메뉴 건너뛰기




Volumn 29, Issue , 2012, Pages 573-580

Use of nano-silica to reduce setting time and increase early strength of concretes with high volumes of fly ash or slag

Author keywords

Compressive strength; Fly ash; Heat development; Nano silica; Setting time; Silica fume; Slag

Indexed keywords

CEMENT HYDRATION; CEMENT PASTE; CEMENTITIOUS MATERIALS; DORMANT PERIOD; EARLY STRENGTH; EXPERIMENTAL STUDIES; HEAT DEVELOPMENT; HIGH-VOLUME FLY ASH; MEAN PARTICLE SIZE; NANO-SILICA; SETTING TIME; SLAG CONCRETE; SLAG HYDRATION; STRENGTH DEVELOPMENT;

EID: 84055214010     PISSN: 09500618     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.conbuildmat.2011.11.013     Document Type: Article
Times cited : (409)

References (28)
  • 1
    • 29144475809 scopus 로고    scopus 로고
    • How nanotechnology can change the concrete world
    • K. Sobolev, and M.F. Gutierrez How nanotechnology can change the concrete world Am Ceram Soc Bull 84 10 2005 14 17
    • (2005) Am Ceram Soc Bull , vol.84 , Issue.10 , pp. 14-17
    • Sobolev, K.1    Gutierrez, M.F.2
  • 2
    • 77955280634 scopus 로고    scopus 로고
    • Nanotechnology in concrete - A review
    • F. Sanchez, and K. Sobolev Nanotechnology in concrete - a review Constr Build Mater 24 11 2010 2060 2071
    • (2010) Constr Build Mater , vol.24 , Issue.11 , pp. 2060-2071
    • Sanchez, F.1    Sobolev, K.2
  • 3
    • 33845390846 scopus 로고    scopus 로고
    • 2 addition on properties of hardened cement paste as compared with silica fume
    • DOI 10.1016/j.conbuildmat.2005.09.001, PII S0950061805002837, Fracture, Acoustic Emission and NDE in Concrete (KIFA-4)
    • 2 addition on properties of hardened cement paste as compared with silica fume Constr Build Mater 21 3 2007 539 545 (Pubitemid 44895433)
    • (2007) Construction and Building Materials , vol.21 , Issue.3 , pp. 539-545
    • Qing, Y.1    Zenan, Z.2    Deyu, K.3    Rongshen, C.4
  • 5
    • 1242329200 scopus 로고    scopus 로고
    • Microstructure of cement mortar with nano-particles
    • H. Li, H.-G. Xiao, J. Yuan, and J. Ou Microstructure of cement mortar with nano-particles Composites Part B 35 2 2004 185 189
    • (2004) Composites Part B , vol.35 , Issue.2 , pp. 185-189
    • Li, H.1    Xiao, H.-G.2    Yuan, J.3    Ou, J.4
  • 7
    • 77952396830 scopus 로고    scopus 로고
    • An investigation into the effect of silicon dioxide particle size on the strength of concrete
    • J. Schoepfer, and A. Maji An investigation into the effect of silicon dioxide particle size on the strength of concrete ACI Spec Publ 267 5 2009 45 58
    • (2009) ACI Spec Publ , vol.267 , Issue.5 , pp. 45-58
    • Schoepfer, J.1    Maji, A.2
  • 8
    • 2142651760 scopus 로고    scopus 로고
    • 2
    • 2 Cem Concr Res 34 6 2004 1043 1049
    • (2004) Cem Concr Res , vol.34 , Issue.6 , pp. 1043-1049
    • Li, G.1
  • 9
    • 77952324076 scopus 로고    scopus 로고
    • Enhancing the reactivity of normal and fly ash concrete using colloidal nano-silica
    • A.M. Said, and M.S. Zeidan Enhancing the reactivity of normal and fly ash concrete using colloidal nano-silica ACI Spec Publ 267 7 2009 75 86
    • (2009) ACI Spec Publ , vol.267 , Issue.7 , pp. 75-86
    • Said, A.M.1    Zeidan, M.S.2
  • 11
    • 18144453949 scopus 로고    scopus 로고
    • Accelerating effects of colloidal nano-silica for beneficial calcium-silicate-hydrate formation in cement
    • J. Björnström, A. Martinelli, A. Matic, L. Börjesson, and I. Panas Accelerating effects of colloidal nano-silica for beneficial calcium-silicate-hydrate formation in cement Chem Phys Lett 392 1-3 2004 242 248
    • (2004) Chem Phys Lett , vol.392 , Issue.13 , pp. 242-248
    • Björnström, J.1    Martinelli, A.2    Matic, A.3    Börjesson, L.4    Panas, I.5
  • 13
    • 84555221923 scopus 로고    scopus 로고
    • Standard specification for coal fly ash and raw or dalcined natural pozzolan for use in concrete
    • ASTM C 618
    • ASTM C 618. Standard specification for coal fly ash and raw or dalcined natural pozzolan for use in concrete. Annual Book of ASTM Standards, vol. 04.02; 2008.
    • (2008) Annual Book of ASTM Standards, Vol. 04.02
  • 14
    • 84655172465 scopus 로고    scopus 로고
    • Standard specification for slag cement for use in concrete and mortars
    • ASTM C 989
    • ASTM C 989. Standard specification for slag cement for use in concrete and mortars. Annual Book of ASTM Standards, vol. 04.02; 2010.
    • (2010) Annual Book of ASTM Standards, Vol. 04.02
  • 15
    • 0003333270 scopus 로고    scopus 로고
    • Standard specification for concrete aggregates
    • ASTM C 33
    • ASTM C 33. Standard specification for concrete aggregates. Annual Book of ASTM Standards, vol. 04.02; 2008.
    • (2008) Annual Book of ASTM Standards, Vol. 04.02
  • 16
    • 0006936144 scopus 로고    scopus 로고
    • Standard test method for flow of hydraulic cement mortar
    • ASTM C 1437
    • ASTM C 1437. Standard test method for flow of hydraulic cement mortar. Annual Book of ASTM Standards, vol. 04.01; 2005.
    • (2005) Annual Book of ASTM Standards, Vol. 04.01
  • 17
    • 84859980393 scopus 로고    scopus 로고
    • Standard test method for compressive strength of hydraulic cement mortars (using 2-in or [50-mm] cube specimens)
    • ASTM C 109/C 109M
    • ASTM C 109/C 109M. Standard test method for compressive strength of hydraulic cement mortars (using 2-in or [50-mm] cube specimens). Annual Book of ASTM Standards, vol. 04.01; 2005.
    • (2005) Annual Book of ASTM Standards, Vol. 04.01
  • 18
    • 85059533086 scopus 로고    scopus 로고
    • Testing hardened concrete - Part 3: Compressive strength of test specimens
    • BS EN 12390-3
    • BS EN 12390-3. Testing hardened concrete - Part 3: compressive strength of test specimens. British Standards Institution; 2002.
    • (2002) British Standards Institution
  • 19
    • 74549158359 scopus 로고    scopus 로고
    • Standard test method for time of setting of concrete mixtures by penetration resistance
    • ASTM C 403/C 403M
    • ASTM C 403/C 403M. Standard test method for time of setting of concrete mixtures by penetration resistance. Annual Book of ASTM Standards, vol. 04.02; 2008.
    • (2008) Annual Book of ASTM Standards, Vol. 04.02
  • 20
    • 0012714488 scopus 로고    scopus 로고
    • Standard test method for electrical indication of concrete's ability to resist chloride ion penetration
    • ASTM C 1202
    • ASTM C 1202. Standard test method for electrical indication of concrete's ability to resist chloride ion penetration. Annual Book of ASTM Standards, vol. 04.02; 2008.
    • (2008) Annual Book of ASTM Standards, Vol. 04.02
  • 21
    • 84855941255 scopus 로고    scopus 로고
    • Practice for measuring hydration kinetics of hydraulic cementitious mixtures using isothermal calorimetry
    • ASTM C 1679
    • ASTM C 1679. Practice for measuring hydration kinetics of hydraulic cementitious mixtures using isothermal calorimetry. Annual Book of ASTM Standards, vol. 04.02; 2008.
    • (2008) Annual Book of ASTM Standards, Vol. 04.02
  • 22
  • 25
    • 0021500681 scopus 로고
    • High strength mortars containing condensed silica fume
    • DOI 10.1016/0008-8846(84)90033-4
    • M. Buil, A.M. Paillre, and B. Roussel High strength mortars containing condensed silica fume Cem Concr Res 14 5 1984 693 704 (Pubitemid 14663285)
    • (1984) Cement and Concrete Research , vol.14 , Issue.5 , pp. 693-704
    • Buil, M.1    Paillere, A.M.2    Roussel, B.3
  • 27
    • 0026222388 scopus 로고
    • Effect of silica fume on cement hydration in low porosity cement pastes
    • M.-H. Zhang, and O.E. Gjørv Effect of silica fume on cement hydration in low porosity cement pastes Cem Concr Res 21 5 1991 800 808
    • (1991) Cem Concr Res , vol.21 , Issue.5 , pp. 800-808
    • Zhang, M.-H.1    Gjørv, O.E.2