniques: crossed screws vs. blade plate. Foot Ankle Int. 22:575-80, 2001.
-
(2001)
Foot Ankle Int.
, vol.22
, pp. 575-580
-
-
Nasson, S.1
Shuff, C.2
Palmer, D.3
Owen, J.4
Wayne, J.5
Carr, J.6
Adelaar, R.7
May, D.8
-
22
-
-
0028103776
-
Arthrodesis of the ankle. A comparison of two versus three screw fixation in a crossed configuration
-
Ogilvie-Harris, DJ; Fitsialos, D; Hedman, TP: Arthrodesis of the ankle. A comparison of two versus three screw fixation in a crossed configuration. Clin. Orthop. 304:195-9, 1994.
-
(1994)
Clin. Orthop.
, vol.304
, pp. 195-199
-
-
Ogilvie-Harris, D.J.1
Fitsialos, D.2
Hedman, T.P.3
-
23
-
-
0027365874
-
Stability of transpedicle screwing for the osteoporotic spine. An in vitro study of the mechanical stability
-
Okuyama, K; Sato, K; Abe, E; Inaba, H; Shimada, Y; Murai, H: Stability of transpedicle screwing for the osteoporotic spine. An in vitro study of the mechanical stability. Spine 18:2240-5, 1993.
-
(1993)
Spine
, vol.18
, pp. 2240-2245
-
-
Okuyama, K.1
Sato, K.2
Abe, E.3
Inaba, H.4
Shimada, Y.5
Murai, H.6
-
24
-
-
0002299444
-
Technical and biomechanical aspects of screws used for bone surgery
-
Perren, SM; Cordey, J; Baumgart, F; Rahn, BA; Schatzker, J: Technical and biomechanical aspects of screws used for bone surgery. Int. J. of Orthop. Trauma 2:31-48, 1992.
-
(1992)
Int. J. of Orthop. Trauma
, vol.2
, pp. 31-48
-
-
Perren, S.M.1
Cordey, J.2
Baumgart, F.3
Rahn, B.A.4
Schatzker, J.5
-
25
-
-
0027521226
-
Evaluation biomecanique comparative de la stabilite immediate de trois fixateurs dans Parthrodese de la cheville
-
Pilette, S; Huk, OL; Yahia, L; Fowles, JV: Evaluation biomecanique comparative de la stabilite immediate de trois fixateurs dans Parthrodese de la cheville. Ann. Chir. 47:905-11, 1993.
-
(1993)
Ann. Chir.
, vol.47
, pp. 905-911
-
-
Pilette, S.1
Huk, O.L.2
Yahia, L.3
Fowles, J.V.4
-
26
-
-
0037648845
-
The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit: Finite element analysis
-
Polikeit, A; Nolte, LP; Ferguson, S: The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit: finite element analysis. Spine 28:991-6, 2003.
-
(2003)
Spine
, vol.28
, pp. 991-996
-
-
Polikeit, A.1
Nolte, L.P.2
Ferguson, S.3
-
27
-
-
0032079123
-
Computed tomography-based finite element analysis predicts failure loads and fracture patterns for vertebral sections
-
Silva, MJ; Keaveny, TM; Hayes, WC: Computed tomography-based finite element analysis predicts failure loads and fracture patterns for vertebral sections. J. Orthop. Res. 16:300-8, 1998.
-
(1998)
J. Orthop. Res.
, vol.16
, pp. 300-308
-
-
Silva, M.J.1
Keaveny, T.M.2
Hayes, W.C.3
-
29
-
-
0026785687
-
Stability of an ankle arthrodesis fixed by cancellous-bone screws compared with that fixed by an external fixator. A biomechanical study
-
Thordarson, DB; Markolf, K; Cracchiolo, A: Stability of an ankle arthrodesis fixed by cancellous-bone screws compared with that fixed by an external fixator. A biomechanical study. J. Bone Joint Surg. 74-A:1050-5, 1992.
-
(1992)
J. Bone Joint Surg.
, vol.74 A
, pp. 1050-1055
-
-
Thordarson, D.B.1
Markolf, K.2
Cracchiolo, A.3
-
30
-
-
0025195686
-
Arthrodesis of the ankle with cancellous-bone screws and fibular strut graft
-
Thordarson, DB; Markolf, KL; Cracchiolo, A: Arthrodesis of the ankle with cancellous-bone screws and fibular strut graft. J. Bone Joint Surg. 72-A:1359-63, 1990.
-
(1990)
J. Bone Joint Surg.
, vol.72 A
, pp. 1359-1363
-
-
Thordarson, D.B.1
Markolf, K.L.2
Cracchiolo, A.3
-
31
-
-
0028876360
-
Arthroscopic ankle arthrodesis in rheumatoid arthritis
-
Turan, I; Wredmark, T; Felländer-Tsai, L: Arthroscopic ankle arthrodesis in rheumatoid arthritis. Clin. Orthop. 320:110-4, 1995.
-
(1995)
Clin. Orthop.
, vol.320
, pp. 110-114
-
-
Turan, I.1
Wredmark, T.2
Felländer-Tsai, L.3
-
32
-
-
0030856730
-
Stiffness of trabecular bone of the tibial plateau in patients with rheumatoid arthritis of the knee
-
Yang, JP; Bogoch, ER; Woodside, TD; Hearn, TC: Stiffness of trabecular bone of the tibial plateau in patients with rheumatoid arthritis of the knee. J. Arthroplasty 12:798-803, 1997.
-
(1997)
J. Arthroplasty
, vol.12
, pp. 798-803
-
-
Yang, J.P.1
Bogoch, E.R.2
Woodside, T.D.3
Hearn, T.C.4
-
33
-
-
0031973823
-
Changes in the stiffness, strength and toughness of human cortical bone with age
-
Zioupos, P; Currey, JD: Changes in the stiffness, strength and toughness of human cortical bone with age. Bone 22:57-66, 1998.
-
(1998)
Bone
, vol.22
, pp. 57-66
-
-
Zioupos, P.1
Currey, J.D.2
|