메뉴 건너뛰기




Volumn 54, Issue 12, 2011, Pages 1269-1276

Radiation exposure and its reduction in the fluoroscopic examination and fluoroscopy-guided interventional radiology

Author keywords

Fluoroscopy; Interventional radiography; Radiation dosage; Radiation monitoring; Radiation skin injury

Indexed keywords

CANCER RISK; COMPUTER ASSISTED TOMOGRAPHY; CORNEA INJURY; DIAGNOSTIC IMAGING; FLUOROSCOPY; HUMAN; INTERVENTIONAL RADIOLOGY; MINIMALLY INVASIVE PROCEDURE; PRACTICE GUIDELINE; RADIATION DOSE; RADIATION EXPOSURE; RADIATION INJURY; RADIATION PROTECTION; RADIATION RESPONSE; REFERENCE VALUE; REVIEW; RISK REDUCTION; SKIN INJURY;

EID: 84255199369     PISSN: 19758456     EISSN: None     Source Type: Journal    
DOI: 10.5124/jkma.2011.54.12.1269     Document Type: Review
Times cited : (10)

References (24)
  • 1
    • 67649641621 scopus 로고    scopus 로고
    • NCRP report no. 160. Ionizing radiation exposure of the population of the United States, medical exposure: Are we doing less with more, and is there a role for health physicists?
    • Schauer DA, Linton OW. NCRP report no. 160. Ionizing radiation exposure of the population of the United States, medical exposure: are we doing less with more, and is there a role for health physicists? Health Phys 2009;97:1-5.
    • (2009) Health Phys , vol.97 , pp. 1-5
    • Schauer, D.A.1    Linton, O.W.2
  • 2
    • 77449121542 scopus 로고    scopus 로고
    • Fluoroscopically guided interventional procedures: A review of radiation effects on patients' skin and hair
    • Balter S, Hopewell JW, Miller DL, Wagner LK, Zelefsky MJ. Fluoroscopically guided interventional procedures: a review of radiation effects on patients' skin and hair. Radiology 2010;254:326-341.
    • (2010) Radiology , vol.254 , pp. 326-341
    • Balter, S.1    Hopewell, J.W.2    Miller, D.L.3    Wagner, L.K.4    Zelefsky, M.J.5
  • 3
    • 0034989324 scopus 로고    scopus 로고
    • Skin injuries from fluoroscopically guided procedures: Part I, characteristics of radiation injury
    • Koenig TR, Wolff D, Mettler FA, Wagner LK. Skin injuries from fluoroscopically guided procedures: part 1, characteristics of radiation injury. AJR Am J Roentgenol 2001;177:3-11. (Pubitemid 32578043)
    • (2001) American Journal of Roentgenology , vol.177 , Issue.1 , pp. 3-11
    • Koenig, T.R.1    Wolff, D.2    Mettler, F.A.3    Wagner, L.K.4
  • 4
    • 0034979308 scopus 로고    scopus 로고
    • Skin injuries from fluoroscopically guided procedures: Part 2, review of 73 cases and recommendations for minimizing dose delivered to patient
    • Koenig TR, Mettler FA, Wagner LK. Skin injuries from fluoroscopically guided procedures: part 2, review of 73 cases and recommendations for minimizing dose delivered to patient. AJR Am J Roentgenol 2001;177:13-20. (Pubitemid 32578044)
    • (2001) American Journal of Roentgenology , vol.177 , Issue.1 , pp. 13-20
    • Koenig, T.R.1    Mettler, F.A.2    Wagner, L.K.3
  • 5
    • 0034436030 scopus 로고    scopus 로고
    • Avoidance of radiation injuries from medical interventional procedures: ICRP Publication 85
    • DOI 10.1016/S0146-6453(01)00004-5, PII S0146645301000045
    • Valentin J. Avoidance of radiation injuries from medical interventional procedures. Ann ICRP 2000;30:7-67. (Pubitemid 32664097)
    • (2000) Annals of the ICRP , vol.30 , Issue.2 , pp. 7-67
    • Valentin, J.1
  • 6
    • 47249166093 scopus 로고    scopus 로고
    • Effective doses in radiology and diagnostic nuclear medicine: A catalog
    • Mettler FA Jr, Huda W, Yoshizumi TT, Mahesh M. Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology 2008;248:254-263.
    • (2008) Radiology , vol.248 , pp. 254-263
    • Mettler Jr., F.A.1    Huda, W.2    Yoshizumi, T.T.3    Mahesh, M.4
  • 7
    • 77955636742 scopus 로고    scopus 로고
    • Measuring and monitoring radiation dose during fluoroscopically guided procedures
    • Jaco JW, Miller DL. Measuring and monitoring radiation dose during fluoroscopically guided procedures. Tech Vasc Interv Radiol 2010;13:188-193.
    • (2010) Tech Vasc Interv Radiol , vol.13 , pp. 188-193
    • Jaco, J.W.1    Miller, D.L.2
  • 8
    • 2342453173 scopus 로고    scopus 로고
    • Comparison of effective doses obtained from dose-area product and air kerma measurements in interventional radiology
    • DOI 10.1259/bjr/29942833
    • Bor D, Sancak T, Olgar T, Elcim Y, Adanali A, Sanlidilek U, Akyar S. Comparison of effective doses obtained from dose-area product and air kerma measurements in interventional radiology. Br J Radiol 2004;77:315-322. (Pubitemid 38579116)
    • (2004) British Journal of Radiology , vol.77 , Issue.916 , pp. 315-322
    • Bor, D.1    Sancak, T.2    Olgar, T.3    Elcim, Y.4    Adanali, A.5    Sanlidilek, U.6    Akyar, S.7
  • 9
    • 2642638770 scopus 로고    scopus 로고
    • Estimation of effective dose in some digital angiographic and interventional procedures
    • Ruiz Cruces R, Garcia-Granados J, Diaz Romero FJ, Hernandez Armas J. Estimation of effective dose in some digital angiographic and interventional procedures. Br J Radiol 1998;71:42-47. (Pubitemid 28058472)
    • (1998) British Journal of Radiology , vol.71 , Issue.JAN. , pp. 42-47
    • Ruiz, C.R.1    Garcia-Granados, J.2    Diaz, R.F.J.3    Hernandez, A.J.4
  • 10
    • 0031885073 scopus 로고    scopus 로고
    • A study of patient radiation doses in interventional radiological procedures
    • McParland BJ. A study of patient radiation doses in interven-tional radiological procedures. Br J Radiol 1998;71:175-185. (Pubitemid 28075832)
    • (1998) British Journal of Radiology , vol.71 , Issue.FEB. , pp. 175-185
    • McParland, B.J.1
  • 12
    • 0029021158 scopus 로고
    • Patient and staff dosimetry in neuroradiological procedures
    • Marshall NW, Noble J, Faulkner K. Patient and staff dosimetry in neuroradiological procedures. Br J Radiol 1995;68:495-501.
    • (1995) Br J Radiol , vol.68 , pp. 495-501
    • Marshall, N.W.1    Noble, J.2    Faulkner, K.3
  • 16
    • 73949086433 scopus 로고    scopus 로고
    • Reference levels for patient radiation doses in interventional radiology: Proposed initial values for U.S. practice
    • Miller DL, Kwon D, Bonavia GH. Reference levels for patient radiation doses in interventional radiology: proposed initial values for U.S. practice. Radiology 2009;253:753-764.
    • (2009) Radiology , vol.253 , pp. 753-764
    • Miller, D.L.1    Kwon, D.2    Bonavia, G.H.3
  • 18
    • 77955619638 scopus 로고    scopus 로고
    • Operator shielding: How and why
    • Schueler BA. Operator shielding: how and why. Tech Vasc Interv Radiol 2010;13:167-171.
    • (2010) Tech Vasc Interv Radiol , vol.13 , pp. 167-171
    • Schueler, B.A.1
  • 19
    • 0003488301 scopus 로고
    • National Council on Radiation Protection and Managements. Bethesda: National Council on Radiation Protection and Measurements
    • National Council on Radiation Protection and Managements. Limitation of exposure to ionizaing radiation: NCRP report no. 116. Bethesda: National Council on Radiation Protection and Measurements; 1993.
    • (1993) Limitation of Exposure to Ionizaing Radiation: NCRP Report No. 116
  • 21
    • 0031797811 scopus 로고    scopus 로고
    • Is brain cancer an occupational disease of cardiologists?
    • Finkelstein MM. Is brain cancer an occupational disease of cardiologists? Can J Cardiol 1998;14:1385-1388. (Pubitemid 28552367)
    • (1998) Canadian Journal of Cardiology , vol.14 , Issue.11 , pp. 1385-1388
    • Finkelstein, M.M.1
  • 22
    • 0016608516 scopus 로고
    • The current mortality rates of radiologists and other physician specialists: Specific causes of death
    • Matanoski GM, Seltser R, Sartwell PE, Diamond EL, Elliott EA. The current mortality rates of radiologists and other physician specialists: specific causes of death. Am J Epide-miol 1975;101:199-210.
    • (1975) Am J Epide-miol , vol.101 , pp. 199-210
    • Matanoski, G.M.1    Seltser, R.2    Sartwell, P.E.3    Diamond, E.L.4    Elliott, E.A.5
  • 23
    • 84855822145 scopus 로고    scopus 로고
    • International Atomic Energy Agency Radiation Protection of Patients. [Internet]. Vienna: International Atomic Energy Agency [cited 2011 Nov 18]. Available from
    • International Atomic Energy Agency Radiation Protection of Patients. 10 Pearls: radiation protection of patients in fluoroscopy [Internet]. Vienna: International Atomic Energy Agency [cited 2011 Nov 18]. Available from: https://rpop.iaea.org/RPOP/RPoP/Content/Documents/Whitepapers/ poster-patient-radiation-protection.pdf.
    • 10 Pearls: Radiation Protection of Patients in Fluoroscopy
  • 24
    • 84855822145 scopus 로고    scopus 로고
    • International Atomic Energy Agency Radiation Protection of Patients. [Internet]. Vienna: International Atomic Energy Agency [cited 2011 Nov 18]. Available from
    • International Atomic Energy Agency Radiation Protection of Patients. 10 Pearls: radiation protection of staff in fluoroscopy [Internet]. Vienna: International Atomic Energy Agency [cited 2011 Nov 18]. Available from: https://rpop.iaea.org/RPOP/RPoP/Content/Documents/Whitepapers/ poster-staff-radiation-protection.pdf.
    • 10 Pearls: Radiation Protection of Staff in Fluoroscopy


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.