메뉴 건너뛰기




Volumn , Issue , 2011, Pages 5847-5850

A low-power high-sensitivity CMOS mixed-signal seizure-onset detector

Author keywords

[No Author keywords available]

Indexed keywords

CIRCUITRY IMPLEMENTATION; CMOS PROCESSS; EPILEPTIC PATIENTS; HIGH-SENSITIVITY; LOW POWER; MATLAB TOOLS; MIXED SIGNAL; PARAMETER VALUES; SEIZURE DETECTION; TOTAL POWER DISSIPATION; VALIDATION PHASE; VARIABLE PARAMETERS;

EID: 84055192664     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2011.6091446     Document Type: Conference Paper
Times cited : (1)

References (8)
  • 2
    • 37349050623 scopus 로고    scopus 로고
    • Responsive cortical stimulation for the treatment of epilepsy
    • F. T. Sun, M. J. Morrell, and R. E. Wharen-Jr, "Responsive Cortical Stimulation for the Treatment of Epilepsy," Neurotherapeutics, vol. 5(1), pp. 68-74, 2008.
    • (2008) Neurotherapeutics , vol.5 , Issue.1 , pp. 68-74
    • Sun, F.T.1    Morrell, M.J.2    Wharen Jr., R.E.3
  • 4
    • 77957686139 scopus 로고    scopus 로고
    • The design and hardware implementation of a lowpower real-time seizure detection algorithm
    • S. Raghunathan, S. K. Gupta, M. P. Ward, R. M. Worth, K. Roy, and P. P. Irazoqui, "The design and hardware implementation of a lowpower real-time seizure detection algorithm," J. Neural Eng., vol. 6(5):056005, 2009.
    • (2009) J. Neural Eng. , vol.6 , Issue.5 , pp. 056005
    • Raghunathan, S.1    Gupta, S.K.2    Ward, M.P.3    Worth, R.M.4    Roy, K.5    Irazoqui, P.P.6
  • 5
    • 84055204456 scopus 로고    scopus 로고
    • Epileptic seizure onset detection prior to clinical manifestation
    • M. Tariqus Salam, M. Sawan, and D. K. Nguyen, "Epileptic Seizure Onset Detection Prior to Clinical Manifestation," IEEE EMBC, pp. 1976-1985, 2010.
    • (2010) IEEE EMBC , pp. 1976-1985
    • Tariqus Salam, M.1    Sawan, M.2    Nguyen, D.K.3
  • 6
    • 77749315839 scopus 로고    scopus 로고
    • Epileptic low-voltage fast-activity seizure-onset detector
    • M. Tariqus Salam, M. Sawan, D. K. Nguyen, and A. Hamoui, "Epileptic Low-Voltage Fast-Activity Seizure-Onset Detector," IEEE BioCAS, pp. 169-172, 2009.
    • (2009) IEEE BioCAS , pp. 169-172
    • Tariqus Salam, M.1    Sawan, M.2    Nguyen, D.K.3    Hamoui, A.4
  • 7
    • 0038718680 scopus 로고    scopus 로고
    • A low-power low-noise CMOS amplifier for neural recording applications
    • R. R. Harrison, and C. Charles, "A Low-Power Low-Noise CMOS Amplifier for Neural Recording Applications," IEEE JSSC, vol. 38(6), pp. 958-965, 2003.
    • (2003) IEEE JSSC , vol.38 , Issue.6 , pp. 958-965
    • Harrison, R.R.1    Charles, C.2
  • 8
    • 34047177571 scopus 로고    scopus 로고
    • An integrated CMOS bio-potential amplifier with a feed-forward DC cancellation topology
    • J. Parthasarathy, A. G. Erdman, A. D. Redish, and B. Ziaie, "An Integrated CMOS Bio-potential Amplifier with a Feed-Forward DC Cancellation Topology," IEEE EMBC, pp.2974-2977, 2006.
    • (2006) IEEE EMBC , pp. 2974-2977
    • Parthasarathy, J.1    Erdman, A.G.2    Redish, A.D.3    Ziaie, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.