메뉴 건너뛰기




Volumn 15, Issue 7, 2004, Pages 379-388

Collateral vessel physiology and functional impact-in vivo assessment of collateral channels

Author keywords

Collateral circulation; Coronary atherosclerosis; Coronary vessels

Indexed keywords

ANGIOGENESIS; ANGIOGRAPHY; BLOOD VESSEL FUNCTION; COLLATERAL CIRCULATION; CORONARY ARTERY ATHEROSCLEROSIS; CORONARY ARTERY BLOOD FLOW; CORONARY ARTERY COLLATERAL CIRCULATION; CORONARY ARTERY PRESSURE; DOPPLER FLOWMETRY; GROWTH STIMULATION; HEART MUSCLE NECROSIS; HUMAN; IN VIVO STUDY; POSITRON EMISSION TOMOGRAPHY; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; REVIEW;

EID: 8444245573     PISSN: 09546928     EISSN: None     Source Type: Journal    
DOI: 10.1097/00019501-200411000-00003     Document Type: Review
Times cited : (4)

References (24)
  • 1
    • 0023851630 scopus 로고
    • Determinants and protective potential of coronary arterial collaterals as assessed by an angioplasty model
    • Rentrop KP, Thornton JC, Feit F, et al. Determinants and protective potential of coronary arterial collaterals as assessed by an angioplasty model. Am J Cardiol 1988; 61:677-684. Left ventricular function and clinical outcome after abrupt coronary closure are determined by an interaction between location of the vessel obstruction and the amount of collateral flow. Lesion severity and extent of function impairment resulting from abrupt coronary closure are inversely related.
    • (1988) Am J Cardiol , vol.61 , pp. 677-684
    • Rentrop, K.P.1    Thornton, J.C.2    Feit, F.3
  • 2
    • 0021923120 scopus 로고
    • Changes in collateral channel filling immediately after controlled coronary artery occlusion by an angioplasty balloon in human subjects
    • Rentrop KP, Cohen M, Blanke H, Phillips RA. Changes in collateral channel filling immediately after controlled coronary artery occlusion by an angioplasty balloon in human subjects. J Am Coll Cardiol 1985; 5: 587-592.
    • (1985) J Am Coll Cardiol , vol.5 , pp. 587-592
    • Rentrop, K.P.1    Cohen, M.2    Blanke, H.3    Phillips, R.A.4
  • 3
    • 0022452791 scopus 로고
    • Limitation of myocardial ischemia by collateral circulation during sudden controlled coronary artery occlusion in human subjects: A prospective study
    • Cohen M, Rentrop KP. Limitation of myocardial ischemia by collateral circulation during sudden controlled coronary artery occlusion in human subjects: A prospective study. Circulation 1986; 74:469-476. This article illustrated the concept of collateral circulation limiting the degree of myocardial ischemia. The severity of the ischemia was inversely related to the degree of collateral circulation.
    • (1986) Circulation , vol.74 , pp. 469-476
    • Cohen, M.1    Rentrop, K.P.2
  • 4
    • 0021711619 scopus 로고
    • Effect of nitroglycerin on coronary collateral flow and pressure during acute coronary occlusion
    • Feldman RL, Joyal M, Conti CR, Pepine CJ. Effect of nitroglycerin on coronary collateral flow and pressure during acute coronary occlusion. Am J Cardiol 1984; 54:958-963.
    • (1984) Am J Cardiol , vol.54 , pp. 958-963
    • Feldman, R.L.1    Joyal, M.2    Conti, C.R.3    Pepine, C.J.4
  • 5
    • 0023194096 scopus 로고
    • Coronary wedge pressure in relation to spontaneously visible and recruitable collaterals
    • Meier B, Luethy P, Finci L, et al. Coronary wedge pressure in relation to spontaneously visible and recruitable collaterals. Circulation 1987; 75: 906-913.
    • (1987) Circulation , vol.75 , pp. 906-913
    • Meier, B.1    Luethy, P.2    Finci, L.3
  • 8
    • 0029045171 scopus 로고
    • Relationship between collateral flow assessed by Doppler guide wire and angiographically collateral grades
    • Yamada T, Okamoto M, Sueda T, Hashimoto M, Kajiyama G. Relationship between collateral flow assessed by Doppler guide wire and angiographically collateral grades. Am Heart J 1995; 130:32-37.
    • (1995) Am Heart J , vol.130 , pp. 32-37
    • Yamada, T.1    Okamoto, M.2    Sueda, T.3    Hashimoto, M.4    Kajiyama, G.5
  • 9
    • 0027158683 scopus 로고
    • Spectral analysis of flow velocity in the contralateral artery during coronary angioplasty: A new method for assessing collateral flow
    • Piek JJ, Koolen JJ, Mettingvan Rijn AC, Bot H, Hoedemaker G, David GK, et al. Spectral analysis of flow velocity in the contralateral artery during coronary angioplasty: a new method for assessing collateral flow. J Am Col Cardiol 1993; 21:1574-1582.
    • (1993) J Am Col Cardiol , vol.21 , pp. 1574-1582
    • Piek, J.J.1    Koolen, J.J.2    Mettingvan Rijn, A.C.3    Bot, H.4    Hoedemaker, G.5    David, G.K.6
  • 10
    • 0033101915 scopus 로고    scopus 로고
    • Quantification of collateral flow in humans: A comparison of angiographic electrocardiographic and hemodynamic variables
    • van Liebergen RAM, Piek JJ, Koch KT, de Winter RJ, Schotborgh CE, Lie KI. Quantification of collateral flow in humans: a comparison of angiographic electrocardiographic and hemodynamic variables. J Am Col Cardiol 1999; 33:670-677.
    • (1999) J Am Col Cardiol , vol.33 , pp. 670-677
    • Van Liebergen, R.A.M.1    Piek, J.J.2    Koch, K.T.3    De Winter, R.J.4    Schotborgh, C.E.5    Lie, K.I.6
  • 11
    • 0032212178 scopus 로고    scopus 로고
    • Coronary collateral quantitation in patients with coronary artery disease using intravascular flow velocity or pressure measurements
    • Seiler C, Fleisch M, Garachemani A, Meier B. Coronary collateral quantitation in patients with coronary artery disease using intravascular flow velocity or pressure measurements. J Am Coll Cardiol 1998; 32: 1272-1279.
    • (1998) J Am Coll Cardiol , vol.32 , pp. 1272-1279
    • Seiler, C.1    Fleisch, M.2    Garachemani, A.3    Meier, B.4
  • 12
    • 0033451926 scopus 로고    scopus 로고
    • Simultaneous intracoronary velocity- and pressure-derived assessment of adenosine-induced collateral hemodynamics in patient with one- to two-vessel coronary artery disease
    • Seiler C, Fleisch M, Billinger M, Meier B. Simultaneous intracoronary velocity- and pressure-derived assessment of adenosine-induced collateral hemodynamics in patient with one- to two-vessel coronary artery disease. J Am Coll Cardiol 1999; 34:1985-1994.
    • (1999) J Am Coll Cardiol , vol.34 , pp. 1985-1994
    • Seiler, C.1    Fleisch, M.2    Billinger, M.3    Meier, B.4
  • 13
    • 0033539531 scopus 로고    scopus 로고
    • Physiologically assessed coronary collateral flow and intracoronary growth factor concentrations in patients with 1 - to 3-vessel coronary artery disease
    • Fleisch M, Billinger M, Eberli F, Garachemani AR, Meier B, Seiler C. Physiologically assessed coronary collateral flow and intracoronary growth factor concentrations in patients with 1 - to 3-vessel coronary artery disease. Circulation 1999; 100:1945-1950.
    • (1999) Circulation , vol.100 , pp. 1945-1950
    • Fleisch, M.1    Billinger, M.2    Eberli, F.3    Garachemani, A.R.4    Meier, B.5    Seiler, C.6
  • 14
    • 0030877356 scopus 로고    scopus 로고
    • Pharmacological modulation of the human collateral vascular resistance in acute and chronic coronary occlusion assessed by intracoronary blood flow velocity analysis in an angioplasty model
    • Piek JJ, van Liebergen RAM, Koch KT, de Winter RJ, Peters RJG, David GK. Pharmacological modulation of the human collateral vascular resistance in acute and chronic coronary occlusion assessed by intracoronary blood flow velocity analysis in an angioplasty model. Circulation 1997; 96: 106-115.
    • (1997) Circulation , vol.96 , pp. 106-115
    • Piek, J.J.1    Van Liebergen, R.A.M.2    Koch, K.T.3    De Winter, R.J.4    Peters, R.J.G.5    David, G.K.6
  • 15
    • 0035205181 scopus 로고    scopus 로고
    • Frequency distribution of collateral flow and factors influencing collateral channel development. Functional collateral channel measurement in 450 patients with coronary artery disease
    • Pohl T, Seiler C, Billinger M, Herren E, Wustmann K, Mehta H, et al. Frequency distribution of collateral flow and factors influencing collateral channel development. Functional collateral channel measurement in 450 patients with coronary artery disease. J Am Coll Cardiol 2001; 38:1872-1878.
    • (2001) J Am Coll Cardiol , vol.38 , pp. 1872-1878
    • Pohl, T.1    Seiler, C.2    Billinger, M.3    Herren, E.4    Wustmann, K.5    Mehta, H.6
  • 16
    • 0029043254 scopus 로고
    • Quantification of recruitable coronary collateral blood flow in conscious humans and its potential to predict future ischemic events
    • Pijls NH, Bech GJ, el Gammal MI, Bonnier HJ, De Bruyne B, Van Gelder B, et al. Quantification of recruitable coronary collateral blood flow in conscious humans and its potential to predict future ischemic events. J Am Coll Cardiol 1995; 25:1522-1528.
    • (1995) J Am Coll Cardiol , vol.25 , pp. 1522-1528
    • Pijls, N.H.1    Bech, G.J.2    El Gammal, M.I.3    Bonnier, H.J.4    De Bruyne, B.5    Van Gelder, B.6
  • 17
    • 0027401951 scopus 로고
    • Experimental basis of determining maximum coronary, myocardial and collateral blood flow by pressure measurements for assessing functional stenosis severity before and after percutaneous transluminal coronary angioplasty
    • Pijls NHJ, van Som AM, Kirkeeide RL, DeBruyne B, Gould KL. Experimental basis of determining maximum coronary, myocardial and collateral blood flow by pressure measurements for assessing functional stenosis severity before and after percutaneous transluminal coronary angioplasty. Circulation 1993; 87:1354-1367.
    • (1993) Circulation , vol.87 , pp. 1354-1367
    • Pijls, N.H.J.1    Van Som, A.M.2    Kirkeeide, R.L.3    DeBruyne, B.4    Gould, K.L.5
  • 18
    • 0037022861 scopus 로고    scopus 로고
    • Validation of collateral fractional flow reserve by myocardial perfusion imaging
    • Matsuo H, Watanabe S, Kadosaki T, Yamaki T, Tanaka S, Miyata S, et al. Validation of collateral fractional flow reserve by myocardial perfusion imaging. Circulation 2002; 105:1060-1065.
    • (2002) Circulation , vol.105 , pp. 1060-1065
    • Matsuo, H.1    Watanabe, S.2    Kadosaki, T.3    Yamaki, T.4    Tanaka, S.5    Miyata, S.6
  • 19
    • 0038372757 scopus 로고    scopus 로고
    • Is there functional collateral flow during vascular occlusion in angiographically normal coronary arteries?
    • Wustman K, Zbinden S, Windecker S, Meier B, Seiler C. Is there functional collateral flow during vascular occlusion in angiographically normal coronary arteries? Circulation 2003; 107:2213-2220.
    • (2003) Circulation , vol.107 , pp. 2213-2220
    • Wustman, K.1    Zbinden, S.2    Windecker, S.3    Meier, B.4    Seiler, C.5
  • 20
    • 0034642326 scopus 로고    scopus 로고
    • Immediate changes of collateral function after successful recanalization of chronic total coronary occlusions
    • Werner GS, Richartz B, Gastmann O, Ferrari M, Figulla H. Immediate changes of collateral function after successful recanalization of chronic total coronary occlusions. Circulation 2000; 102:2959-2965.
    • (2000) Circulation , vol.102 , pp. 2959-2965
    • Werner, G.S.1    Richartz, B.2    Gastmann, O.3    Ferrari, M.4    Figulla, H.5
  • 21
    • 0037162373 scopus 로고    scopus 로고
    • Direct assessment of coronary steal and associated changes of collateral hemodynamics in chronic total coronary occlusions
    • Werner GS, Figulla HR. Direct assessment of coronary steal and associated changes of collateral hemodynamics in chronic total coronary occlusions. Circulation 2002; 106:435-440.
    • (2002) Circulation , vol.106 , pp. 435-440
    • Werner, G.S.1    Figulla, H.R.2
  • 22
    • 0031013892 scopus 로고    scopus 로고
    • Detection of coronary collateral using dipyridamole PET myocardial perfusion imaging with rubidium-82
    • Garza D, Tosh A, Roberti R, Dalal P, Reimers C, Ongseng F, et al. Detection of coronary collateral using dipyridamole PET myocardial perfusion imaging with rubidium-82. J Nucl Med 1997; 38:39-43.
    • (1997) J Nucl Med , vol.38 , pp. 39-43
    • Garza, D.1    Tosh, A.2    Roberti, R.3    Dalal, P.4    Reimers, C.5    Ongseng, F.6
  • 24
    • 0027158683 scopus 로고
    • Spectral Analysis of flow velocity in the contralateral artery during coronary angioplasty: A new method for assessing collateral flow
    • Piek JJ, Koolen JJ, Mettingvan Rijn AC, Bot H, Hoedemaker G, David GK, Dunning AJ, et al. Spectral Analysis of flow velocity in the contralateral artery during coronary angioplasty: a new method for assessing collateral flow. J Am Coll Cardiol 1993; 21:1574-1582.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 1574-1582
    • Piek, J.J.1    Koolen, J.J.2    Mettingvan Rijn, A.C.3    Bot, H.4    Hoedemaker, G.5    David, G.K.6    Dunning, A.J.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.