메뉴 건너뛰기




Volumn 46, Issue 12, 2011, Pages 1646-1649

Changes in the phytoremediation potential of indoor plants with exposure to toluene

Author keywords

Health; VOCs; volatile organic compounds

Indexed keywords


EID: 84255196021     PISSN: 00185345     EISSN: None     Source Type: Journal    
DOI: 10.21273/hortsci.46.12.1646     Document Type: Article
Times cited : (33)

References (22)
  • 2
    • 0002865424 scopus 로고    scopus 로고
    • ATSDR, Agency for Toxic Substance and isease Registry, Atlanta, GA
    • ATSDR. 2000. Toxicological profile for toluene. Agency for Toxic Substance and isease Registry, Atlanta, GA.
    • (2000) Toxicological Profile For Toluene
  • 3
    • 84855851974 scopus 로고    scopus 로고
    • National report on human exposure to environmental chemicals
    • CDC
    • CDC. 2010. National report on human exposure to environmental chemicals. Toluene. Centers for Disease Control and Prevention. http://www.doc.cdc.gov/exposurereport/data_tables/Toluene_ ChemicalInformation.html.
    • (2010) Toluene. Centers For Disease Control and Prevention
  • 4
    • 69849100165 scopus 로고    scopus 로고
    • Indoor air pollution of volatile organic compounds- Indoor/outdoor concentrations, sources and exposures
    • Chikara, H., S. Iwamoto, and T. Yoshimura. 2009. Indoor air pollution of volatile organic compounds- Indoor/outdoor concentrations, sources and exposures. Nippon Eiseigaku Zasshi 64: 683-688.
    • (2009) Nippon Eiseigaku Zasshi , vol.64 , pp. 683-688
    • Chikara, H.1    Iwamoto, S.2    Yoshimura, T.3
  • 5
    • 84922686031 scopus 로고    scopus 로고
    • Effect of bacterial population from rhizosphere of various foliage plants on removal of indoor volatile organic compounds
    • Chun, S.-C., M.H. Yoo, Y.S. Moon, M.H. Shin, K.-C. Son, I.-M. Chung, and S.J. Kays. 2010. Effect of bacterial population from rhizosphere of various foliage plants on removal of indoor volatile organic compounds. Kor. J. Hort. Sci. Technol. 28:476-483.
    • (2010) Kor. J. Hort. Sci. Technol , vol.28 , pp. 476-483
    • Chun, S.-C.1    Yoo, M.H.2    Moon, Y.S.3    Shin, M.H.4    Son, K.-C.5    Chung, I.-M.6    Kays, S.J.7
  • 8
    • 84855572548 scopus 로고
    • Quality and control. Prentice Hall, Englewood Cliffs, N.J. Japanese Ministry of Health, Labour and Welfare. 2000
    • Hines, A.L., T.K. Ghosh, S.K. Loylka, and R.C. Warder, Jr. 1993. Indoor air: Quality and control. Prentice Hall, Englewood Cliffs, N.J. Japanese Ministry of Health, Labour and Welfare. 2000. http://www.mhlw.go.jp/houdou/2002/02/ho208-3.html.
    • (1993) Indoor Air
    • Hines, A.L.1    Ghosh, T.K.2    Loylka, S.K.3    Warder, R.C.4
  • 9
    • 84922685570 scopus 로고    scopus 로고
    • Effects of growing media and exposure frequency on the volatile formaldehyde removal in potted Epipremnum aureum.Kor
    • Kil, M.J., K.J. Kim, C.H. Pak, H.H. Kim, and Y.W. Lim. 2008. Effects of growing media and exposure frequency on the volatile formaldehyde removal in potted Epipremnum aureum.Kor. J. Hort. Sci. Technol 26:325-330.
    • (2008) J. Hort. Sci. Technol , vol.26 , pp. 325-330
    • Kil, M.J.1    Kim, K.J.2    Pak, C.H.3    Kim, H.H.4    Lim, Y.W.5
  • 11
    • 84922686170 scopus 로고    scopus 로고
    • Determination of the efficiency of formaldehyde removal according to the percentage volume of pot plants occupying a room
    • Kim, K.J., M.J. Kil, M.I. Jeong, H.D. Kim, E.H. Yoo, S.J. Jeong, C.H. Pak, and K.C. Son. 2009. Determination of the efficiency of formaldehyde removal according to the percentage volume of pot plants occupying a room. Kor. J. Hort. Sci. Technol. 27:305-311.
    • (2009) Kor. J. Hort. Sci. Technol , vol.27 , pp. 305-311
    • Kim, K.J.1    Kil, M.J.2    Jeong, M.I.3    Kim, H.D.4    Yoo, E.H.5    Jeong, S.J.6    Pak, C.H.7    Son, K.C.8
  • 12
    • 47749122574 scopus 로고    scopus 로고
    • Efficiency of volatile formaldehyde removal by indoor plants: Contribution of aerial plant parts versus the root-zone
    • Kim, K.J., M.J. Kil, J.S. Song, E.H. Yoo, K.C. Son, nd S.J. Kays. 2008. Efficiency of volatile formaldehyde removal by indoor plants: Contribution of aerial plant parts versus the root-zone. J. Amer. Soc. Hort. Sci. 133:521-526.
    • (2008) J. Amer. Soc. Hort. Sci , vol.133 , pp. 521-526
    • Kim, K.J.1    Kil, M.J.2    Song, J.S.3    Yoo, E.H.4    Son, K.C.5    Kays nd, S.J.6
  • 13
    • 84255174127 scopus 로고    scopus 로고
    • Recommended standards for indoor air quality for new apartments
    • Korean Ministry of Environment, Green Korea, Ministry of Environment, Republic of Korea Seoul, Korea
    • Korean Ministry of Environment. 2006. Recommended standards for indoor air quality for new apartments. Green Korea, Ministry of Environment, Republic of Korea, Seoul, Korea. p. 59-60.
    • (2006) Ministry of Environment , pp. 59-60
  • 14
    • 84855614037 scopus 로고    scopus 로고
    • NOHSC, 2000, NTP Toxicology and carcinogenesis studies of toluene in F344/N rats and B6C3F1 mice (inhalation studies). Technical Rept. Series No. 371. National Toxicology Program, National Institutes of Health, U.S. Department of Health and Human Service, Public Health Service, Research Triangle Park, NC
    • NOHSC. 2001. Air toxics and indoor air quality in Australia. National Occupational Health and Safety Commission. http://www.environment.gov.au/atmosphere/airquality/publications/sok/toluene.html. 2000. NTP Toxicology and carcinogenesis studies of toluene in F344/N rats and B6C3F1 mice (inhalation studies). Technical Rept. Series No. 371. National Toxicology Program, National Institutes of Health, U.S. Department of Health and Human Service, Public Health Service, Research Triangle Park, NC.
    • (2001) Air Toxics and Indoor Air Quality In Australia. National Occupational Health and Safety Commission
  • 15
    • 4444383529 scopus 로고    scopus 로고
    • Removal of benzene by the indoor plant/substrate microcosm and implications for air quality
    • Orwell, R., R. Wood, J. Tarran, F. Torpy, and M. Burchett. 2004. Removal of benzene by the indoor plant/substrate microcosm and implications for air quality. Water Soil and Air Pollution 157:193-207.
    • (2004) Water Soil and Air Pollution , vol.157 , pp. 193-207
    • Orwell, R.1    Wood, R.2    Tarran, J.3    Torpy, F.4    Burchett, M.5
  • 16
    • 0037374714 scopus 로고    scopus 로고
    • Volatile organic compounds concentrations in residential indoor and outdoor and its personal exposure in Korea
    • Son, B., P. Breysse, and W. Yang. 2003. Volatile organic compounds concentrations in residential indoor and outdoor and its personal exposure in Korea. Environ. Int. 29:79-85.
    • (2003) Environ Int , vol.29 , pp. 79-85
    • Son, B.1    Breysse, P.2    Yang, W.3
  • 17
    • 33746338216 scopus 로고    scopus 로고
    • Effects of foliage plants and potting soil on the absorption and adsorption of indoor air pollutants
    • Son, K.C., S.H. Lee, S.G. Seo, and J.E. Song. 2000. Effects of foliage plants and potting soil on the absorption and adsorption of indoor air pollutants. J. Korean Soc. Hort. Sci. 41:305- 310.
    • (2000) J. Korean Soc. Hort. Sci , vol.41 , pp. 305-310
    • Son, K.C.1    Lee, S.H.2    Seo, S.G.3    Song, J.E.4
  • 20
    • 0002944995 scopus 로고
    • Plants and soil microorganisms: Removal of formaldehyde, xylene, and ammonia from the indoor environment
    • Wolverton, B.C. and J.D. Wolverton. 1993. Plants and soil microorganisms: Removal of formaldehyde, xylene, and ammonia from the indoor environment. J. Miss. Acad. Sci. 38:11-15.
    • (1993) J. Miss. Acad. Sci , vol.38 , pp. 11-15
    • Wolverton, B.C.1    Wolverton, J.D.2
  • 21
    • 0036163402 scopus 로고    scopus 로고
    • Potted-plant/growth media interactions and capacities for removal of volatiles from indoor air
    • Wood, R.A., R.L. Orwell, J. Tarran, F. Torpy, and M. Burchett. 2002. Potted-plant/growth media interactions and capacities for removal of volatiles from indoor air. J. Hortic. Sci. Biotechnol. 77:120-129.
    • (2002) J. Hortic. Sci. Biotechnol , vol.77 , pp. 120-129
    • Wood, R.A.1    Orwell, R.L.2    Tarran, J.3    Torpy, F.4    Burchett, M.5
  • 22
    • 70350020566 scopus 로고    scopus 로고
    • Screening indoor plants for volatile organic pollutant removal efficiency
    • Yang, D.S., S.V. Pennisi, K.C. Son, and S.J. Kays. 2009. Screening indoor plants for volatile organic pollutant removal efficiency. HortScience 44:1377-1381.
    • (2009) HortScience , vol.44 , pp. 1377-1381
    • Yang, D.S.1    Pennisi, S.V.2    Son, K.C.3    Kays, S.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.