메뉴 건너뛰기




Volumn , Issue , 2011, Pages 1447-1450

Online EEG channel weighting for detection of seizures in the neonate

Author keywords

[No Author keywords available]

Indexed keywords

CLASSIFICATION SCHEME; DATA SETS; NEONATAL SEIZURE; ON-THE-FLY; PROBABILISTIC FRAMEWORK; RESEARCH GROUPS; TIME-VARYING WEIGHTS; VALIDATION RESULTS;

EID: 84055217217     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2011.6090358     Document Type: Conference Paper
Times cited : (5)

References (16)
  • 2
    • 0036114029 scopus 로고    scopus 로고
    • A computer-aided detection of EEG seizures in infants, a singular-spectrum approach and performance comparison
    • P. Celka, P. Colditz, "A computer-aided detection of EEG seizures in infants, a singular-spectrum approach and performance comparison", IEEE Tran Biomed Eng, v. 49, pp. 455-462, 2002.
    • (2002) IEEE Tran Biomed Eng , vol.49 , pp. 455-462
    • Celka, P.1    Colditz, P.2
  • 4
    • 33751378334 scopus 로고    scopus 로고
    • Automatic seizure detection based on support vector machines with genetic algorithms
    • J. Fan et al., "Automatic seizure detection based on support vector machines with genetic algorithms", in Simulated Evolution and Learning, LNCS, v. 4247, pp. 845-852, 2006.
    • (2006) Simulated Evolution and Learning, LNCS , vol.4247 , pp. 845-852
    • Fan, J.1
  • 5
    • 33751273678 scopus 로고    scopus 로고
    • Robust EEG channel selection across subjects for brain-computer interfaces
    • M. Schröder et al., "Robust EEG channel selection across subjects for brain-computer interfaces", EURASIP J App. Sig. Pr. v.19, 2005.
    • (2005) EURASIP J App. Sig. Pr. , vol.19
    • Schröder, M.1
  • 6
    • 33846903365 scopus 로고    scopus 로고
    • Salient EEG channel selection in brain computer interfaces by mutual information maximization
    • T. Lan et al., "Salient EEG channel selection in brain computer interfaces by mutual information maximization", in Proc. IEEE EMBC, pp. 7064-7067, 2005.
    • (2005) Proc. IEEE EMBC , pp. 7064-7067
    • Lan, T.1
  • 7
    • 2442670435 scopus 로고    scopus 로고
    • Support vector channel selection in BCI
    • T. Lal et al., "Support vector channel selection in BCI", IEEE Tr Biomed Eng, v. 51, i. 6, pp. 1003-1010, 2004.
    • (2004) IEEE Tr Biomed Eng , vol.51 , Issue.6 , pp. 1003-1010
    • Lal, T.1
  • 8
    • 77950938020 scopus 로고    scopus 로고
    • Discriminative channel selection method for the recognition of anticipation related potentials from CCD estimated cortical activity
    • G. Garipelli et al., "Discriminative channel selection method for the recognition of anticipation related potentials from CCD estimated cortical activity", in Proc. IEEE MLSP, p.1-6, 2009.
    • (2009) Proc. IEEE MLSP , pp. 1-6
    • Garipelli, G.1
  • 9
    • 84863734010 scopus 로고    scopus 로고
    • A channel selection method for EEG classification in emotion assessment based on synchronization likelihood
    • K. Ansari-Asl et al., "A channel selection method for EEG classification in emotion assessment based on synchronization likelihood", In Proc. EUSIPCO, pp. 1241-1245, 2007.
    • (2007) Proc. EUSIPCO , pp. 1241-1245
    • Ansari-Asl, K.1
  • 10
    • 33846909761 scopus 로고    scopus 로고
    • Common spatial pattern method for channel selection in motor imagery based brain-computer interface
    • Y. Wang et al., "Common spatial pattern method for channel selection in motor imagery based brain-computer interface", in Proc. IEEE EMBS, pp. 5392-5395, 2005.
    • (2005) Proc. IEEE EMBS , pp. 5392-5395
    • Wang, Y.1
  • 11
    • 78751613317 scopus 로고    scopus 로고
    • EEGbased neonatal seizure detection with support vector machines
    • A. Temko, E. Thomas, W. Marnane, G. Lightbody, G. Boylan, "EEGbased neonatal seizure detection with support vector machines", Clin Neurophysiol, v. 122, i. 3, pp. 464-473, 2011.
    • (2011) Clin Neurophysiol , vol.122 , Issue.3 , pp. 464-473
    • Temko, A.1    Thomas, E.2    Marnane, W.3    Lightbody, G.4    Boylan, G.5
  • 12
    • 78751633678 scopus 로고    scopus 로고
    • Performance assessment for EEG-based neonatal seizure detectors
    • A. Temko, E. Thomas, W. Marnane, G. Lightbody, G. Boylan, "Performance assessment for EEG-based neonatal seizure detectors", Clin Neurophysiol, v. 122, i. 3, pp. 474-482, 2011.
    • (2011) Clin Neurophysiol , vol.122 , Issue.3 , pp. 474-482
    • Temko, A.1    Thomas, E.2    Marnane, W.3    Lightbody, G.4    Boylan, G.5
  • 13
    • 33749249600 scopus 로고    scopus 로고
    • The relationship between precision-recall and ROC curves
    • J. Davis, M. Goadrich, "The Relationship between Precision-Recall and ROC Curves", in Proc. ICML, pp. 233-40, 2006.
    • (2006) Proc. ICML , pp. 233-240
    • Davis, J.1    Goadrich, M.2
  • 14
    • 35148856609 scopus 로고    scopus 로고
    • Sensitivity of amplitude-integrated electroencephalography for neonatal seizure detection
    • R. Shellhaas et al., "Sensitivity of amplitude-integrated electroencephalography for neonatal seizure detection", Pediatrics, v. 120, pp. 770-777, 2007.
    • (2007) Pediatrics , vol.120 , pp. 770-777
    • Shellhaas, R.1
  • 15
    • 34548534041 scopus 로고    scopus 로고
    • Characterization of neonatal seizures by conventional EEG and single-channel EEG
    • R. Shellhaas, R. Clancy, "Characterization of neonatal seizures by conventional EEG and single-channel EEG", Clin Neurophysiol, v. 118, i. 10, pp. 2156-2161, 2007.
    • (2007) Clin Neurophysiol , vol.118 , Issue.10 , pp. 2156-2161
    • Shellhaas, R.1    Clancy, R.2
  • 16
    • 61849179301 scopus 로고    scopus 로고
    • Limitations of single-channel EEG on the forehead for neonatal seizure detection
    • C. Wusthoff et al., "Limitations of single-channel EEG on the forehead for neonatal seizure detection", J Perinatol, v. 29, 2009.
    • (2009) J Perinatol , vol.29
    • Wusthoff, C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.