메뉴 건너뛰기




Volumn 19, Issue 1, 2012, Pages 47-54

Contribution of ultrasound in the assessment of nerve diseases

Author keywords

Electrodiagnosis; Peripheral neuropaties; Routine practice; Ultrasound

Indexed keywords

ARTICLE; CARPAL TUNNEL SYNDROME; CUBITAL TUNNEL SYNDROME; ELECTRODIAGNOSIS; ELECTROMYOGRAM; FEMORAL NEUROPATHY; HUMAN; MAJOR CLINICAL STUDY; NERVE CONDUCTION; NEUROPHYSIOLOGY; NUCLEAR MAGNETIC RESONANCE IMAGING; PERIPHERAL NEUROPATHY; PERONEAL NEUROPATHY; PRIORITY JOURNAL; TARSAL TUNNEL SYNDROME; THORAX OUTLET SYNDROME; ULTRASOUND;

EID: 84155168072     PISSN: 13515101     EISSN: 14681331     Source Type: Journal    
DOI: 10.1111/j.1468-1331.2011.03421.x     Document Type: Article
Times cited : (84)

References (24)
  • 1
    • 42749085374 scopus 로고    scopus 로고
    • From square to cube: ultrasound as a natural complement of neurophysiology
    • Padua L, Martinoli C. From square to cube: ultrasound as a natural complement of neurophysiology. Clin Neurophysicol 2008; 119: 1217-1218.
    • (2008) Clin Neurophysicol , vol.119 , pp. 1217-1218
    • Padua, L.1    Martinoli, C.2
  • 7
    • 34248222813 scopus 로고    scopus 로고
    • Contribution of ultrasound in a neurophysiological lab in diagnosis nerve impairment: A one year systematic assessment
    • Padua L, Aprile I, Pazzaglia C, et al. Contribution of ultrasound in a neurophysiological lab in diagnosis nerve impairment: A one year systematic assessment. Clin Neurophysiol 2007; 118: 1410-1416.
    • (2007) Clin Neurophysiol , vol.118 , pp. 1410-1416
    • Padua, L.1    Aprile, I.2    Pazzaglia, C.3
  • 8
    • 34248153921 scopus 로고    scopus 로고
    • The four horsemen of the oscilloscope: dynamic ultrasound, static ultrasound, electromyography and nerve conduction studies
    • Walker FO. The four horsemen of the oscilloscope: dynamic ultrasound, static ultrasound, electromyography and nerve conduction studies. Clin Neurophysiol 2007; 118: 1177-1178.
    • (2007) Clin Neurophysiol , vol.118 , pp. 1177-1178
    • Walker, F.O.1
  • 10
    • 2942724391 scopus 로고    scopus 로고
    • High-resolution sonography of the peripheral nervous system - a review of the literature
    • Beekman R, Visser LH. High-resolution sonography of the peripheral nervous system - a review of the literature. Eur J Neurol 2004; 11: 305-314.
    • (2004) Eur J Neurol , vol.11 , pp. 305-314
    • Beekman, R.1    Visser, L.H.2
  • 11
    • 0030810239 scopus 로고    scopus 로고
    • AAEM minimonograph #26: the electrodiagnosis of carpal tunnel syndrome. American Association of Electrodiagnostic Medicine
    • Stevens JC. AAEM minimonograph #26: the electrodiagnosis of carpal tunnel syndrome. American Association of Electrodiagnostic Medicine. Muscle Nerve 1997; 20: 1477-1486.
    • (1997) Muscle Nerve , vol.20 , pp. 1477-1486
    • Stevens, J.C.1
  • 13
    • 44949118375 scopus 로고    scopus 로고
    • IN-RATIO: a new test to increase diagnostic sensitivity in ulnar nerve entrapment at elbow
    • Caliandro P, Foschini M, Pazzaglia C, et al. IN-RATIO: a new test to increase diagnostic sensitivity in ulnar nerve entrapment at elbow. Clin Neurophysiol 2008; 119: 1600-1606.
    • (2008) Clin Neurophysiol , vol.119 , pp. 1600-1606
    • Caliandro, P.1    Foschini, M.2    Pazzaglia, C.3
  • 14
    • 0025764311 scopus 로고
    • AAEM minimonograph #11: needle examination in clinical electromyography
    • Daube JR. AAEM minimonograph #11: needle examination in clinical electromyography. Muscle Nerve 1991; 14: 685-700.
    • (1991) Muscle Nerve , vol.14 , pp. 685-700
    • Daube, J.R.1
  • 16
    • 0036105127 scopus 로고    scopus 로고
    • Sonography of the median nerve in Charcot-Marie-Tooth disease
    • Martinoli C, Schenone A, Bianchi S, et al. Sonography of the median nerve in Charcot-Marie-Tooth disease. AJR Am J Roentgenol 2002; 178: 1553-1556.
    • (2002) AJR Am J Roentgenol , vol.178 , pp. 1553-1556
    • Martinoli, C.1    Schenone, A.2    Bianchi, S.3
  • 17
    • 0036724724 scopus 로고    scopus 로고
    • Sonographic detection of diffuse peripheral nerve enlargement in hereditary neuropathy with liability to pressure palsies
    • Beekman R, Visser LH. Sonographic detection of diffuse peripheral nerve enlargement in hereditary neuropathy with liability to pressure palsies. J Clin Ultrasound 2002; 30: 433-436.
    • (2002) J Clin Ultrasound , vol.30 , pp. 433-436
    • Beekman, R.1    Visser, L.H.2
  • 19
    • 37749000875 scopus 로고    scopus 로고
    • High-resolution sonography versus EMG in the diagnosis of carpal tunnel syndrome
    • Visser LH, Smidt MH, Lee ML. High-resolution sonography versus EMG in the diagnosis of carpal tunnel syndrome. J Neurol Neurosurg Psychiatry 2008; 79: 63-67.
    • (2008) J Neurol Neurosurg Psychiatry , vol.79 , pp. 63-67
    • Visser, L.H.1    Smidt, M.H.2    Lee, M.L.3
  • 20
    • 70349745851 scopus 로고    scopus 로고
    • High-resolution ultrasonography in evaluating peripheral nerve entrapment and trauma
    • Koenig RW, Pedro MT, Heinen CP, et al. High-resolution ultrasonography in evaluating peripheral nerve entrapment and trauma. Neurosurg Focus 2009; 26: E13.
    • (2009) Neurosurg Focus , vol.26
    • Koenig, R.W.1    Pedro, M.T.2    Heinen, C.P.3
  • 21
    • 4043083571 scopus 로고    scopus 로고
    • Traumatic neuroma diagnosed by ultrasonography
    • Hobson-Webb LD, Walker FO. Traumatic neuroma diagnosed by ultrasonography. Arch Neurol 2004; 61: 1322-1323.
    • (2004) Arch Neurol , vol.61 , pp. 1322-1323
    • Hobson-Webb, L.D.1    Walker, F.O.2
  • 22
    • 42749083911 scopus 로고    scopus 로고
    • The ultrasonographic wrist-to-forearm median nerve area ratio in carpal tunnel syndrome
    • Hobson-Webb LD, Massey JM, Juel VC, Sanders DB. The ultrasonographic wrist-to-forearm median nerve area ratio in carpal tunnel syndrome. Clin Neurophysiol 2008; 119: 1353-1357.
    • (2008) Clin Neurophysiol , vol.119 , pp. 1353-1357
    • Hobson-Webb, L.D.1    Massey, J.M.2    Juel, V.C.3    Sanders, D.B.4
  • 23
    • 78651298896 scopus 로고    scopus 로고
    • High-resolution ultrasonography in the diagnosis and intraoperative management of peripheral nerve lesions
    • Lee FC, Singh H, Nazarian LN, Ratliff JK. High-resolution ultrasonography in the diagnosis and intraoperative management of peripheral nerve lesions. J Neurosurg 2011; 114: 206-211.
    • (2011) J Neurosurg , vol.114 , pp. 206-211
    • Lee, F.C.1    Singh, H.2    Nazarian, L.N.3    Ratliff, J.K.4
  • 24
    • 76649096656 scopus 로고    scopus 로고
    • Atypical double nerve lesion after humeral fracture: diagnosis by ultrasound
    • Liotta G, Granata G, Librante A, et al. Atypical double nerve lesion after humeral fracture: diagnosis by ultrasound. Muscle Nerve 2010; 41: 287-288.
    • (2010) Muscle Nerve , vol.41 , pp. 287-288
    • Liotta, G.1    Granata, G.2    Librante, A.3