-
1
-
-
0032605262
-
Knowledge optimization theory and application to point-of-care testing
-
Kost GJ. Knowledge optimization theory and application to point-of-care testing. Stud Health Technol Inform. 1999;62: 189-190.
-
(1999)
Stud Health Technol. Inform.
, vol.62
, pp. 189-190
-
-
Kost, G.J.1
-
2
-
-
0028561959
-
Point-of-care versus central laboratory testing: An economic analysis in an academic medical center
-
discussion 854
-
Tsai WW, Nash DB, Seamonds B, Weir GJ. Point-of-care versus central laboratory testing: An economic analysis in an academic medical center. Clin Ther. 1994;16:898-910, discussion 854.
-
(1994)
Clin. Ther.
, vol.16
, pp. 898-910
-
-
Tsai, W.W.1
Nash, D.B.2
Seamonds, B.3
Weir, G.J.4
-
3
-
-
0028840244
-
Guidelines for point-of-care testing improving patient outcomes
-
Kost GJ. Guidelines for point-of-care testing. Improving patient outcomes. Am J Clin Pathol. 1995;104(Suppl. 1): S111-S127.
-
(1995)
Am. J. Clin. Pathol.
, vol.104
, Issue.1
-
-
Kost, G.J.1
-
4
-
-
0036237357
-
Medical and economic outcomes of point-of-care testing
-
DOI 10.1515/CCLM.2002.040
-
Price CP. Medical and economic outcomes of point-of-care testing. Clin Chem Lab Med. 2002;40:246-251. (Pubitemid 34428853)
-
(2002)
Clinical Chemistry and Laboratory Medicine
, vol.40
, Issue.3
, pp. 246-251
-
-
Price, C.P.1
-
5
-
-
33750098540
-
Poised for growth point-of-care testing
-
Scalise D. Poised for growth. Point-of-care testing. Hosp Health Netw. 2006;80:77-83.
-
(2006)
Hosp. Health Netw.
, vol.80
, pp. 77-83
-
-
Scalise, D.1
-
6
-
-
10244236377
-
Acute renal failure-definition outcome measures animal models fluid therapy and information technology needs: The second international consensus conference of the acute dialysis quality initiative ADQI group
-
10.1186 cc2872
-
Bellomo R, Ronco C, Kellum JA, Mehta RL, Palevsky P. Acute renal failure-Definition, outcome measures, animal models, fluid therapy and information technology needs: The Second International Consensus Conference of the Acute Dialysis Quality Initiative (ADQI) Group. Crit Care. 2004;8: R204-R212, doi: 10.1186/cc2872.
-
(2004)
Crit. Care.
, vol.8
-
-
Bellomo, R.1
Ronco, C.2
Kellum, J.A.3
Mehta, R.L.4
Palevsky, P.5
-
7
-
-
34247235247
-
Laatakin acute kidney injury network: Report of an initiative to improve outcomes in acute kidney injury
-
Mehta RLKJ, Shah SV, Molitoris BA, Ronco C, Warnock DG. LAatAKIN. Acute kidney injury network: Report of an initiative to improve outcomes in acute kidney injury. Crit Care. 2007;11:R31.
-
(2007)
Crit. Care
, vol.11
-
-
Mehta, R.L.K.J.1
Shah, S.V.2
Molitoris, B.A.3
Ronco, C.4
Warnock, D.G.5
-
8
-
-
78649499055
-
A comparison of three methods to estimate baseline creatinine for RIFLE classification
-
Zavada J, Hoste E, Cartin-Ceba R, et al. A comparison of three methods to estimate baseline creatinine for RIFLE classification. Nephrol Dial Transplant. 2010;25:3911-3918.
-
(2010)
Nephrol. Dial. Transplant
, vol.25
, pp. 3911-3918
-
-
Zavada, J.1
Hoste, E.2
Cartin-Ceba, R.3
-
9
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
PII S0140673686908378
-
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307-310. (Pubitemid 16134762)
-
(1986)
Lancet
, vol.1
, Issue.8476
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
10
-
-
0742304359
-
Defining acute renal failure: Physiological principles
-
DOI 10.1007/s00134-003-2078-3
-
Bellomo R, Kellum JA, Ronco C. Defining acute renal failure: Physiological principles. Intensive Care Med. 2004;30:33-37. (Pubitemid 38147105)
-
(2004)
Intensive Care Medicine
, vol.30
, Issue.1
, pp. 33-37
-
-
Bellomo, R.1
Kellum, J.A.2
Ronco, C.3
-
11
-
-
14844325792
-
Creatinine measurement: State of the art in accuracy and interlaboratory harmonization
-
Miller WG, Myers GL, Ashwood ER, et al. Creatinine measurement: State of the art in accuracy and interlaboratory harmonization. Arch Pathol Lab Med. 2005;129:297-304. (Pubitemid 40343981)
-
(2005)
Archives of Pathology and Laboratory Medicine
, vol.129
, Issue.3
, pp. 297-304
-
-
Miller, W.G.1
Myers, G.L.2
Ashwood, E.R.3
Killeen, A.A.4
Wang, E.5
Thienpont, L.M.6
Siekmann, L.7
-
12
-
-
84961471508
-
The accuracy of creatinine methods based on the jaffe reaction: A questionable matter
-
Blijenberg BG, Brouwer HJ. The accuracy of creatinine methods based on the Jaffe reaction: A questionable matter. Eur J Clin Chem Clin Biochem. 1994;32:909-913.
-
(1994)
Eur. J. Clin. Chem. Clin. Biochem.
, vol.32
, pp. 909-913
-
-
Blijenberg, B.G.1
Brouwer, H.J.2
-
13
-
-
0022411543
-
Characterization of creatinine error in ketotic patients. A prospective comparison of alkaline picrate methods with an enzymatic method
-
Gerard SK, Khayam-Bashi H. Characterization of creatinine error in ketotic patients. A prospective comparison of alkaline picrate methods with an enzymatic method. Am J Clin Pathol. 1985;84:659-664. (Pubitemid 16235308)
-
(1985)
American Journal of Clinical Pathology
, vol.84
, Issue.5
, pp. 659-664
-
-
Gerard, S.K.1
Khayam-Bashi, H.2
-
14
-
-
0017933989
-
Bilirubin interference with the kinetic jaffe method for serum creatinine
-
Daugherty NA, Hammond KB, Osberg IM. Bilirubin interference with the kinetic Jaffe method for serum creatinine. Clin Chem. 1978;24:392-393.
-
(1978)
Clin. Chem.
, vol.24
, pp. 392-393
-
-
Daugherty, N.A.1
Hammond, K.B.2
Osberg, I.M.3
-
15
-
-
77953516542
-
Exogenous interferences with jaffe creatinine assays: Addition of sodium dodecyl sulfate to reagent eliminates bilirubin and total protein interference with jaffe methods
-
Srisawasdi P, Chaichanajarernkul U, Teerakanjana N, Vanavanan S, Kroll MH. Exogenous interferences with Jaffe creatinine assays: Addition of sodium dodecyl sulfate to reagent eliminates bilirubin and total protein interference with Jaffe methods. J Clin Lab Anal. 2010;24:123-133.
-
(2010)
J. Clin. Lab. Anal.
, vol.24
, pp. 123-133
-
-
Srisawasdi, P.1
Chaichanajarernkul, U.2
Teerakanjana, N.3
Vanavanan, S.4
Kroll, M.H.5
-
16
-
-
0025778225
-
Use of a synthetic soluble bilirubin derivative to assess interference in creatinine measurements
-
Franzini C, Morelli AM, Cattozzo G. Use of a synthetic soluble bilirubin derivative to assess interference in creatinine measurements. Clin Chem. 1991;37:236-238. (Pubitemid 21892633)
-
(1991)
Clinical Chemistry
, vol.37
, Issue.2
, pp. 236-238
-
-
Franzini, C.1
Morelli, A.M.2
Cattozzo, G.3
-
17
-
-
62149102286
-
Prime time for enzymatic creatinine methods in pediatrics
-
Cobbaert CM, Baadenhuijsen H, Weykamp CW. Prime time for enzymatic creatinine methods in pediatrics. Clin Chem. 2009;55:549-558.
-
(2009)
Clin. Chem.
, vol.55
, pp. 549-558
-
-
Cobbaert, C.M.1
Baadenhuijsen, H.2
Weykamp, C.W.3
-
18
-
-
0028867161
-
Correction of glucose concentration interference on jaffe kinetic creatinine assay in peritoneal dialysis
-
Da Rin G, Amici G, Virga G, Bardin C, Calzavara P, Bocci C. Correction of glucose concentration interference on Jaffe kinetic creatinine assay in peritoneal dialysis. Am J Nephrol. 1995;15:480-487.
-
(1995)
Am. J. Nephrol.
, vol.15
, pp. 480-487
-
-
Da Rin, G.1
Amici, G.2
Virga, G.3
Bardin, C.4
Calzavara, P.5
Bocci, C.6
-
19
-
-
0025255075
-
The need for using an enzymatic colorimetric assay in creatinine determination of peritoneal dialysis solutions
-
Larpent L, Verger C. The need for using an enzymatic colorimetric assay in creatinine determination of peritoneal dialysis solutions. Perit Dial Int. 1990;10:89-92. (Pubitemid 20114213)
-
(1990)
Peritoneal Dialysis International
, vol.10
, Issue.1
, pp. 89-92
-
-
Larpent, L.1
Verger, C.2
-
20
-
-
0028578026
-
Glucose interference in jaffe creatinine method: Effect of calcium from peritoneal dialysate
-
Lo SC, Tsai KS. Glucose interference in Jaffe creatinine method: Effect of calcium from peritoneal dialysate. Clin Chem. 1994;40:2326-2327.
-
(1994)
Clin. Chem.
, vol.40
, pp. 2326-2327
-
-
Lo, S.C.1
Tsai, K.S.2
-
21
-
-
0017714113
-
Positive interference with the Jaffe reaction by cephalosporin antibiotics
-
Swain RR, Briggs SL. Positive interference with the Jaffe reaction by cephalosporin antibiotics. Clin Chem. 1977;23: 1340-1342. (Pubitemid 8110471)
-
(1977)
Clinical Chemistry
, vol.23
, Issue.7
, pp. 1340-1342
-
-
Swain, R.R.1
Briggs, S.L.2
-
22
-
-
0016737446
-
Factors influencing the assay of creatinine
-
Cook JG. Factors influencing the assay of creatinine. Ann Clin Biochem. 1975;12:219-232.
-
(1975)
Ann. Clin. Biochem.
, vol.12
, pp. 219-232
-
-
Cook, J.G.1
-
23
-
-
0019370206
-
Assay of creatinine in serum, with use of Fuller's earth to remove interferents
-
Haeckel R. Assay of creatinine in serum, with use of fuller's earth to remove interferents. Clin Chem. 1981;27: 179-183. (Pubitemid 11189004)
-
(1981)
Clinical Chemistry
, vol.27
, Issue.1
, pp. 179-183
-
-
Haeckel, R.1
Gadsden, R.H.2
Sherwin, J.E.3
-
24
-
-
84945735049
-
Automated enzymatic methods for creatinine measurement with special attention to bilirubin interference
-
Schoenmakers CH, Kuller T, Lindemans J, Blijenberg BG. Automated enzymatic methods for creatinine measurement with special attention to bilirubin interference. Eur J Clin Chem Clin Biochem. 1993;31:861-868. (Pubitemid 24015312)
-
(1993)
European Journal of Clinical Chemistry and Clinical Biochemistry
, vol.31
, Issue.12
, pp. 861-868
-
-
Schoenmakers, C.H.H.1
Kuller, T.2
Lindemans, J.3
Blijenberg, B.G.4
-
25
-
-
84945736974
-
Multicentre evaluation of an enzymatic method for creatinine determination using a sensitive colour reagent
-
Guder WG, Hoffmann GE, Hubbuch A, Poppe WA, Siedel J, Price CP. Multicentre evaluation of an enzymatic method for creatinine determination using a sensitive colour reagent. J Clin Chem Clin Biochem. 1986;24:889-902. (Pubitemid 17187466)
-
(1986)
Journal of Clinical Chemistry and Clinical Biochemistry
, vol.24
, Issue.11
, pp. 889-902
-
-
Guder, W.G.1
Hoffmann, G.E.2
Hubbuch, A.3
-
26
-
-
0026657022
-
A simplified procedure for eliminating the negative interference of bilirubin in the jaffe reaction for creatinine
-
O'Leary N, Pembroke A, Duggan PF. A simplified procedure for eliminating the negative interference of bilirubin in the Jaffe reaction for creatinine. Clin Chem. 1992;38:1749-1751.
-
(1992)
Clin. Chem.
, vol.38
, pp. 1749-1751
-
-
Leary, N.1
Pembroke, A.2
Duggan, P.F.3
-
27
-
-
29744469415
-
Recommendations for improving serum creatinine measurement: A report from the Laboratory Working Group of the National Kidney Disease Education Program
-
DOI 10.1373/clinchem.2005.0525144
-
Myers GL, Miller WG, Coresh J, et al. Recommendations for improving serum creatinine measurement: A report from the Laboratory Working Group of the National Kidney Disease Education Program. Clin Chem. 2006;52:5-18. (Pubitemid 43032461)
-
(2006)
Clinical Chemistry
, vol.52
, Issue.1
, pp. 5-18
-
-
Myers, G.L.1
Miller, W.G.2
Coresh, J.3
Fleming, J.4
Greenberg, N.5
Greene, T.6
Hostetter, T.7
Levey, A.S.8
Panteghini, M.9
Welch, M.10
Eckfeldt, J.H.11
-
28
-
-
64149124285
-
Point of care measurement of plasma creatinine in critically ill patients with acute kidney injury
-
Udy A, O'Donoghue S, D'Intini V, Healy H, Lipman J. Point of care measurement of plasma creatinine in critically ill patients with acute kidney injury. Anaesthesia. 2009;64: 403-407.
-
(2009)
Anaesthesia
, vol.64
, pp. 403-407
-
-
Udy, A.1
O'Donoghue, S.D.2
Intini, V.3
Healy, H.4
Lipman, J.5
-
29
-
-
0030346260
-
Calcium lactate interference in measuring creatinine in peritoneal dialysis fluids by the jaffe kinetic method
-
Amici G, Da Rin G, Bardin C, Gatti PL, Calconi G, Bocci C. Calcium lactate interference in measuring creatinine in peritoneal dialysis fluids by the Jaffe kinetic method. Adv Perit Dial. 1996;12:257-260.
-
(1996)
Adv. Perit. Dial.
, vol.12
, pp. 257-260
-
-
Amici, G.1
Da Rin, G.2
Bardin, C.3
Gatti, P.L.4
Calconi, G.5
Bocci, C.6
|